LA700
The Lift Drive
yaskawa.eu
Source page
Page 2
Best value
for lift
LA700 lift drives are the solution to technical requirements of today’s elevators. This lift drive controls induction and permanent magnet
motors. It is the first choice for new installation, machine room less lifts, but also for modernization. Experience the
proven Yaskawa reliability combined with a new level of ride comfort.
Source page
Page 3
Drawing upon more than 100 years of experience in
driving motors, Yaskawa develops products which perfectly combine technical superiority with easy operation.
Our number one priority is to always keep the customer’s perspective in mind. We offer the highest market benchmark in quality and product reliability.
We can now deliver ideal solutions for various tasks related to the operation of elevators and escalators, including brake sequences that have evolved from the
technologies we have developed to date.
Key features
• Super-smooth ride comfort • Quieter operation thanks to new frequency adjustment function • Advanced light load search for evacuation (smaller UPS) • SIL3 STO (Zero contactor solution) • BiSS support • Integrated Class C2 EMC filter • Coated PCBs according to 3C2, 3S2 by default • Embedded braking chopper (up to 75 kW) • Fast installation and easy setup thanks to our intuitive start-up wizard • Smart MRL replacement • Motor tuning in stand-still condition without removing ropes • For gearless and geared lifts • Up to 4 m/s • Certified Brake Monitor Function for UCM:EN 81-1:1998+A3:2009 9.11.3 and EN 81-20:2014 5.6.7.3
Advanced functions
• Direct to floor • Monitors for motor temperature, peak current and lifetime • Advanced short floor management • Elevator setup wizard • Support for 13 languages • Torque compensation (load cell optional) • DCP3*, DCP4* and CAN Lift*
Source page
Page 4
The power
to lift!
10 Y Des E ign A ed f R or S o fr f e m e a o i p n e te ra n t a io n n ce
Source page
Page 5
Key features and benefits
Designed to drive both induction and permanent magnet motors, LA700 drives are
becoming the preferred choice for various applications, including new installations, machine-room-less lifts and modernisation projects. By choosing an LA700 drive, you can experience our proven reliability with a higher standard of ride comfort, ensuring a
modern and efficient solution for today’s lift systems.
Super-smooth ride Anti-rollback Safety Input
comfort feature + torque (SIL 3) compensation as an Ride profiles with individual jerk With its built-in dual-channel STO setting for each speed change and option (Safe Torque Off) circuit and EDM different selectable acceleration/ (Electronic Device Monitor) signal, deceleration ramps allow fine tuning the LA700 provides the right tools for a smooth and shockless ride. For improved ride comfort, the for easy integration of emergency starting torque when releasing the stop functions into the lift, even • Five individual jerk settings for each brake is set during commissioning. when higher levels of safety are speed change. required. This allows lift motors to be • Up 4 to different selectable • Improved Anti-Back function for operated without motor contactors in acceleration/deceleration ramps. smooth starting accordance with EN81-20. • Dedicated and easy to adjust lift • Torque compensation function also brake sequence. available with load cell. • Silent operation • Saves panel space • Three independent Speed Loop settings for fine tuning. (ASR) • Less parts, less probability of (Start/Constant/Stop) Short floor function failure means less call outs for maintenance • Allows fine tuning for a smooth and comfortable ride. The Short Floor function controls that the movement distance when Lifetime monitoring decelerating from the highest Rescue & evacuation frequency or nominal speed to & predictive the leveling speed. In all cases function (positioning accuracy) is the same. maintenance This means, that the elevator covers different distances, if the leveling When the power fails and people speed command is set at different Monitor the life of your drive and need to be rescued, we have the new speeds. minimize unplanned downtime. Advanced Light Load function. The LA700 will automatically evacuate • Short floor operation is used when • Number of run commands in the direction of regeneration. This the fast speed is not reached • Drive and fan running time function allows the use of smaller between floors. • Capacitor, IGBT SoftCharger relay, UPS. UPS or DC battery backup can • It optimizes the leveling speed/ be used. distance of the lift and reduces the • Cooling fan life travelling time. • Drive temperature • Drive, motor overload • Peak current 5
Source page
Page 6
Makes your life
easier
The LA700 drive comes with value-adding functions and smart features which offer benefits throughout the entire life cycle of an installation. No matter whether in drive selection, through design, during installation, start
up or troubleshooting, the LA700 makes life easy.
