BPH hydraulic sensor

Load Weighing Devices

BPH hydraulic sensor

BPH hydraulic sensor introduction The BPH sensor is specially designed for hydraulic systems, which is installed between the hydraulic jack and the undercarriage of the cabin. It calculates the weight with maximum accuracy by the pressure…

Catalogs & documents

Use the continuous web edition for reading, search and source-page references. The original file remains available on every document page.

Product information

Specifications

BPH hydraulic sensor

introduction

The BPH sensor is specially designed for hydraulic systems, which is installed between the hydraulic jack and the undercarriage of the cabin. It calculates the weight with maximum accuracy by the pressure applied to the sensor. The capacity of this sensor is 3000 kg (cabin capacity + cabin weight), which is connected to the VK control device by a 5-meter cable, like most of Dinasel's sensors.

It is recommended to use this sensor for cabins with low capacity (up to 10 people). The reason for the superiority of the BPH sensor over other types of sensors is that it does not suffer from errors due to rail friction and mechanical movements, the weight of cables and compensating chains, and other factors that prevent correct measurement, and it is recommended to be installed and used on new elevators. According to the type of hydraulic jack, you can use special sensors (according to the order).

Screen Shot 2017-08-30 at 1.24.48 PM.png

 

Features

 

• Made by Dinasel Spain 

• Special for hydraulic sensors

• European Union standard

• Has 1 year warranty

• 5 years after-sales service

• 24-hour service and support

• Weight measurement and loading restrictions

• Maximum accuracy in weight measurement

• The sensor is installed under the cabin and the controller is installed above the cabin

• Very easy setting (Persian catalog of setting)

• Advanced design to prevent transmission of mechanical vibrations

• Its installation depends on the type of suspension system design is not

 Weight holder inlet during cabin movement

• "Automatic calibration" without the need to perform a step (specific weight) for final adjustment

• It is recommended to be used for the installation and commissioning of new elevators

 

 

Electrical specifications

 

• Can be connected to the VK control device  

• The VK control device has 3 output relays 

• Serial communication capability on the VK device (optional)

• It has 3 indicator lights of the weight range on the VK device (optional)

• Cabin display output on VK device (optional)

• Analog output on VK device (V, 4 to 20 mA 10 to 0) (optional)

• Very easy wiring and adjustment (Persian catalog of adjustment)

• VK controller input power supply (115~230V-AC)

• Nominal frequency 50 to 60 Hz

• Contact relays V - 3 amps 250

• The input voltage of the holder is 24V ~ 230V - AC / DC

• Device protection class V0 IP-50, fireproof plastic

• Specifications of different models of controller devices