YaskawaData sheet

LA500 Data Sheet

Technical reference for LA500 Data Sheet with 25 pages, 36 tables, searchable navigation and precise source-page references.

Chapters
1
Pages
25
Language
English
Format
PDF
LA500 Data Sheet
First page of the technical document

Complete web edition

The complete manual in one reading flow

Pages follow the exact source order. Searchable text is also available for every page.

1

Complete document

Pages 1 to 25

Source page

Page 1

Open in PDF

LA500 Data Sheet

AC Compact Drive for Lift Applications

Data Sheet

Type: CIPR-LA50Cxxxxxxxx

200 V Class, Three-Phase Input: 4 to 18.5 kW 400 V Class, Three-Phase Input: 4 to 18.5 kW

Source page

Page 2

Open in PDF

Copyright © 2025 YASKAWA Europe GmbH All rights reserved. No part of this publication may be reproduced, stored in a retrieval system, or transmitted, in any form or by any means, mechanical, electronic, photocopying, recording, or otherwise, without the prior written permission of Yaskawa. No patent liability is assumed with respect to the use of the information contained herein. Moreover, because Yaskawa is constantly striving to improve its high-quality products, the information contained in this manual is subject to change without notice. Every precaution has been taken in the preparation of this manual. Yaskawa assumes no responsibility for errors or omissions. Neither is any liability assumed for damages resulting from the use of the information contained in this publication.

Source page

Page 3

Open in PDF

This page is available in the source PDF.

Source page

Page 4

Open in PDF

Contents

Introduction .............................................................................................................................................. 4

Drive Selection......................................................................................................................................... 4 Model Designation ............................................................................................................................... 5

List of Models ....................................................................................................................................... 6 General specification ............................................................................................................................... 7 Power Ratings ......................................................................................................................................... 9

Integrated EMC Filters ........................................................................................................................... 10 Watt Loss ............................................................................................................................................... 11

Deratings ............................................................................................................................................... 12 Carrier Frequency Derating ............................................................................................................... 12 Ambient Temperature Derating.......................................................................................................... 13

Altitude Derating ................................................................................................................................ 13 Electrical Connections ........................................................................................................................... 14

Connection Diagram .......................................................................................................................... 14 Dimensions ............................................................................................................................................ 15 Accessories ........................................................................................................................................... 16

Motor Speed Feedback option ........................................................................................................... 16 LED/LCD Keypads ............................................................................................................................. 17

Keypad Door Mounting Kits ............................................................................................................... 18 Heatsink External Mounting Kit .......................................................................................................... 19 Cable Shield Clamp Kit ...................................................................................................................... 20

Power Options ....................................................................................................................................... 21 AC Input Reactors .............................................................................................................................. 21

Braking Resistors ............................................................................................................................... 22 Tools and Software ................................................................................................................................ 23 Tools .................................................................................................................................................. 23

Connection Cables ............................................................................................................................. 23

Source page

Page 5

Open in PDF

Introduction

LA500 is a dedicated drive for lift applications. The key attributes are ease of use, flexibility and sustainability. Loaded with valuable features and functions the LA500 drives greatly simplifies system designs and maximize system and machine performance while reducing the effort for installation and setup to a minimum.

LA500 Online Info

Drive Selection

LA500 drives must be selected according to power supply voltage, motor rated current, load profile of the application, and ambient condition of the area they are operated in. LA500 standard drives are rated for Heavy Duty applications. In Heavy Duty the LA500 can run applications with constant torque and heavy overload of up to 165% for 30 seconds.

LA500 drives are designed to be wall mounted upright and in clean environmental condition. In case of special mounting methods (heatsink external, horizontal, etc.), high ambient temperature (>50 °C), high altitude (> 1000 m), use of high carrier frequency, and so forth, an output current derating must be considered when selecting the drive.

4 YASKAWA Europe GmbH | LA500 Data Sheet

Source page

Page 6

Open in PDF

Drive Selection

Model Designation

The following diagram and table describe how to read model number of the lift drive.