Temperature controlled fans
Cooling fans run only when needed. Audible noise and contamination is minimized while service intervals can be prolonged.
Tactile keypad
The bright LED display and tactile buttons make menu navigation easy and intuitive. The removable keypad can serve as a parameter backup or copy unit.
Robust design
The LA700 can be operated at altitudes of up to 4000 m and in high-temperature environments of up to 60°C. Coated PCBs protect the drive against dust and mist.
Embedded braking chopper Built-in EMC filter
Direct connection of a braking resistor reduces the number of parts, Built in class C2 filters allow for compliance with EN12015 required space and simplifies the installation. without the need for external EMC filters.
Source page
Page 7
Common menus
Menus and parameters are arranged and named as with any other Yaskawa drive, thus reducing training expenses.
USB port
Easily connect to your PC or mobile device for programming, monitoring or troubleshooting the LA500.
Minimal service requirements
Designed for over 2 million full-load starts and 10 years of maintenance-free operation.
Screwless control terminals
Easily create long-lasting, reliable connections without the need for periodical re-tightening.
24 VDC power for sensors
Internal power supply delivers an extra 150 mA for use with external sensors, thus eliminating the need for a separate power supply.
24 VDC power input for controller Easily accessible main circuit terminals
Simplify your wiring and keep the drive's command interface Connect main circuit and motor cables in shortest time without operational, even during standby or power outages. removing any covers.
Source page
Page 8
Usability
first
Source page
Page 9
Copy function Reduce set-up time
Multiple sets of parameters can be stored and easily • Start-up wizard transferred (copied) to additional drives. • Favorite parameter/monitor function • Copy function integrated into the keypad • Parameter set is backward compatible with previous generation drive products Hi-resolution display • Fast navigation • Parameter description Contrast control offers clear and readable full-text descriptions. Drive parameter management • Storage of up to 4 drive Automatic backup function parameter sets • Data logging with real time stamp e.g. for fault analysis, load profile analysis etc. (up to 32 GB on a Micro SD card) Saves the current parameter settings after a period of user • Fault logging with real time stamp for better analysis inactivity. After an incident, settings can be retrieved from the keypad in a couple of seconds. • Multiple parameter storage • Automatic parameter back-up Easy to use Advanced keypad navigation Faster scrolling and function keys provide more responsive • LCD keypad with Bluetooth® option navigation and shortcuts that reduce programming time. • Display contrast control • Real-time clock with time stamp • Tactile feel buttons • Remote mounting of keypad using standard RJ45 extension cable Real-time clock Real-time clock for time stamp of fault information (battery Elevator Start-up wizard compartment in back).
The start-up wizard reduces setup time to just a few minutes. It guides you through basic setup using simple questions that do not require any knowledge of drive parameters, saving valuable time. Micro SD storage Micro SD for data logging storage.
Optional LCD keypad with
Bluetooth®
Wireless communication capability between the mobile device and drive.
Source page
Page 10
Relaxing in daily use
and installation
Enjoy a smooth and comfortable ride of your lift. The excellent motor control of the the
LA700 and the integrated brake control sequence guarantee for soft changes in speed and accurate landing.
Ride profiles with individual jerk setting for each speed change • Adjustable speed profiles with individual jerk settings and different selectable acceleration/deceleration ramps • Accurate leveling independent allow fine tuning for a smooth and shockless ride. of load The accurate leveling control of LA700 makes floor and • Short floor management cabin ground even under any load condition, thus avoiding • Easy to tune brake sequence for smooth ride and best dangerous traps. landing The flexible brake control sequence optimizes the start and • Evacuation in light direction for smallest possible UPS/ stop for soft movement and accurate landing. battery
10
Source page
Page 11
Easy Start-up Sustainable
The integrated EMC filter and braking chopper make With its innovative design the LA700 paves the way to installation faster, reduce wiring, save space and time. sustainable lift system. The LA700 is designed with durability in mind. It can stand more than 2 million full load starts while Intuitive menus with lift terminology (terms and units on components are selected to provide up to 10 years operation LC display) simplify the setup procedure. free of maintenance. Operate the lift without motor contactors - just make use The drive’s cooling fans are temperature controlled and only of the Safe Torque Off function (STO, SIL3) of the LA700. run when really required. This avoids pollution by twirling dust Avoiding additional contactors also reduce the space required, inside the panel, improves reliability, and minimizes the need wiring effort and eliminates switching noise. for regular maintenance. • Integrated EMC filter with class C2 for EN12015 and LA700 is not only reliable, it also helps to make your lift green. EN12016 compliance The very low stand-by power consumption of only approx. • Integrated braking chopper 10 W saves energy and helps to achieve Class 1 rating in terms • Integrated SIL3 STO function for operation without motor of efficiency for your elevator (according to ISO 25745-2; max contactors 50 W). • Flexible control sequence to work with almost any controller • Long lasting design • Setup in lift terminology and units • Maintenance free • Automatic motor data tuning in stand still condition without • Energy saving by super low stand-by consumption removing ropes 11
Source page
Page 12
Integrated
functional safety
12
Source page
Page 13
With the built-in dual channel STO (safe torque off) circuit and EDM signal (electronic device monitor) the LA700 provides the right tools for an easy integration of emergency stop functions into machines, even when higher levels of safety are required.
