LA700
Technical reference for LA700 with 31 pages, 32 tables, searchable navigation and precise source-page references.
- Chapters
- 1
- Pages
- 31
- Language
- English
- Format

Complete web edition
The complete manual in one reading flow
Pages follow the exact source order. Searchable text is also available for every page.
Complete document
Pages 1 to 31
Source page
Page 1
LA700
AC Drive for High Performance Elevator
Applications
Technical Data Sheet
Type: CIPR-LA70Cxxxxxxxx-9600
400 V Class, Three-Phase Input: 4.0 to 160 kW
Source page
Page 2
Copyright © 2025 YASKAWA Europe GmbH All rights reserved. No part of this publication may be reproduced, stored in a retrieval system, or transmitted, in any form or by any means, mechanical, electronic, photocopying, recording, or otherwise, without the prior written permission of Yaskawa. No patent liability is assumed with respect to the use of the information contained herein. Moreover, because Yaskawa is constantly striving to improve its high-quality products, the information contained in this manual is subject to change without notice. Every precaution has been taken in the preparation of this manual. Yaskawa assumes no responsibility for errors or omissions. Neither is any liability assumed for damages resulting from the use of the information contained in this publication.
Source page
Page 3
Contents
Introduction .............................................................................................................................................. 1
Drive Selection......................................................................................................................................... 1 How to Read Model Numbers .............................................................................................................. 2 List of Models ....................................................................................................................................... 3
General specification ............................................................................................................................... 4 Power Ratings ......................................................................................................................................... 6
Three-phase 400 V Units ..................................................................................................................... 6 Drive Watt Loss ....................................................................................................................................... 7 Three-phase 400 V Units ..................................................................................................................... 7
Deratings ................................................................................................................................................. 8 Carrier Frequency Derating ................................................................................................................. 8
Ambient Temperature Derating............................................................................................................ 9 Altitude Derating .................................................................................................................................. 9 Built-in EMC Filters / Leakage Current .................................................................................................. 10
Electrical Connections ........................................................................................................................... 11 Connection Diagram .......................................................................................................................... 11
Dimensions and Weight ......................................................................................................................... 12 400V class: 4kW to 30kW .................................................................................................................. 12 400V class: 37kW to 160kW .............................................................................................................. 13
Accessories & Power Options ............................................................................................................... 14 Network Communications Option Cards ............................................................................................ 14
Motor Speed Feedback Option Card ................................................................................................. 14 Speed Reference Card ...................................................................................................................... 14 LED/LCD Keypads ............................................................................................................................. 15
PC Connection Cable (USB) .............................................................................................................. 16 Keypad Door Mounting Kits ............................................................................................................... 16
Cable Shield Clamp Kit ...................................................................................................................... 17 AC Line Reactors / Power Coordinating Reactor .............................................................................. 18 D1000: Regenerative Converter (AFE) .............................................................................................. 19
R1000: The intelligent regenerative braking unit ............................................................................... 21 Dynamic braking with Braking Resistors ........................................................................................... 23
LA700 online info ................................................................................................................................... 26 Certification/Declaration ..................................................................................................................... 26 LA700 Info Page ................................................................................................................................ 26
Software Tools ....................................................................................................................................... 27 Software Tools ................................................................................................................................... 27
LA700 | YASKAWA Europe GmbH |
Source page
Page 4
Introduction
Introduction
The LA700 offers best in class and most reliable drive performance on the market.
The LA700 is the first choice for new installation, machine room less lifts, but also for modernization. Experience the proven YASKAWA reliability combined with a new level of ride comfort.
The LA700 comes with a sophisticated vector control algorithm and lift dedicated control functions which assure a bump-free start also without load sensor, smooth speed transition and precise landing. The performance features are well-suited for both Induction and Permanent Magnet motors with the latest control functions.
Yaskawa Europe is happy to serve innovative technology paired with hardware designed for 10 years of maintenance free operation.
Drive Selection
LA700 drives must be selected according to power supply voltage, motor rated current, load profile of the application, and ambient condition of the environment they are operated in. Yaskawa Europe GmbH recommends sizing the drive capacity to match the load factor during operation (load factor at constant speed) does not exceed 80% of the 50% ED current.
LA700 drives are designed to be wall mounted upright and in clean environmental condition. In case of special mounting methods, high ambient temperature (>50 °C), high altitude (> 1000 m), use of high carrier frequency, an output current derating must be considered when selecting the drive.
Examine the drive for damage. Immediately contact the shipping company if the drive is damaged. The Yaskawa warranty does not cover damage from shipping.
Verify the drive model number to make sure that you received the correct model. Verify the model number in the “MODEL” section of the drive nameplate to make sure that you received the correct model.
If you received a product different than you ordered or a product with a defect, contact Yaskawa or your nearest sales representative.
LA700 | YASKAWA Europe GmbH | 1
Source page
Page 5
How to Read Model Numbers
The following diagram and table describe how to read model number of the crane drive.