CIPR - LA50 C 4 005 E B A B

1 2 3 4 5 6 7 8 9

No. Description

1 Drive Series

Product Series 2 • LA50: LA500

Region code 3 • C: Europe

Voltage class 4 • 2: 200V 3-phase • 4: 400V 3-phase

Rated output current 5 Note: Refer to the list of models EMC filter • A: no built-in EMC filter 6 • E: Built-in EMC filter (400V: C2, 20m; 200V: C3,20m) Enclosure design 7 • B: IP20

Environmental specification 8 • A: Standard Design revision order 9 • A: Without SIL3 STO function • B: With SIL3 STO function

LA500 Data Sheet | YASKAWA Europe GmbH 5

ColumnNo.ColumnColumnDescriptionColumn
1Drive Series
2Product Series • LA50: LA500
3Region code • C: Europe
4Voltage class • 2: 200V 3-phase • 4: 400V 3-phase
5Rated output current Note: Refer to the list of models
6EMC filter • A: no built-in EMC filter • E: Built-in EMC filter (400V: C2, 20m; 200V: C3,20m)
7Enclosure design • B: IP20
8Environmental specification • A: Standard
9Design revision order • A: Without SIL3 STO function • B: With SIL3 STO function

Source page

Page 7

Open in PDF

Drive Selection

List of Models

200V Model Type Model CIPR- Power Current Model Code SAP# LA50C... LA500 2019 4 kW 17,5 A CIPR-LA50C2019EBAB 10113982

LA500 2025 5,5 kW 25 A CIPR-LA50C2025EBAB 10113983

LA500 2033 7,5 kW 33 A CIPR-LA50C2033EBAB 10113984

LA500 2047 11 kW 47 A CIPR-LA50C2047EBAB 10113985

LA500 2060 15 kW 60 A CIPR-LA50C2060EBAB 10113986 LA500 2075 18,5 kW 75 A CIPR-LA50C2075EBAB 10113987

400V Model

Type Model CIPR- Power Current Model Code SAP# LA50C... LA500 4009 4 kW 9,2 A CIPR-LA50C4009EBAB 10113988

LA500 4015 5,5 kW 14,8 A CIPR-LA50C4015EBAB 10113989

LA500 4018 7,5 kW 18 A CIPR-LA50C4018EBAB 10113990

LA500 4024 11 kW 24 A CIPR-LA50C4024EBAB 10113991 LA500 4031 15 kW 31 A CIPR-LA50C4031EBAB 10113992

LA500 4039 18,5 kW 39 A CIPR-LA50C4039EBAB 10113993

LA500 4045 22 kW 45 A CIPR-LA50C4045EBAB 10113994

6 YASKAWA Europe GmbH | LA500 Data Sheet

TypeModel CIPR- LA50C...PowerCurrentModel CodeSAP#
2019 4 kW17,5 ACIPR-LA50C2019EBAB10113982
2025 5,5 kW25 ACIPR-LA50C2025EBAB10113983
2033 7,5 kW33 ACIPR-LA50C2033EBAB10113984
2047 11 kW47 ACIPR-LA50C2047EBAB10113985
2060 15 kW60 ACIPR-LA50C2060EBAB10113986
2075 18,5 kW75 ACIPR-LA50C2075EBAB10113987
Model CIPR-
LA50C...
TypeModel CIPR- LA50C...PowerCurrentModel CodeSAP#
4009 4 kW9,2 ACIPR-LA50C4009EBAB10113988
4015 5,5 kW14,8 ACIPR-LA50C4015EBAB10113989
4018 7,5 kW18 ACIPR-LA50C4018EBAB10113990
4024 11 kW24 ACIPR-LA50C4024EBAB10113991
4031 15 kW31 ACIPR-LA50C4031EBAB10113992
4039 18,5 kW39 ACIPR-LA50C4039EBAB10113993
4045 22 kW45 ACIPR-LA50C4045EBAB10113994
Model CIPR-
LA50C...