Risk reduction
made easy
• STO with SIL3/PLe according to IEC 61800-5-2/IEC 61508/ISO 13849 • EDM monitor • Lower number of parts reduces installation effort while increasing reliability • TÜV Süd certified
Conventional Drive
Embedded
functional safety
The built-in STO replaces mechanical emergency relays. The electronic sequencing improves reliability and cost compared to mechanical components.
13
Source page
Page 14
Quick & easy setup
Self-guiding navigation menus and start-up wizards make the programming and set-up faster and easier than ever. With DriveWizard Mobile the LA700 can easily
be managed and controlled from your smartphone or tablet.
14
Source page
Page 15
DriveWizard Mobile
DriveWizard mobile is the ultimate • Intuitive parameter editing with help • Troubleshooting support with fault setup tool for LA700 drives. From and search functions analysis and countermeasures simple parameter editing to the • Create favorite parameter lists • Export to DriveWizard PC tool Setup Wizard with an 8 channel fully • 8-channel oscilloscope with • Worry-free data recovery: featured oscilloscope, it provides comprehensive trigger functions Parameter back-up/retrieval all the tools needed for setup, and data analysis anytime via Yaskawa cloud service monitoring, and process optimization. • Parameter backup/verify for registered drives • Setup Wizard for quick setup • Usable offline in areas without without knowledge of menus and mobile reception parameters • Programming without power Mobile device connectivity Mobile device connectivity is achieved through using the built-in USB port or wireless communication with the Bluetooth® LCD keypad option. Search for YASKAWA
on
1. Bluetooth keypad optional 2. Supports Android and iOS
15
Source page
Page 16
Relaxing in daily use
and installation
Enjoy a smooth and comfortable ride of your lift. The excellent motor control of the the LA700 and the integrated brake control sequence guarantee for soft changes in speed
and accurate landing.
Model Merit Braking D1000 R1000 resistor Use for regenerative applications v b b Energy saving by power regeneration - b b Improve power factor - b - Suppress input current harmonics - b - DC voltage boost - b - Multiple drives - b -
Best performance
Minimum operation cost
Small carbon footprint R1000 regenerative unit
The R1000 regenerative unit with • Suitable for 4-quadrant operation block circuit is an environmentally without braking resistors friendly, sustainable alternative for • Eliminating braking resistors saves braking resistors. space and simplifies installation Compared to conventional solutions, • Less cooling required for the the R1000 regenerative unit saves control cabinet because no heat is space and reduces maintenance generated by resistors work. The energy fed back into the • Recovered energy can be made grid also contributes to cost savings available to other consumers in and at the same time protects the the plant, thus reducing the total environment! energy consumption of buildings or factories • Quick amortization of initial costs • Proven Yaskawa quality
16
| Merit | Model | Column | Column |
|---|---|---|---|
| Braking resistor | D1000 | R1000 | |
| Use for regenerative applications | v | b | b |
| Energy saving by power regeneration | - | b | b |
| Improve power factor | - | b | - |
| Suppress input current harmonics | - | b | - |
| DC voltage boost | - | b | - |
| Multiple drives | - | b | - |
Source page
Page 17
D1000 regenerative converter unit