CIPR - LA70 C 4 005 C B A A - HAAAAA - 9600
1 2 3 4 5 6 7 8 9 10
No. Description 1 Drive Series
Product Series 2 • LA70: LA700 Region code 3 • C: Europe Voltage class 4 • 4: 400V 3-phase
Rated output current (50% ED) 5 Note: Refer to the list of models EMC filter 6 • A: no built-in EMC filter • C: Built-in EMC filter category C2
Enclosure design 7 • B: IP20
Environmental specification 8 • A: Standard
9 Design revision order
VAG Number 10 • 9600: Local European Product
2 YASKAWA Europe GmbH | LA700
| Column | No. | Column | Column | Description | Column |
|---|---|---|---|---|---|
| 1 | Drive Series | ||||
| 2 | Product Series • LA70: LA700 | ||||
| 3 | Region code • C: Europe | ||||
| 4 | Voltage class • 4: 400V 3-phase | ||||
| 5 | Rated output current (50% ED) Note: Refer to the list of models | ||||
| 6 | EMC filter • A: no built-in EMC filter • C: Built-in EMC filter category C2 | ||||
| 7 | Enclosure design • B: IP20 | ||||
| 8 | Environmental specification • A: Standard | ||||
| 9 | Design revision order | ||||
| 10 | VAG Number • 9600: Local European Product |
Source page
Page 6
Drive Selection
List of Models
Model 50% ED Continuos CIPR- Power Model Code SAP # Current Rated Current LA70C... 4012 4 kW 11,5 A 8,1 A CIPR-LA70C4012CBAA-HAAAAA-9600 10115850 4019 5,5 kW 18,5 A 13 A CIPR-LA70C4019CBAA-HAAAAA-9600 10115852
4023 7,5 kW 22,5 A 15,8 A CIPR-LA70C4023CBAA-HAAAAA-9600 10115854
4030 11 kW 30 A 21 A CIPR-LA70C4030CBAA-HAAAAA-9600 10115856
4039 15 kW 38,8 A 27,1 A CIPR-LA70C4039CBAA-HAAAAA-9600 10115858
4049 18,5 kW 48,8 A 34,1 A CIPR-LA70C4049CBAA-HAAAAA-9600 10116078
4056 22 kW 56,3 A 39,4 A CIPR-LA70C4056CBAA-HAAAAA-9600 10116080
4075 30 kW 75 A 52,5 A CIPR-LA70C4075ABAA-HAAAAA-9600 10116081
4094 37 kW 93,8 A 65,6 A CIPR-LA70C4094ABAA-HAAAAA-9600 10116082
4114 45 kW 113,8 A 79,6 A CIPR-LA70C4114ABAA-HAAAAA-9600 10116083
4140 55 kW 140 A 98 A CIPR-LA70C4140ABAA-HAAAAA-9600 10116084
4188 75 kW 187,5 A 131,3 A CIPR-LA70C4188ABAA-HAAAAA-9600 10116085
4225 90 kW 225 A 157,5 A CIPR-LA70C4225ABAA-HAAAAA-9600 10116086
4270 110 kW 270 A 189 A CIPR-LA70C4270ABAA-HAAAAA-9600 10116087
4325 132 kW 325 A 227,5 A CIPR-LA70C4325ABAA-HAAAAA-9600 10116088
4380 160 kW 380 A 266 A CIPR-LA70C4380ABAA-HAAAAA-9600 10116089
LA700 | YASKAWA Europe GmbH | 3
| Model CIPR- LA70C... | Power | 50% ED Current | Continuos Rated Current | Model Code | SAP # |
|---|---|---|---|---|---|
| 4012 | 4 kW | 11,5 A | 8,1 A | CIPR-LA70C4012CBAA-HAAAAA-9600 | 10115850 |
| 4019 | 5,5 kW | 18,5 A | 13 A | CIPR-LA70C4019CBAA-HAAAAA-9600 | 10115852 |
| 4023 | 7,5 kW | 22,5 A | 15,8 A | CIPR-LA70C4023CBAA-HAAAAA-9600 | 10115854 |
| 4030 | 11 kW | 30 A | 21 A | CIPR-LA70C4030CBAA-HAAAAA-9600 | 10115856 |
| 4039 | 15 kW | 38,8 A | 27,1 A | CIPR-LA70C4039CBAA-HAAAAA-9600 | 10115858 |
| 4049 | 18,5 kW | 48,8 A | 34,1 A | CIPR-LA70C4049CBAA-HAAAAA-9600 | 10116078 |
| 4056 | 22 kW | 56,3 A | 39,4 A | CIPR-LA70C4056CBAA-HAAAAA-9600 | 10116080 |
| 4075 | 30 kW | 75 A | 52,5 A | CIPR-LA70C4075ABAA-HAAAAA-9600 | 10116081 |
| 4094 | 37 kW | 93,8 A | 65,6 A | CIPR-LA70C4094ABAA-HAAAAA-9600 | 10116082 |
| 4114 | 45 kW | 113,8 A | 79,6 A | CIPR-LA70C4114ABAA-HAAAAA-9600 | 10116083 |
| 4140 | 55 kW | 140 A | 98 A | CIPR-LA70C4140ABAA-HAAAAA-9600 | 10116084 |
| 4188 | 75 kW | 187,5 A | 131,3 A | CIPR-LA70C4188ABAA-HAAAAA-9600 | 10116085 |
| 4225 | 90 kW | 225 A | 157,5 A | CIPR-LA70C4225ABAA-HAAAAA-9600 | 10116086 |
| 4270 | 110 kW | 270 A | 189 A | CIPR-LA70C4270ABAA-HAAAAA-9600 | 10116087 |
| 4325 | 132 kW | 325 A | 227,5 A | CIPR-LA70C4325ABAA-HAAAAA-9600 | 10116088 |
| 4380 | 160 kW | 380 A | 266 A | CIPR-LA70C4380ABAA-HAAAAA-9600 | 10116089 |
| Model |
|---|
| CIPR- |
| LA70C... |
| 50% ED |
|---|
| Current |
| Continuos |
|---|
| Rated Current |
Source page
Page 7
General specification
ltem Specification • V/f Control • Open Loop Vector Control Method • Closed Loop Vector • PM Closed Loop Vector Frequency Control Range 0.01 Hz to 200 Hz Frequency Accuracy Digital inputs: ±0.01% of the maximum output speed (-10 °C to +40 °C (14 °F to 104 °F)) (Temperature Fluctuation) Analog inputs: ±0.1% of the maximum output speed (25 °C ±10 °C (77 °F ±18 °F)) Frequency Setting Resolution Digital inputs: 0.01 Hz Analog inputs: 1/2048 of the maximum output speed (11-bit signed) Output Frequency Resolution 0.001 Hz Frequency Setting Signal Main speed reference: -10 Vdc to +10 Vdc (20 kΩ), 0 Vdc to 10 Vdc (20 kΩ), 4 mA to 20 mA (250 Ω), 0 mA to 20 mA (250 Ω) Starting Torque • V/f: 150%/3 Hz • OLV: 200%/0.3 Hz • CLV: 200%/0 min-1 (rpm) • CLV/PM: 200%/0 min-1 (rpm) Speed Control Range • V/f Control (V/f): 1:40 • Open Loop Vector Control (OLV): 1:200 • Closed Loop Vector Control (CLV): 1:1500 • Closed Loop Vector Control for PM (CLV/PM): 1:1500 Zero Speed Control Possible in these control methods: • CLV • CLV/PM Torque Limits Parameter settings allow separate limits in four quadrants in Open Loop Vector Control (OLV), Closed Loop Vector Control (CLV), and Closed Loop Vector Control for PM (CLV/PM). Accel & Decel Time 0.0 sec to 6000.0 sec Approximately 20% Approximately 125% with a dynamic braking option • Short-time average deceleration torque Motor output 0.4/0.75 kW: over 100% Motor output 1.5 kW: over 50% Motor output 2.2 kW and larger: over 20% Braking Torque • Continuous regenerative torque: Approximately 20%. Dynamic braking option allows for approximately 125%, 10% ED, 10 s Note: • Models 2022 to 2144 and 4012 to 4188 have a