Source page

Page 8

Open in PDF

General specification

General specification

Item Description Product Name LA500 Power Range 3-phase 200~240 V: 4 to 18.5 kW 3-phase 380~400 V: 4 to 18.5 kW Rated Input Frequency 50 Hz Allowable Voltage Fluctuation -15 to +10% Allowable Frequency Fluctuation ±5% DC Supply 200 V class: 270 to 340 Vdc 400 V class: 513 to 679 Vdc Overload Tolerance 165% of rated output current for 30 sec DC Reactor External Braking Transistor Built in Applicable Motor Types Induction Maximum Output Frequency Induction Motor: 120 Hz Output frequency resolution 0.001 Hz Starting Torque V/f control (IM): 150% @ 3 Hz Vector Control (IM): 150% @ 1 Hz CLV control (IM): 150% @ 0 rpm Speed Control Range V/f control (IM): 1:40 OLV control (IM): 1:100 CLV control (IM): 1:1500 Torque Limit Control Possible in Vector Control (IM), sensorless, 4 quadrants individually adjustable Acceleration/Deceleration Ramps 4 individual, 0 to 600 s linear, 4 separately adjustable S-curves Braking Torque Approx. 20% without braking resistor, approx. 125% with dynamic braking option V/f Pattern Freely adjustable Protection • Motor electronic thermistor function • Motor PTC input • Instantaneous over current at 200% of rated current • Drive over load 150% (HD) for 1 min, once per 10 min • DC over voltage at 820 Vdc (400 V units) • Output ground fault • Motor stall prevention Software Functions • Power outage ride through control • Brake Sequence • Light Load Search and Rescue Operation • Short Floor Function • Over-/under torque detection • 17-step multi-speed operation • Motor data auto-tuning rotating/in stop condition • Dwell function • Cooling fan control by heatsink temperature • Leveling Speed • Phase loss detection • Parameter copy function Ambient Conditions Place of Installation: • Indoors, no direct sunlight • free from oil, mist, flammable gases, metal powder, oil, water, salt, harmful gases and liquids, solvents Operation temperature: • IP20: -10 to +50°C (up to 60°C with derating) • UL type 1: -10 to +40°C • Side-by-Side mounting: -10 to +40°C (up to 50°C with derating) Storage temperature: -20 to +70°C Humidity: 95% RH, no condensation Overvoltage category: III Pollution degree: 2 or less Altitude: up to 1000m, up to 4000m with 1% current derating per 100 m LA500 Data Sheet | YASKAWA Europe GmbH 7

Source page

Page 9

Open in PDF

General specification

Vibration Resistance 10 to 20 Hz - 1 g (9.81 m/s2); 20 to 55 Hz - 0.6 g (5.9 m/s2) Standards • UL61800-5-1 • EN61800-2 • IEC/EN61800-5-1 • ISO/EN13849-1 Cat. III PLe, IEC/EN61508 SIL3 (2 Safety inputs, 1 EDM output) Enclosure • IP20 Communication • Modbus/Memobus embedded via built in RS485 interface, 115.2 kBps Programming Interface • Built in removable LED keypad with soft buttons • Built in USB mini port for connection a PC or Android Smart Device • Serial through keypad port (needs adapter) Programming Tools • DriveWizard 10 (Windows 10) • DriveWizard mobile (Android and iOS)

8 YASKAWA Europe GmbH | LA500 Data Sheet

Source page

Page 10

Open in PDF

Power Ratings

Power Ratings

200V Model 2019 2025 2033 2047 2060 2075 Model CIPR-LA50C... Maximum Applicable kW 4 5,5 7,5 11 15 18,5 Motor Capacity Rated Output Current Amp 17,6 25 33 47 60 75 Rated Output Capacity kVA 6,7 9,5 12,6 17,9 22,9 28,6

Rated Input Current (A) AC 18,9 24 37 52 68 96 Default Carrier kHz 8 8 8 8 8 8 Frequency DC Reactor External Option Braking Transistor Built-Iin

Three phase 200V to 240V Maximum Output Note: The maximum output voltage is proportional to the input Voltage voltage EMC Filter Built-in, category: C3 AC Power: Three phase 200V to 240V (-15% to +10%) at 50/60Hz Power Supply Allowable Frequency Fluctuation: ±5% DC Power: 270V to 340V Input Power kVA 8,7 11 17 24 31 44 400V Model 4009 4015 4018 4024 4031 4039 4045 Model CIPR-LA50C... Maximum Applicable kW 4 5,5 7,5 11 15 18,5 22 Motor Capacity Rated Output Current Amp 9,2 14,8 18 24 31 39 45 Rated Output Capacity kVA 7 11,3 13,7 18,3 23,6 29,7 34,3 Rated Input Current (A) AC 10,4 15 20 29 39 50,5 59,7

Default Carrier Frequency kHz 8 8 8 8 8 8 8

DC Reactor External Option

Braking Transistor Built-Iin

Three phase 380V to 480V Maximum Output Voltage Note: The maximum output voltage is proportional to the input voltage EMC Filter Built-in, category: C2 AC Power: Three phase 380V to 480V (-15% to +10%) at 50/60Hz Power Supply Allowable Frequency Fluctuation: ±5% DC Power: 513V to 679V Input Power kVA 9,5 14 18 27 36 47 55

LA500 Data Sheet | YASKAWA Europe GmbH 9

ColumnColumnColumn201920252033204720602075
Model CIPR-LA50C...
45,57,51115
17,625334760
6,79,512,617,922,9
18,924375268
88888
ColumnColumnColumn4009401540184024403140394045
Model CIPR-LA50C...
45,57,5111518,5
9,214,818243139
711,313,718,323,629,7
10,41520293950,5
888888

Source page

Page 11

Open in PDF

Integrated EMC Filters

Integrated EMC Filters

LA500 Drives are offered with or without an embedded EMC filter. Internal EMC filters are designed to be used in TN grids. The filters shall be disabled when using the drive in an ungrounded system or a system that is not grounded symmetrically.