The D1000 regenerative unit saves • Constant sinusoidal input and both power and space. It is suitable feedback for individual regenerative AC drives • No distortion of the input voltage as well as for systems of AC drives, • Stable intermediate circuit voltage servo axes or robots. • DC gain It feeds excess braking energy • Very low harmonics back into the power grid instead of converting it to heat. The DC voltage • Common DC bus for several AC amplification function increases the drives reliability of the system even when variable or fluctuating input voltages are present. Clean grid with D1000
88% Input current Sinusoidal input current 5% Standard AC drive with D1000 Current distortion Current distortion 0.75 0.98
Power factor Power factor
Less energy needed from grid Energy direction D1000 package
Regenerative energy
LA700 LA700 LA700 LA700 LA700 LA700
17
Source page
Page 18
L A700
Catalog code
LA70 C 4 012 C B A A 9600
1 2 3 4 5 6 7 8 9
1 Drive series 5 EMC filter option LA70 LA700 series A No EMC filter C C: C2 built-in *1 2 Region code C Europe 6 Enclosure B IP20 3 Drive rating 2 200 V, 3-phase 7 Environmental spec 4 400 V, 3-phase A Standard
4 50% ED rated output current 8 Hardware revision ... See Ratings table A Standard
9 Customized version
9600 Standard
18
| 1 | Drive series |
|---|---|
| LA70 | LA700 series |
| 5 | EMC filter option |
|---|---|
| A | No EMC filter |
| C | C: C2 built-in *1 |
| 2 | Region code |
|---|---|
| C | Europe |
| 6 | Enclosure |
|---|---|
| B | IP20 |
| 3 | Drive rating |
|---|---|
| 2 | 200 V, 3-phase |
| 4 | 400 V, 3-phase |
| 7 | Environmental spec |
|---|---|
| A | Standard |
| 4 | 50% ED rated output current |
|---|---|
| ... | See Ratings table |
| 8 | Hardware revision |
|---|---|
| A | Standard |
| 9 | Customized version |
|---|---|
| 9600 | Standard |
Source page
Page 19
Ratings - 200 V models
Max Appl. Motor Continuous Output 50% ED Rated Catalog Code Power (HD) Current Output Current Dimensions [mm] Weight [kg] LA70C [kW] [A] [A] W H D 2022 3.7 17.5 21.9 3.8 2031 5.5 25 31.3 140 260 211 4.2 2041 7.5 33 41.3 2059 11 47 58.8 180 300 202 6 2075 15 60 75 8.5 220 350 227 2094 18.5 75 93.8 9.5 2110 22 88 110 240 400 280 18 2144 30 115 143.8 255 450 280 22 2181 37 145 181.3 34 264 543 335 2225 45 180 225 35 2269 55 215 268.8 59 312 700 420 2354 75 283 353.8 62 2432 90 346 432 101 440 800 472 2519 110 415 518.8 107 Ratings - 400 V models Max Appl. Motor Continuous Output 50% ED Rated Catalog Code Power (HD) Current Output Current Dimensions [mm] Weight [kg] LA70C [kW] [A] [A] W H D 4012 4.0 8.1 11.5 3.9 4019 5.5 13 18.5 140 260 211 4.1 4023 7.5 15.8 22.5 4030 11 21 30 5.5 180 300 202 4039 15 27.1 38.8 6.0 4049 18.5 34.1 48.8 8.5 220 350 227 4056 22 39.4 56.3 13 4075 30 52.5 75 240 400 280 15 4094 37 65.6 93.8 20 255 450 280 4114 45 79.6 113.8 25 4140 55 98 140 37 264 543 335 4188 75 131.3 187.5 38 4225 90 157.5 225 61 4270 110 189 270 312 700 420 63 4325 132 227.5 325 66 4380 160 266 380 440 800 472 107
19
| Catalog Code LA70C | Max Appl. Motor Power (HD) | Continuous Output Current | 50% ED Rated Output Current | Dimensions [mm] | Column | Column | Weight [kg] |
|---|---|---|---|---|---|---|---|
| [kW] | [A] | [A] | W | H | D | ||
| 2022 | 3.7 | 17.5 | 21.9 | 140 | 260 | 211 | 3.8 |
| 2031 | 5.5 | 25 | 31.3 | 4.2 | |||
| 2041 | 7.5 | 33 | 41.3 | ||||
| 2059 | 11 | 47 | 58.8 | 180 | 300 | 202 | 6 |
| 2075 | 15 | 60 | 75 | 220 | 350 | 227 | 8.5 |
| 2094 | 18.5 | 75 | 93.8 | 9.5 | |||
| 2110 | 22 | 88 | 110 | 240 | 400 | 280 | 18 |
| 2144 | 30 | 115 | 143.8 | 255 | 450 | 280 | 22 |
| 2181 | 37 | 145 | 181.3 | 264 | 543 | 335 | 34 |
| 2225 | 45 | 180 | 225 | 35 | |||