braking transistor. • Motor characteristics change the continuous regenerative torque and short-time average deceleration torque for motors 2.2 kW and larger. V/f Characteristics User-set V/f pattern. Main Control Functions Droop Control, Feed Forward Control, Position Lock at Start and Stop/Anti-Rollback Function, Overtorque/Undertorque Detection, Torque Limit, 8 Step Speed (max.), Accel/Decel Switch, 5 Zone Jerk Settings, Auto-Tuning (Rotational and Stationary Motor/Encoder Offset Tuning), Dwell Function, Cooling Fan ON/OFF Switch, Slip Compensation, Torque Compensation, DC Injection Braking at Start and Stop, Energy Saving Control, MEMOBUS/Modbus Communication (RS-485 max, 115.2 kbps), Automatic Fault Reset, Removable Terminal Block with Parameter Backup Function, Online Tuning, High Frequency Injection, Short Floor, Rescue Operation (Light Load Direction Search Function), Inspection Operation, Brake Sequence, Brake Torque Check Function, Speed related parameters with elevator units display, etc. Motor Protection Electronic thermal overload protection Overload Protection Drive stops when the output current is more than 171% of the continuous rated output current for 10 seconds. The permitted frequency of overload is one time each 10 minutes. Note: If output speed < 6 Hz, the drive can trigger the overload protection function when the output current is in the overload tolerance range. Overvoltage Protection 200 V class: Stops when the DC bus voltage is more than approximately 410 V 400 V class: Stops when the DC bus voltage is more than approximately 820 V Undervoltage Protection 200 V class: Stops when the DC bus voltage decreases to less than approximately 190 V 400 V class: Stops when the DC bus voltage decreases to less than approximately 380 V 4 YASKAWA Europe GmbH | LA700
Source page
Page 8
General specification
ltem Specification Heatsink Overheat Protection The drive stops when the thermistor detects an IGBT temperature more than approximately 1 00°C (212°F). The trip temperature level is different for different drive models. Braking Resistor Overheat Overheat detection for braking resistor (optional ERF-type, 3% ED) Protection Stall Prevention Stall prevention is available during acceleration, deceleration, and during run. Ground Fault Protection Electronic circuit protection Note: This protection detects any ground faults during run. The drive will not provide protection when: • There is a low-resistance ground fault for the motor cable or terminal block • Energizing the drive when there is a ground fault present. DC Bus Charge LED Charge LED illuminates when DC bus voltage is above 50 V. Area of Use Indoors Power Supply Overvoltage Category III IP20/UL Open Type: -10°C to +50 °C (14 °F to 122 °F) • When you install the drive in an enclosure, use a cooling fan or air conditioner to keep the Ambient Temperature internal air temperature in the permitted range. • Do not let the drive freeze. Humidity 95% RH or less Do not let condensation form on the drive. Storage Temperature -20 °C to +70 °C (-4 °F to +158 °F) (short-term temperature during transportation) Pollution degree 2 or less Install the drive in an area without: • Oil mist, corrosive or flammable gas, or dust • Metal powder, oil, water, or other unwanted materials • Radioactive materials or flammable materials, including wood Surrounding Area • Harmful gas or fluids • Salt • Direct sunlight Keep wood or other flammable materials away from the drive. 1000 m (3281 ft.) maximum Note: Derate the output current by 1% for each 100 m (328 ft.) to install the drive in altitudes between 1000 m to 4000 m (3281 ft. to 13123 ft.). Altitude It is not necessary to derate the rated voltage in these conditions: • Installing the drive at 2000 m (6562 ft.) or lower • Installing the drive between 2000 m to 4000 m (6562 ft. to 13123 ft.) and grounding the neutral point on the power supply. Contact Yaskawa or your nearest sales representative when not grounding the neutral point. Vibration • 10 Hz to 20 Hz: 1 G (9.8 m/s2, 32.15 ft/s2) • 20 Hz to 55 Hz: 2022 to 2225, 4012 to 4188: 0.6 G (5.9 m/s2, 19.36 ft/s2) 2269 to 2519, 4225 to 4380: 0.2 G (2.0 m/s2, 6.56 ft/s2) Installation Orientation Install the drive vertically for sufficient cooling airflow. Harmonized Standard • UL61800-5-1 • EN61800-3 • IEC/EN61800-5-1 • Two Safe Disable inputs and one EDM output according to ISO/EN13849-1 Cat.III PLe, IEC/EN61508 SIL3 Protection Design IP20/UL Open Type
LA700 | YASKAWA Europe GmbH | 5
Source page
Page 9
Power Ratings
Three-phase 400 V Units
Model CIPR-LA70C... 4012 4019 4023 4030 4039 4049 4056 4075 Maximum Applicable Motor kW 4 5,5 7,5 11 15 18,5 22 30 Capacity Cont. 8,1 13 15,8 21 27,1 34,1 39,4 52,5 50% Rated Output Current 11,5 18,5 22,5 30 38,8 48,8 56,3 75 ED 3 sec 16.7 27 37 49 62.6 78.8 97.4 120.6 Default Carrier Frequency kHz 8 10 10 10 8 8 8 8
DC Reactor External Option Built-in
Braking Transistor Built-in
Three phase 380V to 480V Maximum Output Voltage Note: The maximum output voltage is proportional to the input voltage Category C2 EMC filter built-in EMC Filter External IEC61800-3 AC Power: Three phase 380V to 480V at 50/60Hz , DC Power: 513V to 679V Power Supply Allowable Voltage Fluctation: -15% to +10%, Allowable Frequency Fluctation: ±5% Input Power kVA 9,3 13 17 24 33 40 34 46
Model CIPR-LA70C... 4094 4114 4140 4188 4225 4270 4325 4380