Voltage Class IEC61800-3 Cable Leakage Model Category Length *1 Current *2 Three-phase 200V LA50C2019Exx / LA50C2075Exx C3 20 m 1.8 LA50C4009Exx C2 20 m 3.1 LA50C4015Exx / LA50C4018Exx C2 20 m 7.8 Three-phase 400 V LA50C4024Exx / LA50C4031Exx C2 20 m 1.9 LA50C4039Exx / LA50C4045Exx C2 20 m 7.8 *1 Shielded Motor Cable *2 Leakage currents shown here are calculated and for the EMC filter only. Values in real applications can vary depending on factors like phase voltage imbalance, grounding etc.

10 YASKAWA Europe GmbH | LA500 Data Sheet

Source page

Page 12

Open in PDF

Watt Loss

Watt Loss

200V Model

LA500 Drive Heat Losses (with EMC filter) Model CIPR- Carrier LA50C... Power Current Frequency Inside Outside Total Loss (W) (W) (W) (kHz) 2018 4 kW 17,5 A 8 41 108 149 2025 5,5 kW 25 A 8 50 187 237 2033 7,5 kW 33 A 8 61 232 293

2047 11 kW 47 A 8 86 318 404

2060 15 kW 60 A 8 120 473 593

2075 18,5 kW 75 A 8 149 525 674

400V Model

Model LA500 Drive Heat Losses CIPR- LA50C... Carrier Inside Outside Total Loss Power Current Frequency (kHz) (W) (W) (W) 4009 4 kW 9,2 A 8 55 116 171

4015 5,5 kW 14,8 A 8 63 141 204

4018 7,5 kW 18 A 8 93 206 299

4024 11 kW 24 A 8 121 286 407

4031 15 kW 31 A 8 132 331 463

4039 18,5 kW 39 A 8 141 365 506

4045 22 kW 45 A 8 188 497 685

LA500 Data Sheet | YASKAWA Europe GmbH 11

Model CIPR- LA50C...ColumnColumnLA500 Drive Heat Losses (with EMC filter)ColumnColumnColumn
PowerCurrentCarrier Frequency (kHz)Inside (W)Outside (W)Total Loss (W)
4 kW 17,5 A
20255,5 kW25 A850187237
7,5 kW 33 A
204711 kW47 A886318404
15 kW 60 A
207518,5 kW75 A8149525674
Inside
(W)
Outside
(W)
Total Loss
(W)
Model CIPR- LA50C...ColumnColumnLA500 Drive Heat LossesColumnColumnColumn
PowerCurrentCarrier Frequency (kHz)Inside (W)Outside (W)Total Loss (W)
4 kW 9,2 A
40155,5 kW14,8 A863141204
7,5 kW 18 A
402411 kW24 A8121286407
15 kW 31 A
403918,5 kW39 A8141365506
22 kW 45 A
Model
CIPR-
LA50C...
Inside
(W)
Outside
(W)
Total Loss
(W)

Source page

Page 13

Open in PDF

Deratings

Deratings

Carrier Frequency Derating

The rated current of LA500 drives might need to be reduced depending on the selected carrier frequency.

200V Model

Model LA500 Rated Output Current in Ampere CIPR- LA50C... Power Current 2 kHz 5 kHz 8 kHz 10 kHz 12.5 kHz 15 kHz 4009 4 kW 9,2 A 9,2 9,2 9,2 8,1 6,8 5,5

4015 5,5 kW 14,8 A 14,8 14,8 14,8 13,1 11 8,9

4018 7,5 kW 18 A 18 18 18 13,1 11 11

4024 11 kW 24 A 24 24 24 21,3 17,8 14

4031 15 kW 31 A 31 31 31 27,5 23 19

4039 18,5 kW 39 A 39 39 39 34,5 29 23

4045 22 kW 45 A 45 45 45 39,9 33,4 27

400V Model Model LA500 Rated Output Current in Ampere CIPR- LA50C... Power Current 2 kHz 5 kHz 8 kHz 10 kHz 12.5 kHz 15 kHz 4009 4 kW 9,2 A 9,2 9,2 9,2 8,1 6,8 5,5