| 2269 | 55 | 215 | 268.8 | 312 | 700 | 420 | 59 |
| 2354 | 75 | 283 | 353.8 | 62 | |||
| 2432 | 90 | 346 | 432 | 440 | 800 | 472 | 101 |
| 2519 | 110 | 415 | 518.8 | 107 |
| Catalog Code LA70C | Max Appl. Motor Power (HD) | Continuous Output Current | 50% ED Rated Output Current | Dimensions [mm] | Column | Column | Weight [kg] |
|---|---|---|---|---|---|---|---|
| [kW] | [A] | [A] | W | H | D | ||
| 4012 | 4.0 | 8.1 | 11.5 | 140 | 260 | 211 | 3.9 |
| 4019 | 5.5 | 13 | 18.5 | 4.1 | |||
| 4023 | 7.5 | 15.8 | 22.5 | ||||
| 4030 | 11 | 21 | 30 | 180 | 300 | 202 | 5.5 |
| 4039 | 15 | 27.1 | 38.8 | 6.0 | |||
| 4049 | 18.5 | 34.1 | 48.8 | 220 | 350 | 227 | 8.5 |
| 4056 | 22 | 39.4 | 56.3 | 13 | |||
| 4075 | 30 | 52.5 | 75 | 240 | 400 | 280 | 15 |
| 4094 | 37 | 65.6 | 93.8 | 255 | 450 | 280 | 20 |
| 4114 | 45 | 79.6 | 113.8 | 25 | |||
| 4140 | 55 | 98 | 140 | 264 | 543 | 335 | 37 |
| 4188 | 75 | 131.3 | 187.5 | 38 | |||
| 4225 | 90 | 157.5 | 225 | 312 | 700 | 420 | 61 |
| 4270 | 110 | 189 | 270 | 63 | |||
| 4325 | 132 | 227.5 | 325 | 66 | |||
| 4380 | 160 | 266 | 380 | 440 | 800 | 472 | 107 |
Source page
Page 20
Connection diagram
noitallatsnIlacirtcelE 3.2 Standard Connection Diagram
Figure 3.1 Standard Drive Connection Diagram 20
YASKAWA SIEPC7106172DB LA700 Series Technical Manual 57
Source page
Page 21
Specification
Item Specification Motor types Induction Motor (IM), Permanent magnet motor (PM) Control methods V/f Control, Open Loop Vector, Closed Loop Vector, PM Closed Loop Vector Motor parameter tuning Automatic, rotating/static
Anti-Rollback Function, Overtorque/Undertorque Detection, Torque Limit, 5 Zone Jerk Settings, Auto-Tuning (Rotational and Stationary Motor/Encoder Offset Tuning), Cooling Fan ON/OFF Switch, Energy Saving Control, MEMOBUS/Modbus Communication (RS-485 max, 115.2 kbps), Main control functions Automatic Fault Reset, Online Tuning, High Frequency Injection, Short Floor, Rescue Operation (Light Load Direction Search Function), Inspection Operation, Brake Sequence, Brake Torque Check Function, etc. Motor protection, Momentary overcurrent protection, Overload protection, Overvoltage protection, Protective functions Undervoltage protection, Heatsink overheat protection, Braking resistor overheat protection, Stall prevention, Ground fault protection, etc. Monitoring of main components (fans, IGBTs, capacitors, charging circuit) with maintenance Self-monitoring alarm notification Communication options SI-S3 CANopen Ambient temperature IP20: -10 to +50 °C Storage temperature -20 to +70 °C Humidity 95 % RH or less (non-condensing) Altitude Up to 1000 m without derating, up to 4000 m with derating 10 to 20 Hz: 9.8 m/s2 Vibration/Shock 20 to 55 Hz: 5.9 m/s2 Protection design IP20 standard Environmental conditions IEC 60721-3-3, Class 3C2 (chemical gases), Class 3S2 (solid particles) Standards CE, UKCA EN 61800-5-1, EN 61800-3, EN ISO 13849-1:2015 (PL e (Cat.3)), EN 62061 (SILCL3), EN 61800-5- Functional safety 2 (SIL3), EN IEC 63000, IEC 61800-9-2, IEC/CE 60664, UL 61800-5-1, IEC/EN 61000-6-7, IEC/EN 61508 Overload capacity 210% of continuous rated output current for 3 s 200 V Class: 200 to 240 VAC, -15 to +10 % Rated voltage 400 V Class: 380 to 480 VAC, -15 to +10 % 200 V Class: 4.0 to 110 kW Capacity range (HD) 400 V Class: 4.0 to 160 kW Output frequency 0 to 200 Hz Carrier frequency 8 kHz/10 kHz; max. 15 kHz with derating Braking transistor Integrated up to 75 kW (200 V class), up to 160 kW (400 V class) Control inputs 10 digital, 3 analog (1×V/I, 2×V) Control outputs 4 relay, 2 photo coupler, 2 analog Programming interface Mini-USB on the front cover; digital operator with Bluetooth® (optional) High-resolution LCD operator included (bluetooth keypad optional), tactile soft buttons, copy Keypad function (removable), storage for up to 4 parameter sets Serial communication Memobus/Modbus, RS-485, up to 115 kbit/s