Maximum Applicable Motor kW 37 45 55 75 90 110 132 160 Capacity Cont. 65,6 79,6 98 131,3 157,5 189 227,5 266 50% Rated Output Current 93,8 113,8 140 187,5 225 270 325 380 ED 3 sec Default Carrier Frequency kHz 5 5 5 5 5 5 5 5
DC Reactor Built-in
Braking Transistor Built-in External Three phase 380V to 480V Maximum Output Voltage Note: The maximum output voltage is proportional to the input voltage EMC Filter External AC Power: Three phase 380V to 480V at 50/60Hz , DC Power: 513V to 679V Power Supply Allowable Voltage Fluctation: -15% to +10%, Allowable Frequency Fluctation: ±5% Input Power kVA 57 69 84 113 135 165 198 239
6 YASKAWA Europe GmbH | LA700
| Model CIPR-LA70C... | Column | 4012 | 4019 | 4023 | 4030 | 4039 | 4049 | 4056 | 4075 |
|---|---|---|---|---|---|---|---|---|---|
| 4 | 5,5 | 7,5 | 11 | 15 | 18,5 | 22 | |||
| 8,1 | 13 | 15,8 | 21 | 27,1 | 34,1 | 39,4 | |||
| 11,5 | 18,5 | 22,5 | 30 | 38,8 | 48,8 | 56,3 | |||
| 16.7 | 27 | 37 | 49 | 62.6 | 78.8 | 97.4 | |||
| 8 | 10 | 10 | 10 | 8 | 8 | 8 | |||
| External Option |
| Model CIPR-LA70C... | Column | 4094 | 4114 | 4140 | 4188 | 4225 | 4270 | 4325 | 4380 |
|---|---|---|---|---|---|---|---|---|---|
| 37 | 45 | 55 | 75 | 90 | 110 | 132 | |||
| 65,6 | 79,6 | 98 | 131,3 | 157,5 | 189 | 227,5 | |||
| 93,8 | 113,8 | 140 | 187,5 | 225 | 270 | 325 | |||
| 5 | 5 | 5 | 5 | 5 | 5 | 5 |
Source page
Page 10
Drive Watt Loss
Drive Watt Loss
Three-phase 400 V Units
LA700 Drive Heat Losses Model CIPR- LA70C... Carrier Inside Outside Total Loss Power Current Frequency (W) (W) (W) (kHz) 4012 4 kW 11,5 A 8 36 70 106 4019 5,5 kW 18,5 A 10 48 99 147 4023 7,5 kW 22,5 A 10 58 126 184
4030 11 kW 30 A 10 79 169 248
4039 15 kW 38,8 A 8 95 231 326
4049 18,5 kW 48,8 A 8 124 298 422
4056 22 kW 56,3 A 8 145 358 503
4075 30 kW 75 A 5 202 548 750
4094 37 kW 93,8 A 5 209 565 774
4114 45 kW 113,8 A 5 251 683 934
4140 55 kW 140 A 5 291 851 1142
4188 75 kW 187,5 A 5 408 1079 1487
4225 90 kW 225 A 5 388 1225 1613
4270 110 kW 270 A 5 483 1300 1783 4325 132 kW 325 A 5 586 1760 2346
4380 160 kW 380 A 5 696 2010 2706
LA700 | YASKAWA Europe GmbH | 7
| Model CIPR- LA70C... | Column | Column | LA700 Drive Heat Losses | Column | Column | Column |
|---|---|---|---|---|---|---|
| Power | Current | Carrier Frequency (kHz) | Inside (W) | Outside (W) | Total Loss (W) | |
| 4 kW 11,5 A | ||||||
| 5,5 kW 18,5 A | ||||||
| 7,5 kW 22,5 A | ||||||
| 11 kW 30 A | ||||||
| 15 kW 38,8 A | ||||||
| 18,5 kW 48,8 A | ||||||
| 22 kW 56,3 A | ||||||
| 30 kW 75 A | ||||||
| 37 kW 93,8 A | ||||||
| 45 kW 113,8 A | ||||||
| 55 kW 140 A | ||||||
| 75 kW 187,5 A | ||||||
| 90 kW 225 A | ||||||
| 110 kW 270 A | ||||||
| 132 kW 325 A | ||||||
| 160 kW 380 A |
| Model CIPR- |
|---|
| LA70C... |
| Carrier |
|---|
| Frequency |
| (kHz) |
| Inside |
|---|
| (W) |
| Outside |
|---|
| (W) |
| Total Loss |
|---|
| (W) |
Source page
Page 11
Deratings
Carrier Frequency Derating
The rated current of LA700 drives might need to be reduced depending on the selected carrier frequency.
LA700 Continuose Rated Output Current in Ampere Model CIPR- LA70C... Power Current 2 kHz 5 kHz 8 kHz 10 kHz 12.5 kHz 15 kHz 4012 4 kW 8,1 A 8,1 8,1 8,1 7,1 5,9 4,7
4019 5,5 kW 13 A 13 13 13 13 11,2 9,5
4023 7,5 kW 15,8 A 15,8 15,8 15,8 15,8 14,1 12,4
4030 11 kW 21 A 21 21 21 21 18,6 16,2 4039 15 kW 27,1 A 27,1 27,1 27,1 24 20,1 16,3
4049 18,5 kW 34,1 A 34,1 34,1 34,1 30,8 27,1 23,4
4056 22 kW 39,4 A 39,4 39,4 39,4 35,5 31,2 26,8
4075 30 kW 52,5 A 52,5 52,5 52,5 46,5 39 31,5
4094 37 kW 65,6 A 65,6 65,6 54,3 46,8 37,5 28,1
4114 45 kW 79,6 A 79,6 79,6 69,1 62,1 53,3 44,6
4140 55 kW 98 A 98 98 80,4 68,6
4188 75 kW 131,3 A 131,3 131,3 107,6 91,9
4225 90 kW 157,5 A 157,5 157,5 129,2 110,3
4270 110 kW 189 A 189 189 155 132,3
4325 132 kW 227,5 A 227,5 227,5 186,6 159,3
4380 160 kW 266 A 266 266 218,1 186,2
8 YASKAWA Europe GmbH | LA700
| Model CIPR- LA70C... | Column | Column | LA700 Continuose Rated Output Current in Ampere | Column | Column | Column | Column | Column |
|---|---|---|---|---|---|---|---|---|
| Power | Current | 2 kHz | 5 kHz | 8 kHz | 10 kHz | 12.5 kHz | 15 kHz | |
| 4 kW 8,1 A | ||||||||
| 5,5 kW 13 A | ||||||||
| 7,5 kW 15,8 A | ||||||||
| 11 kW 21 A | ||||||||
| 15 kW 27,1 A | ||||||||
| 18,5 kW 34,1 A | ||||||||
| 22 kW 39,4 A | ||||||||
| 30 kW 52,5 A | ||||||||
| 37 kW 65,6 A | ||||||||
| 45 kW 79,6 A | ||||||||
| 55 kW 98 A | ||||||||
| 75 kW 131,3 A | ||||||||
| 90 kW 157,5 A | ||||||||
| 110 kW 189 A | ||||||||
| 132 kW 227,5 A | ||||||||
| 160 kW 266 A |
| Model CIPR- |
|---|
| LA70C... |
Source page
Page 12
Deratings
Ambient Temperature Derating
Depending on the mounting condition, enclosure type and ambient temperature derating factors need to be applied on the rated output current of LA700 drives. The derating curves shown below
are valid for all frames of LA700.
Altitude Derating
LA700 drives can be operated at altitudes up to 1000 m without derating. Between 1000 and 4000 m altitude above sea level a derating of 1 % per 100 m must be applied to the rated output current.
Additionally, a derating must be applied to the rated voltage if the drive is installed over 2000 m above sea level with the neutral point of the power supply ungrounded.
LA700 | YASKAWA Europe GmbH | 9
Source page
Page 13
Built-in EMC Filters / Leakage Current
LA700 Drives are without an embedded EMC filter. Internal EMC filters are designed to be used in TN grids. The filters shall be disabled when using the drive in an ungrounded system or a system that is not grounded symmetrically.