4015 5,5 kW 14,8 A 14,8 14,8 14,8 13,1 11 8,9

4018 7,5 kW 18 A 18 18 18 13,1 11 11

4024 11 kW 24 A 24 24 24 21,3 17,8 14

4031 15 kW 31 A 31 31 31 27,5 23 19

4039 18,5 kW 39 A 39 39 39 34,5 29 23

4045 22 kW 45 A 45 45 45 39,9 33,4 27

12 YASKAWA Europe GmbH | LA500 Data Sheet

Model CIPR- LA50C...ColumnColumnLA500 Rated Output Current in AmpereColumnColumnColumnColumnColumn
PowerCurrent2 kHz5 kHz8 kHz10 kHz12.5 kHz15 kHz
4 kW 9,2 A
40155,5 kW14,8 A14,814,814,813,1118,9
7,5 kW 18 A
402411 kW24 A24242421,317,814
15 kW 31 A
403918,5 kW39 A39393934,52923
22 kW 45 A
Model CIPR- LA50C...ColumnColumnColumnLA500 Rated Output Current in AmpereColumnColumnColumnColumnColumn
Model
CIPR-
LA50C...PowerCurrent2 kHz5 kHz8 kHz10 kHz12.5 kHz15 kHz
4 kW 9,2 A
40155,5 kW14,8 A14,814,814,813,1118,9
7,5 kW 18 A
402411 kW24 A24242421,317,814
15 kW 31 A
403918,5 kW39 A39393934,52923
22 kW 45 A

Source page

Page 14

Open in PDF

Deratings

Ambient Temperature Derating

Depending on the mounting condition, enclosure type and ambient temperature derating factors

need to be applied on the rated output current of LA500 drives. The derating curves shown below are valid for all frames of LA500.

UL type 1 IP20 1

0.85 0.8 Heatsink external mounting 0.7 0.55 Side-by-side mounting

35 40 50 60 Ambient Temperature in °C

LA500 Data Sheet | YASKAWA Europe GmbH 13 rotcaf gnoitared tnerruc tuptuO Altitude Derating LA500 drives can be operated at altitudes up to 1000 m without derating. Between 1000 and 4000 m altitude above sea level a derating of 1 % per 100 m must be applied to the rated output current. Additionally, a derating must be applied to the rated voltage if the drive is installed over 2000 m above sea level with the neutral point of the power supply ungrounded.

ColumnHeatsink external mouColumnColumnntingColumnColumnColumn
Side-bmounting
Side-by-sidemounting

Source page

Page 15

Open in PDF

Electrical Connections

Electrical Connections

Connection Diagram

14 YASKAWA Europe GmbH | LA500 Data Sheet

Source page

Page 16

Open in PDF

Dimensions

Dimensions

200V Model Voltage Power Dimensions [mm] / Weight [kg] Model Class [kW] W H D D1 W1 W2 H1 H2 t1 d Weight 3x200V 4 LA50x2018 140 128 193 65 128 6 118 193 5 For M5 2.4 3x200V 5.5 LA50x2025 140 260 196 55 122 9 248 196 5 For M5 3.9 3x200V 7.5 LA50x2033 140 260 196 55 122 9 248 196 5 For M5 4.1 3x200V 11 LA50x2047 180 300 196 55 160 10 284 196 5 For M5 6 3x200V 15 LA50x2060 220 350 216 78 192 14 336 216 5 For M5 8.5 3x200V 18.5 LA50x2075 220 350 216 78 192 14 336 216 5 For M6 9 400V Model Voltage Power Dimensions [mm] / Weight [kg] Model Class [kW] W H D D1 W1 W2 H1 H2 t1 d Weight 3x400V 4 LA50x4009 140 128 193 65 128 6 118 5 5 For M5 2.6 3x400V 5.5 LA50x4015 140 260 196 55 122 9 248 6 5 For M5 3.9 3x400V 7.5 LA50x4018 140 260 196 55 122 9 248 6 5 For M5 3.9 3x400V 11 LA50x4024 180 300 196 55 160 10 284 8 5 For M5 5.5 3x400V 15 LA50x4031 180 300 196 55 160 10 284 8 5 For M5 5.5 3x400V 18.5 LA50x4039 190 350 251 94 160 15 336 7 5 For M6 8 3x400V 22 LA50x4044 190 350 251 94 160 15 336 7 5 For M6 8.5