21
| Item | Specification | Column |
|---|---|---|
| Motor types | Induction Motor (IM), Permanent magnet motor (PM) | |
| Control methods | V/f Control, Open Loop Vector, Closed Loop Vector, PM Closed Loop Vector | |
| Motor parameter tuning | Automatic, rotating/static | |
| Main control functions | Anti-Rollback Function, Overtorque/Undertorque Detection, Torque Limit, 5 Zone Jerk Settings, Auto-Tuning (Rotational and Stationary Motor/Encoder Offset Tuning), Cooling Fan ON/OFF Switch, Energy Saving Control, MEMOBUS/Modbus Communication (RS-485 max, 115.2 kbps), Automatic Fault Reset, Online Tuning, High Frequency Injection, Short Floor, Rescue Operation (Light Load Direction Search Function), Inspection Operation, Brake Sequence, Brake Torque Check Function, etc. | |
| Protective functions | Motor protection, Momentary overcurrent protection, Overload protection, Overvoltage protection, Undervoltage protection, Heatsink overheat protection, Braking resistor overheat protection, Stall prevention, Ground fault protection, etc. | |
| Self-monitoring | Monitoring of main components (fans, IGBTs, capacitors, charging circuit) with maintenance alarm notification | |
| Communication options | SI-S3 | CANopen |
| Ambient temperature | IP20: -10 to +50 °C | |
| Storage temperature | -20 to +70 °C | |
| Humidity | 95 % RH or less (non-condensing) | |
| Altitude | Up to 1000 m without derating, up to 4000 m with derating | |
| Vibration/Shock | 10 to 20 Hz: 9.8 m/s2 | |
| 20 to 55 Hz: 5.9 m/s2 | ||
| Protection design | IP20 standard | |
| Environmental conditions | IEC 60721-3-3, Class 3C2 (chemical gases), Class 3S2 (solid particles) | |
| Standards | CE, UKCA | |
| Functional safety | EN 61800-5-1, EN 61800-3, EN ISO 13849-1:2015 (PL e (Cat.3)), EN 62061 (SILCL3), EN 61800-5- 2 (SIL3), EN IEC 63000, IEC 61800-9-2, IEC/CE 60664, UL 61800-5-1, IEC/EN 61000-6-7, IEC/EN 61508 | |
| Overload capacity | 210% of continuous rated output current for 3 s | |
| Rated voltage | 200 V Class: 200 to 240 VAC, -15 to +10 % | |
| 400 V Class: 380 to 480 VAC, -15 to +10 % | ||
| Capacity range (HD) | 200 V Class: 4.0 to 110 kW | |
| 400 V Class: 4.0 to 160 kW | ||
| Output frequency | 0 to 200 Hz | |
| Carrier frequency | 8 kHz/10 kHz; max. 15 kHz with derating | |
| Braking transistor | Integrated up to 75 kW (200 V class), up to 160 kW (400 V class) | |
| Control inputs | 10 digital, 3 analog (1×V/I, 2×V) | |
| Control outputs | 4 relay, 2 photo coupler, 2 analog | |
| Programming interface | Mini-USB on the front cover; digital operator with Bluetooth® (optional) | |
| Keypad | High-resolution LCD operator included (bluetooth keypad optional), tactile soft buttons, copy function (removable), storage for up to 4 parameter sets | |
| Serial communication | Memobus/Modbus, RS-485, up to 115 kbit/s |
Source page
Page 22
Lifting everyone to a
sustainable tomorrow
Achieving the European climate goals