CIPR- Current Power IEC61800-3 Category Cable Length *1 LA70C4□□□ (50% ED) 4012 4 kW 11,5 A C2 10 m 4019 5,5 kW 18,5 A C2 10 m 4023 7,5 kW 22,5 A C2 10 m 4030 11 kW 30,0 A C2 10 m 4039 15 kW 38,8 A C2 10 m
4049 18,5 kW 48,8 A C2 10 m 4056 22 kW 56,3 A C2 10 m
Note: *1 Shielded Motor Cable
10 YASKAWA Europe GmbH | LA700
| CIPR- |
|---|
| LA70C4□□□ |
| Current |
|---|
| (50% ED) |
Source page
Page 14
Electrical Connections
Electrical Connections
Connection Diagram
*For more details check LA700 Technical Manual chapter 3.5 Control Circuit Wiring
LA700 | YASKAWA Europe GmbH | 11
Source page
Page 15
Dimensions and Weight
400V class: 4kW to 30kW
L M A o 7 d 0 e C l □ C □ IP □ R □ - Power E D x M im t o e e u ri n n o s t r i i n o a g n n s d W H D D1 D2 W1 W2 W5 H1 H2 H4 t1 t2 d W ( e k i g g ) h t
4012 4 kW 140 260 211 138 73 102 102 248 6 2 5 M5 3,9 4019 5,5 kW Figure 1 140 260 211 138 73 102 102 248 6 2 5 M5 4,1
4023 7,5 kW 140 260 211 138 73 102 102 248 6 2 5 M5 4,1
4030 11 kW 180 300 202 134 68 140 140 284 8 2 2 M5 5,5 Figure 2 4039 15 kW 180 300 202 134 68 140 140 284 8 2 2 M5 5,5
4049 18,5 kW 220 350 227 140 87 192 192 335 8 2 2 M6 8,5 Figure 3 4056 22 kW 220 350 227 140 87 192 192 335 8 2 2 M6 13
4075 30 kW Figure 4 240 400 280 166 114 195 186 12 375 18 18 2 2 M6 15
Figure 1 Figure 2
Figure 3 Figure 4
12 YASKAWA Europe GmbH | LA700
| Model CIPR- LA70C□□□□ | Power | Exterior and Mounting Dimensions | W | H | D | D1 | D2 | W1 | W2 | W5 | H1 | H2 | H4 | t1 | t2 | d | Weight (kg) |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 4012 | 4 kW | Figure 1 | 140 | 260 | 211 | 138 | 73 | 102 | 102 | 248 | 6 | 2 | 5 | M5 | 3,9 | ||
| 4019 | 5,5 kW | 140 | 260 | 211 | 138 | 73 | 102 | 102 | 248 | 6 | 2 | 5 | M5 | 4,1 | |||
| 4023 | 7,5 kW | 140 | 260 | 211 | 138 | 73 | 102 | 102 | 248 | 6 | 2 | 5 | M5 | 4,1 | |||
| 4030 | 11 kW | Figure 2 | 180 | 300 | 202 | 134 | 68 | 140 | 140 | 284 | 8 | 2 | 2 | M5 | 5,5 | ||
| 4039 | 15 kW | 180 | 300 | 202 | 134 | 68 | 140 | 140 | 284 | 8 | 2 | 2 | M5 | 5,5 | |||
| 4049 | 18,5 kW | Figure 3 | 220 | 350 | 227 | 140 | 87 | 192 | 192 | 335 | 8 | 2 | 2 | M6 | 8,5 | ||
| 4056 | 22 kW | 220 | 350 | 227 | 140 | 87 | 192 | 192 | 335 | 8 | 2 | 2 | M6 | 13 | |||
| 4075 | 30 kW | Figure 4 | 240 | 400 | 280 | 166 | 114 | 195 | 186 | 12 | 375 | 18 | 18 | 2 | 2 | M6 | 15 |
| Exterior and |
|---|
| Mounting |
Source page
Page 16
Dimensions and Weight
400V class: 37kW to 160kW
L M A o 7 d 0 e C l □ C □ IP □ R □ - Power E D x M im t o e e r u i n n o s t r i i n o a g n n s d W H D D1 D2 W1 W2 W5 H1 H2 H3 H4 t1 t2 d W ( e k i g g ) h t
4094 37 kW 225 450 280 166 114 170 165 12 424 16 29 21 2 2 M6 20 Figure 5 4114 45 kW 225 450 280 166 114 170 165 12 424 16 29 21 2 2 M6 25
4140 55 kW 264 543 335 186 149 190 182 12 516 18 29 21 2 2 M8 37 Figure 6 4188 75 kW 264 543 335 186 149 190 182 12 516 18 29 21 2 2 M8 38
4225 90 kW 312 700 420 260 160 218 218 18 659 28 44 29 5 5 M10 61 4270 110 kW Figure 7 312 700 420 260 160 218 218 18 659 28 44 29 5 5 M10 63
4325 132 kW 312 700 420 260 160 218 218 18 659 28 44 29 5 5 M10 66
4380 160 kW Figure 8 440 800 472 254 218 370 370 20 757 28 44 30 5 5 M12 107
Figure 5 Figure 6
Figure 7 Figure 8
LA700 | YASKAWA Europe GmbH | 13
| Model CIPR- LA70C□□□□ | Power | Exterior and Mounting Dimensions | W | H | D | D1 | D2 | W1 | W2 | W5 | H1 | H2 | H3 | H4 | t1 | t2 | d | Weight (kg) |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 4094 | 37 kW | Figure 5 | 225 | 450 | 280 | 166 | 114 | 170 | 165 | 12 | 424 | 16 | 29 | 21 | 2 | 2 | M6 | 20 |
| 4114 | 45 kW | 225 | 450 | 280 | 166 | 114 | 170 | 165 | 12 | 424 | 16 | 29 | 21 | 2 | 2 | M6 | 25 | |
| 4140 | 55 kW | Figure 6 | 264 | 543 | 335 | 186 | 149 | 190 | 182 | 12 | 516 | 18 | 29 | 21 | 2 | 2 | M8 | 37 |
| 4188 | 75 kW | 264 | 543 | 335 | 186 | 149 | 190 | 182 | 12 | 516 | 18 | 29 | 21 | 2 | 2 | M8 | 38 | |
| 4225 | 90 kW | Figure 7 | 312 | 700 | 420 | 260 | 160 | 218 | 218 | 18 | 659 | 28 | 44 | 29 | 5 | 5 | M10 | 61 |
| 4270 | 110 kW | 312 | 700 | 420 | 260 | 160 | 218 | 218 | 18 | 659 | 28 | 44 | 29 | 5 | 5 | M10 | 63 | |
| 4325 | 132 kW | 312 | 700 | 420 | 260 | 160 | 218 | 218 | 18 | 659 | 28 | 44 | 29 | 5 | 5 | M10 | 66 | |
| 4380 | 160 kW | Figure 8 | 440 | 800 | 472 | 254 | 218 | 370 | 370 | 20 | 757 | 28 | 44 | 30 | 5 | 5 | M12 | 107 |
| Exterior and |
|---|
| Mounting |
Source page
Page 17
Accessories & Power Options
Network Communications Option Cards
The communication option cards listed below can be mounted on CR700 drive. They are shipped lose together with the required installation material. Network Type Model Codes SAP # CANopen SI-S3 100-046-870 CANlift* SI-L3 *will be available in 2H’2025
Motor Speed Feedback Option Card
The Motor Speed Feedback Option Card allows the user to connect a driver encoder (PG) for motor speed feedback to the drive to increase the control accuracy and performance in V/f w/PG, CLV, AOLV, and CLV/PM control methods.