To achieve European “Green Deal” Similar regulations and labels exist However, it was recognized that climate targets, the ErP (Energy- for industrial applications such as much more energy could be saved related Products) Directive was compressors, fans, pumps, etc., and by controlling the speed of electric created, which is often referred electric motors, which are estimated motors and so Regulation (EU) to as the Ecodesign Directive. It to consume half of the electrical 2019/1781 was published, which provides a framework but does energy produced in the EU, have not now regulates the efficiency of not contain product-specific been spared. the variable speed drive that work requirements, as these are so alongside the motors. diverse that they cannot possibly be covered by just one directive. Consequently, implementation regulations have been defined, based on the ErP Directive, which regulate EU climate goals by 2030 the requirements for the energy At least 55% cuts in At least 32% share for efficiency of products. greenhouse gas emissions renewable energy (from 1990 levels) At least 32.5% improvement in energy efficiency ErP Directive 2009/125/EG (EcoDesign) 1st July 2021 Regulations / 643/2009 640/2009/EG 1781/2019 Directives EN IEC/EN IEC Standard 62552:2013 60034-30-1 61800-9
Efficiency at a glance Watt loss according to IEC 61800-9-2 and efficiency class according to (EU) 2019/1781 To determine the efficiency of a VFD (Variable Frequency Drive), the loss values are measured at eight defined load points and in standby according to the IEC 61800-9-2 IE classes standard. The loss value at the load point (90, 100) (90% speed, 100% load) is compared with a defined reference IE2 Loss < Ref* 75% value. If it is below 75 % of the reference value, the device corresponds to the highest efficiency class IE2. IE1 Reference Loss CDM data IE0 Loss > Ref* 125% (complete drive module)
You can follow this QR code or visit yaskawa.eu.com/ecodesign for more information on this subject. 22
| Regulations / Directives | Column | 643/2009 | Column | 640/2009/EG | Column | 1781/2019 | Column |
|---|---|---|---|---|---|---|---|
| Standard | EN 62552:2013 | IEC/EN 60034-30-1 | IEC 61800-9 |
| Watt loss according to IEC 61800-9-2 and efficiency class according to (EU) 2019/1781 |
|---|
| IE classes IE2 Loss < Ref* 75% IE1 Reference Loss CDM data IE0 Loss > Ref* 125% (complete drive module) |
Source page
Page 23
Shaping
the future.
Sustainably.
Together.
23
Source page
Page 24
Yaskawa in Europe, Middle East, Africa AT YASKAWA Europe GmbH Linz +43 732 272 075 CZ YASKAWA Czech s.r.o. Rudná u Prahy +420 257 941 718 DE YASKAWA Europe GmbH Hattersheim am Main +49 6196 569 500 DK YASKAWA Nordic AB Horsens +46 480 417 800 ES YASKAWA Iberica S.L. Barcelona +34 93 630 34 78
FI YASKAWA Finland Oy Turku +358 40 3000 608 FR YASKAWA France S.A. Le Bignon +33 240 13 19 19 IL YASKAWA Europe Technology Ltd Rosh Ha’ayin +972 732 40 08 00 IT YASKAWA Italia SRL Milan +39 02 4969 3699 LV YASKAWA Nordic AB Riga +371 2 2467570 NL YASKAWA Benelux B.V. Eindhoven +31 40 289 55 00 PL YASKAWA Polska Sp. z o.o. Wrocław +48 71 792 86 70 SE YASKAWA Nordic AB Kalmar +46 480 417 800 TR YASKAWA Turkey Elektrik Ticaret Limited Sirketi Ümraniye-Istanbul +90 216 527 34 50 UK YASKAWA UK Ltd Washington +44 330 678 1990
YASKAWA Europe GmbH
Philipp-Reis-Str. 6 65795 Hattersheim am Main Germany
+49 6196 569-500 support@yaskawa.eu www.yaskawa.eu.com
YEU_INV_LA700 | EN | v3 09/2025
Images may contain special options. Ordered product may look different. Bluetooth® and the Bluetooth logo are registered trademarks of Bluetooth Specifications are subject to change without notice for ongoing product SIG, Inc. USA. AndroidTM is a trademark of Google Inc.iOS® is a registered modifications and improvements. © YASKAWA Europe GmbH. All rights trademark of Cisco and is used under license by Apple, Inc. reserved.