This PG encoder signal allows the drive to compensate for subtle variations in the load while providing the drive with the necessary data to control the output frequency and maintain an accurate constant speed.
For motor speed feedback option card details and compatible encoder types check the technical manual.
Encoder Type Model Codes SAP # Open Collector (HTL) PG-B3 10062639 Line Driver (TTL/RS422) PG-X3 100-046-872 ERN1387 PG-E3 500-033-406 EnDat, HIPERFACE PG-F3 100-067-860 BiSS PG-F3-B 10114797
Speed Reference Card
Enables high-precision and high-resolution analog/digital speed reference setting.
Input Signal Model Codes SAP # Analog Input (3 inputs) AI-A3 100-046-873 (-10 to +10Vdc or 4 to 20mA) Digital Input DI-A3 100-046-875 (BCD Code)
14 YASKAWA Europe GmbH | LA700
Source page
Page 18
Accessories & Power Options
LED/LCD Keypads
LCD Keypad (standard) Model Code: JVOP-KPLCA04AEA SAP # 10105769
This optional LCD keypad greatly improves the operability of the drive. The high-res screen can display graphics and multi-language full text. Additional functions are: Start-up Wizard, copy function (4 sets of parameters), backup, data logging, real-time clock.
LCD Bluetooth Keypad Model Code: JVOP-KPLCC04ABA SAP # 10099085
This optional LCD keypad provides the ability to connect to the drive using Bluetooth. It is designed to be able to operate like the LCD keypad if keypad navigation is required.
This keypad is used in conjunction with DriveWizard Mobile to connect to the drive via Bluetooth. You can download DriveWizard Mobile to your mobile device through the Apple AppStore or Google Play.
LED Full Size Keypad Model Code: JVOP-KPLEA04AAA SAP # 10010185
This optional LED keypad provides a larger LED display (5 digit, 7 segments) and larger navigation buttons for more comfort during drive operation.
Note: The LED keypad does not support the Remote Display functionality of CANopen Lift and DCP. Further, it has some restrictions regarding the Travel Direction Change Counter functionality and the Setup Wizard.
LA700 | YASKAWA Europe GmbH | 15
Source page
Page 19
Extension Cables Extension cables for keypads are offered in two lengths.
Model Description SAP # Number WV001-YEG Keypad Remote Mount Cable - 1 Meter 10007058
WV003-YEG Keypad Remote Mount Cable - 3 Meter 10012366
PC Connection Cable (USB) Model Number Description SAP # JZSP-CVS06-02-E USB-mini connection cable for PC 2.5m 300-100-888
Keypad Door Mounting Kits
Door Mounting Kits for LCD Keypads (with or without Bluetooth) The LCD keypads can be mounted to a panel front door using one of the mounting kits below.
Type of Mounting Brackets have tapped holes for use with brackets have untapped holes for use with screws panel studs Model Number 900-192-933-001 900-192-933-002 SAP # 10090514 10090515 Appearance
16 YASKAWA Europe GmbH | LA700
Source page
Page 20
Accessories & Power Options
Cable Shield Clamp Kit A cable shield kit can be mounted at the bottom of the drive, in order to easy cable shield connection and provide a strain relief at the same time
Important: • Cable shield and UL Type 1 kits cannot be installed simultaneously.
Model Shield CIPR- Power W H D D1 D2 D3 W1 H0 H3 Clamp Kit LA70C (Model No.) 4□□□ 012 4 kW 140 339 211 73 96 158 137 260 79 100-206-983 019 5,5 kW 140 339 211 73 96 158 137 260 79 100-206-983 023 7,5 kW 140 339 211 73 96 158 137 260 79 100-206-983 030 11 kW 180 439 202 68 93 148 175 298 141 100-206-984 039 15 kW 180 439 202 68 93 148 175 298 141 100-206-984
LA700 | YASKAWA Europe GmbH | 17
| Column | Model | Column | Power | W | H | D | D1 | D2 | D3 | W1 | H0 | H3 | Shield Clamp Kit (Model No.) |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| CIPR- | |||||||||||||
| LA70C | |||||||||||||
| 4□□□ |
| Shield |
|---|
| Clamp Kit |
| (Model No.) |
Source page
Page 21
AC Line Reactors / Power Coordinating Reactor
Input reactors can be applied to reduce harmonic distortion on the AC input line. Reactors are offered with 4% uk. IP20 covers are separately available.
Model SAP # SAP# CIPR- Power Current IP00 IP20 cover (IP00) (IP20 cover) LA70C... 4012 4 kW 11,5 A B 1103136 IP20-BOX32 10008858 10062614 4019 5,5 kW 18,5 A B 1103138 IP20-BOX35 10000040 10062617 4023 7,5 kW 22,5 A B 1103139 IP20-BOX36 10000041 10062618
4030 11 kW 30 A B 1103140 IP20-BOX37 10000042 10062619
4039 15 kW 38,8 A B 1103140 IP20-BOX37 10000042 10062619
4049 18,5 kW 48,8 A B 1103141 IP20-BOX39 10008862 10062621
4056 22 kW 56,3 A B 1103142 IP20-BOX39 10008863 10062621
4075 30 kW 75 A B 1103142 IP20-BOX39 10008863 10062621
4094 37 kW 93,8 A B 0910013 IP20-BOX42 10008857 10062624 4114 45 kW 113,8 A B 0910013 IP20-BOX42 10008857 10062624
4140 55 kW 140 A B 1411053 IP20-BOX46 10008876 10062628
18 YASKAWA Europe GmbH | LA700
| Model |
|---|
| CIPR- |
| LA70C... |
| SAP # |
|---|
| (IP00) |
| SAP# |
|---|
| (IP20 cover) |
Source page
Page 22
Accessories & Power Options
D1000: Regenerative Converter (AFE)
The D1000 regenerative converter unit complements the Yaskawa product range with a low harmonics Active Frontend Solution. Suitable for standard and regenerative applications with individual drives or systems of inverter drives, the D1000 feeds excess braking energy back into the power grid instead of dissipating it as heat and keep the harmonic migration below 5% under full load.
The D1000 KIT is a pre-configured package that include D1000 regenerative converter unit, EMC filter, input reactor(s) and harmonic filter module.
D1000 KIT (with THD filter module in IP00 protection) Power D1000 KIT Model Code SAP #
5 kW D1KIT40005AAAAB 10009715
10 kW D1KIT40010AAAAB 10009718 20 kW D1KIT40020AAAAB 10009722
30 kW D1KIT40030AAAAB 10009726
40 kW D1KIT40040AAAAB 10009730
60 kW D1KIT40060AAAAB 10009734 100 kW D1KIT40100AAAAB 10009736
130 kW D1KIT40130AAAAB 10009738
185 kW D1KIT40185AAAAB 10009740
D1000 KIT (with THD filter module in IP20 protection) Power D1000 KIT Model Code SAP #
5 kW D1KIT40005AABAB 10009716
10 kW D1KIT40010AABAB 10009719
20 kW D1KIT40020AABAB 10009723
30 kW D1KIT40030AABAB 10009727 40 kW D1KIT40040AABAB 10009731
For more detail such as dimensions or weight check the D1000 catalog or visit the D1000 (D1000 Regenerative Converter) or LA700 (LA700 Premium Lift Drive) web information.
LA700 | YASKAWA Europe GmbH | 19
Source page
Page 23
Schematic diagram
LA700
LA700
LA700
D1000 KIT components (example with IP20 THD filter cover)
D1000 Regenerative THD filter Converter Unit
EMC filter THD filter cover (IP20)
20 YASKAWA Europe GmbH | LA700
Source page
Page 24
Accessories & Power Options
R1000: The intelligent regenerative braking unit
The R1000 regenerative braking unit is a smart and efficient alternative to dynamic braking for single or multi-axis drive installations with a high amount of regenerative motor operation. Instead of wasting the braking energy as heat, the R1000 feeds excessive braking energy back to the grid.
The R1000 KIT is a pre-configured package that include R1000 regenerative converter unit and current suppression reactor.
To comply with EN12015 customer must add the Power Coordinating Reactor (see page 18). For details refer also to R1000 catalog.
Model Code Model Code Power SAP # SAP # (R1000 KIT with IP20 reactor) (R1000 KIT with IP00 reactor) 3,5 kW R1KIT40003AABAA 10011484 R1KIT40003AAAAA 10011483
5 kW R1KIT40005AABAA 10011486 R1KIT40005AAAAA 10011485 7 kW R1KIT40007AABAA 10011488 R1KIT40007AAAAA 10011487
10 kW R1KIT40010AABAA 10011490 R1KIT40010AAAAA 10011489
14 kW R1KIT40014AABAA 10011492 R1KIT40014AAAAA 10011491
17 kW R1KIT40017AABAA 10011494 R1KIT40017AAAAA 10011493
20 kW R1KIT40020AABAA 10011496 R1KIT40020AAAAA 10011495 28 kW R1KIT40028AABAA 10011498 R1KIT40028AAAAA 10011497
35 kW R1KIT40035AABAA 10011500 R1KIT40035AAAAA 10011499
43 kW R1KIT40043AABAA 10011502 R1KIT40043AAAAA 10011501
53 kW R1KIT40053AABAA 10011504 R1KIT40053AAAAA 10011503
73 kW R1KIT40073AABAA 10011506 R1KIT40073AAAAA 10011505 105 kW R1KIT40105AABAA 10011508 R1KIT40105AAAAA 10011507
150 kW R1KIT40150AABAA 10011510 R1KIT40150AAAAA 10011509
Note: Each system that incorporates an R1000 unit must include the Power Coordinating Reactor, Current Suppression Reactor and EMC Filter. The Current Suppression Reactor must only withstand the regenerative current and is therefore included in the R1000 kit. However, the Power Coordinating Reactor (AC Input Reactor) and EMC Filter must also withstand the motoring current going into de system. Since the input current can be higher than the regenerative current depending on the application, these components must be ordered separately. Fuses in the R1000 branch must be installed by the customer according to Yaskawa recommendations. For more detail such as dimensions or weight check the R1000 catalog or visit the R1000 (R1000 Regenerative Unit) or LA700 (LA700 Premium Lift Drive) web information.
LA700 | YASKAWA Europe GmbH | 21
| Power | Model Code (R1000 KIT with IP20 reactor) | SAP # | Model Code (R1000 KIT with IP00 reactor) | SAP # |
|---|---|---|---|---|
| R1KIT40003AABAA 10011484 | ||||
| R1KIT40005AABAA 10011486 | ||||
| R1KIT40007AABAA 10011488 | ||||
| R1KIT40010AABAA 10011490 | ||||
| R1KIT40014AABAA 10011492 | ||||
| R1KIT40017AABAA 10011494 | ||||
| R1KIT40020AABAA 10011496 | ||||
| R1KIT40028AABAA 10011498 | ||||
| R1KIT40035AABAA 10011500 | ||||
| R1KIT40043AABAA 10011502 | ||||
| R1KIT40053AABAA 10011504 | ||||
| R1KIT40073AABAA 10011506 | ||||
| R1KIT40105AABAA 10011508 | ||||
| R1KIT40150AABAA 10011510 |
| Model Code |
|---|
| (R1000 KIT with IP20 reactor) |
| Model Code |
|---|
| (R1000 KIT with IP00 reactor) |
Source page
Page 25
Schematic diagram
LA700
R1000 KIT components (example with IP20 reactor cover)
R1000 Regenerative Current suppression reactor Converter Unit
Power Coordinating Reactor Reactor cover (IP20)
22 YASKAWA Europe GmbH | LA700
Source page
Page 26
Accessories & Power Options
Dynamic braking with Braking Resistors
When lowering a load with a crane the motor works in regenerative mode for the whole lowering process. Reason for this is an additional energy feedback (kinetic energy of the machine) to the inverter while deceleration. The motor must produce a braking torque which causes voltage increase on the DC bus. This causes a rise of the DC bus voltage. If the feedback energy is too high, the inverter may trip with an overvoltage fault (OV). In this case a braking resistor or a combination of a braking unit and a braking resistor must be used to dissipate the energy as heat.