Technical data
Highlighted specifications
| Specification | Value | Page |
|---|---|---|
| Merit | Model | 16 |
| Use for regenerative applications | v | b | b | 16 |
| Energy saving by power regeneration | - | b | b | 16 |
| Improve power factor | - | b | - | 16 |
| Suppress input current harmonics | - | b | - | 16 |
| DC voltage boost | - | b | - | 16 |
| Multiple drives | - | b | - | 16 |
| LA70 | LA700 series | 18 |
| Catalog Code LA70C | Max Appl. Motor Power (HD) | Continuous Output Current | 50% ED Rated Output Current | Dimensions [mm] | Weight [kg] | 19 |
| Item | Specification | 21 |
| Motor types | Induction Motor (IM), Permanent magnet motor (PM) | 21 |
| Control methods | V/f Control, Open Loop Vector, Closed Loop Vector, PM Closed Loop Vector | 21 |
| Motor parameter tuning | Automatic, rotating/static | 21 |
| Main control functions | Anti-Rollback Function, Overtorque/Undertorque Detection, Torque Limit, 5 Zone Jerk Settings, Auto-Tuning (Rotational and Stationary Motor/Encoder Offset Tuning), Cooling Fan ON/OFF Switch, Energy Saving Control, MEMOBUS/Modbus Communication (RS-485 max, 115.2 kbps), Automatic Fault Reset, Online Tuning, High Frequency Injection, Short Floor, Rescue Operation (Light Load Direction Search Function), Inspection Operation, Brake Sequence, Brake Torque Check Function, etc. | 21 |
| Protective functions | Motor protection, Momentary overcurrent protection, Overload protection, Overvoltage protection, Undervoltage protection, Heatsink overheat protection, Braking resistor overheat protection, Stall prevention, Ground fault protection, etc. | 21 |
| Self-monitoring | Monitoring of main components (fans, IGBTs, capacitors, charging circuit) with maintenance alarm notification | 21 |
| Communication options | SI-S3 | CANopen | 21 |
| Ambient temperature | IP20: -10 to +50 °C | 21 |
| Storage temperature | -20 to +70 °C | 21 |
| Humidity | 95 % RH or less (non-condensing) | 21 |
| Altitude | Up to 1000 m without derating, up to 4000 m with derating | 21 |
| Vibration/Shock | 10 to 20 Hz: 9.8 m/s2 | 21 |
| Protection design | IP20 standard | 21 |
| Environmental conditions | IEC 60721-3-3, Class 3C2 (chemical gases), Class 3S2 (solid particles) | 21 |
| Standards | CE, UKCA | 21 |
| Functional safety | EN 61800-5-1, EN 61800-3, EN ISO 13849-1:2015 (PL e (Cat.3)), EN 62061 (SILCL3), EN 61800-5- 2 (SIL3), EN IEC 63000, IEC 61800-9-2, IEC/CE 60664, UL 61800-5-1, IEC/EN 61000-6-7, IEC/EN 61508 | 21 |
| Overload capacity | 210% of continuous rated output current for 3 s | 21 |
| Rated voltage | 200 V Class: 200 to 240 VAC, -15 to +10 % | 21 |
| Capacity range (HD) | 200 V Class: 4.0 to 110 kW | 21 |
| Output frequency | 0 to 200 Hz | 21 |
| Carrier frequency | 8 kHz/10 kHz; max. 15 kHz with derating | 21 |
| Braking transistor | Integrated up to 75 kW (200 V class), up to 160 kW (400 V class) | 21 |
Related products
Products covered by this document
- CIPR-LA70C4012ABA-9600Product page
- CIPR-LA70C4012CBA-9600Product page
- CIPR-LA70C4019ABA-9600Product page
- CIPR-LA70C4019CBA-9600Product page
- CIPR-LA70C4023ABA-9600Product page
- CIPR-LA70C4023CBA-9600Product page
- CIPR-LA70C4030ABA-9600Product page
- CIPR-LA70C4030CBA-9600Product page
- CIPR-LA70C4039ABA-9600Product page
- CIPR-LA70C4039CBA-9600Product page
Document editions