CR700 drives have embedded braking transistors up to drive capacity of 75kW. Resistors selected from the table below can be directly connected to terminals B1 and B2. When connecting other resistors, the resistance must be higher than the minimum value listed below. See more details on next page
Schematic diagram
LA700
Dynamic braking item examples
CDBR-4045D Braking Resistor Series RH
LA700 | YASKAWA Europe GmbH | 23
Source page
Page 27
Braking resistor (40% ED) without Thermosensor
Braking Unit Braking Resistor*1 Model LA C 7 I 0 P C R □ - □□ C B h ra o k p i p n e g r Qty. Material No. R 40 e % sis E to D r Qty. Res M is in to . r*2 Co D n ia n g e r c a t m io n SAP # [Ω] 4012 RH-1000W120 1 55 A 10004349
4019 RH-1560W040 1 32 A 10004350 4023 RH-2700W025 1 32 A 10004351
4030 RH-3700W040 1 20 A 10004352 4039 RH-4800W022 1 20 A 10004353
4049 RH-6000W022 1 19,2 A 10004356 Built-in Braking Transistor 4056 RH-7500W023 1 19,2 A 10004357 4075
4094 40114
4140 4188 On request, contact you r sales representative
4225 CDBR 4270 CDBR On request, contact your 4325 CDBR repre s s a e le n s ta tive 4380 CDBR Note: 40% ED: 120 s cycle time (t) and 48 s switch on time (ton) Connection Diagram A
Connection Diagram A
24 YASKAWA Europe GmbH | LA700
| Model CIPR- LA70C□□□ | Braking Unit | Column | Column | Braking Resistor*1 | Column | Column | Column | Column | Column | Column |
|---|---|---|---|---|---|---|---|---|---|---|
| Braking Chopper | Qty. | Material No. | Resistor 40% ED | Qty. | Min. | Connection Diagram | SAP # | |||
| Resistor*2 | ||||||||||
| [Ω] | ||||||||||
| Built-in Braking Transistor | ||||||||||
| CDBR On request, CDBR contact your sales CDBR representative CDBR |
| Model |
|---|
| CIPR- |
| LA70C□□□ |
Source page
Page 28
Accessories & Power Options
*1: Refers to a motor coasting to stop with a constant torque load. Constant output and regenerative braking will reduce the duty factor. Applications with a relatively large amount of regenerative power may require more braking power than is possible with the standard braking unit and braking resistor unit only. If the braking torque exceeds the value shown in the table, the capacity of the braking resistor unit must be increased.
*2: This value is the min. resistor value which can be connected to the drive. Lower value will result in damage of the LA700 and/or braking unit. The braking unit should have a resistance higher than the minimum connectable resistance value and be able to generate enough braking torque to stop the motor. For more information on the braking resistor check the technical data sheet of the resistor or contact your nearest Yaskawa sales representative. *3: When using multiple braking resistor units, connect them in parallel.
General Note:
- Be sure to protect braking resistors by thermal overload relay
Dimensions: CDBR braking unit
Braking Max. discharge current (A) Rated discharge current (A) Watt Loss SAP # Unit 10% ED (10 sec. max) continuous (W) 4045D 60 18 36 100-091-723 4090D 100 30 51 100-091-525 4220D 250 80 152 100-091-526
CDBR-4045D CDBR-4090D
General Note: - Be sure to protect braking resistors by thermal overload relay - When using more than one braking unit connected in parallel, set one of the braking units as the master, and set the others as slaves - Connect CDBR fault relay output to multi-function digital input S (External Fault). Connect the CDBR transistor short-circuit detection output to disconnect main input power to the drive
CDBR-4220D
LA700 | YASKAWA Europe GmbH | 25
| Column | Braking | Column | Column | Max. discharge current (A) | Column | Column | Rated discharge current (A) | Column | Column | Watt Loss | Column | SAP # |
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Unit | 10% ED (10 sec. max) | continuous | (W) |
Source page
Page 29
LA700 online info
Certification/Declaration
The latest version of LA700 product certification/declaration can be downloaded from Yaskawa website.
Use the link Download Center to access Yaskawa document download. Enter the search name LA700 and change the Document Type to Certification for declaration and certification files.
LA700 Info Page
LA700 Online Info
26 YASKAWA Europe GmbH | LA700
Source page
Page 30
Software Tools
Software Tools
Software Tools
Tool Description System Connection DriveWizard 10 PC Tool for parameter Windows USB-mini management/backup/diagnostics DriveWizard Mobile app for parameter Android • Bluetooth Mobile management/backup/diagnostics • USB-mini with USB on-the- go adapter iPhone • Bluetooth
LA700 | YASKAWA Europe GmbH | 27
Source page
Page 31
LA700
ELEVATE YOUR LIFESTYLE
Document: LA700 Data Sheet, v1.1 Published: 20.03.2025
Technical data
Highlighted specifications
| Specification | Value | Page |
|---|---|---|
| Model CIPR- LA70C... | Power | 50% ED Current | Continuos Rated Current | Model Code | SAP # | 6 |
| Model CIPR-LA70C... | 4012 | 4019 | 4023 | 4030 | 4039 | 4049 | 4056 | 4075 | 9 |
| Model CIPR-LA70C... | 4094 | 4114 | 4140 | 4188 | 4225 | 4270 | 4325 | 4380 | 9 |
| Model CIPR- LA70C... | LA700 Drive Heat Losses | 10 |
| Model CIPR- LA70C... | LA700 Continuose Rated Output Current in Ampere | 11 |
| Model CIPR- LA70C□□□□ | Power | Exterior and Mounting Dimensions | W | H | D | D1 | D2 | W1 | W2 | W5 | H1 | H2 | H4 | t1 | t2 | d | Weight (kg) | 15 |
| Model CIPR- LA70C□□□□ | Power | Exterior and Mounting Dimensions | W | H | D | D1 | D2 | W1 | W2 | W5 | H1 | H2 | H3 | H4 | t1 | t2 | d | Weight (kg) | 16 |
| Power | Model Code (R1000 KIT with IP20 reactor) | SAP # | Model Code (R1000 KIT with IP00 reactor) | SAP # | 24 |
| Model CIPR- LA70C□□□ | Braking Unit | Braking Resistor*1 | 27 |
Related products
Products covered by this document
- CIPR-LA70C4012ABA-9600Product page
- CIPR-LA70C4012CBA-9600Product page
- CIPR-LA70C4019ABA-9600Product page
- CIPR-LA70C4019CBA-9600Product page
- CIPR-LA70C4023ABA-9600Product page
- CIPR-LA70C4023CBA-9600Product page
- CIPR-LA70C4030ABA-9600Product page
- CIPR-LA70C4030CBA-9600Product page
- CIPR-LA70C4039ABA-9600Product page
- CIPR-LA70C4039CBA-9600Product page