LA500 Data Sheet | YASKAWA Europe GmbH 15

HDD1W1W2H1H2t1dWeight
1281936512861181935For M52.4
2601965512292481965For M53.9
2601965512292481965For M54.1
30019655160102841965For M56
35021678192143362165For M58.5
35021678192143362165For M69
HDD1W1W2H1H2t1dWeight
12819365128611855For M52.6
26019655122924865For M53.9
26019655122924865For M53.9
300196551601028485For M55.5
300196551601028485For M55.5
350251941601533675For M68
350251941601533675For M68.5

Source page

Page 17

Open in PDF

Accessories

Accessories

Motor Speed Feedback option

The LA500 is capable to control the motor in CLV mode. The required motor feedback option (encoder) should be of TTL type. To make brake control easier the LA500 motor speed feedback option series JOHB-PGX3-AE also includes one relay on the feedback card to connect the motor brake directly.

Option Model Number SAP# Motor Feedback JOHB-PGX3-AE 10114901 Motor Feedback Mounting KIT JOHB-GA50 10105392

Important: • The motor feedback mounting kit is not part of motor feedback option and must be ordered separately • With motor feedback option installed the depth of the drive increases for 27 mm • For LA500 units manufactured before 2025 a firmware upgrade (24013 or higher) will be required to support JOHB- PGX3-AE option card

Option enclosure (Model code: JOHB-GA50, parts A) and option card installation:

16 YASKAWA Europe GmbH | LA500 Data Sheet

ColumnModel NumberColumnColumnSAP#Column
JOHB-PGX3-AE10114901
JOHB-GA5010105392

Source page

Page 18

Open in PDF

Accessories

LED/LCD Keypads

LED Full Size Keypad Option Model Number SAP# LED Full Size Keypad JVOP-KPLEA04AAA 10010185

This optional LED keypad provides a larger LED display (5 digit, 7 segments) and larger navigation buttons for more comfort during drive operation.

LCD Keypad Option Model Number SAP# LCD Keypad JVOP-KPLCA04AEA 10105769

This optional LCD keypad greatly improves the operability of the drive. The high-res screen can display graphics and multi-language full text. Additional functions are: Start-up Wizard, copy function (4 sets of parameters), backup, data logging, real-time clock.

LCD Bluetooth Keypad Option Model Number SAP# LCD Bluetooth Keypad JVOP-KPLCC04ABA 10099085

This optional LCD keypad provides the ability to connect to the drive using Bluetooth. It is designed to be able to operate like the LCD keypad if keypad navigation is required.

This keypad is used in conjunction with DriveWizard Mobile to connect to the drive via Bluetooth. You can download DriveWizard Mobile to your mobile device through the Apple AppStore or Google Play.

Extension Cables Extension cables for keypads are offered in two lengths.

Model Number Description SAP# WV001-YEG Keypad Remote Mount Cable - 1 Meter 10007058 WV003-YEG Keypad Remote Mount Cable - 3 Meter 10012366

Appearance

LED Keypad LCD Keypad Extension Cable

LA500 Data Sheet | YASKAWA Europe GmbH 17

ColumnModel NumberColumnColumnSAP#Column
JVOP-KPLEA04AAA10010185
ColumnModel NumberColumnColumnSAP#Column
JVOP-KPLCA04AEA10105769
ColumnModel NumberColumnColumnSAP#Column
JVOP-KPLCC04ABA10099085
ColumnDescriptionColumnColumnSAP#Column
Keypad Remote Mount Cable - 1 Meter10007058
Keypad Remote Mount Cable - 3 Meter10012366

Source page

Page 19

Open in PDF

Accessories

Keypad Door Mounting Kits

Door Mounting Kit for LA500 Internal Keypad

The removable keypad on LA500 can be mounted on a panel door using the parts below. When mounting the keypad externally a blind cover should be applied to the drive. Cables WV001-YEG or WV003-YEG are recommended as extension cable.

Part Door mounting kit for LA500 integrated Blind cover for LA500 keypad Model Number ZPBA-GA500 JVOP-KPBCH04AAA SAP# 10106938 10106937

Appearance

(Door mounting kit does not contain a keypad, blind cover or cable!)

Door Mounting Kits for LCD Keypads (with or without Bluetooth)

The LCD keypads can be mounted to a panel front door using one of the mounting kits below.

Type of Mounting Brackets have tapped holes for use with brackets have untapped holes for use with screws panel studs Model Number 900-192-933-001 900-192-933-002 SAP# 10090514 10090515

Appearance

18 YASKAWA Europe GmbH | LA500 Data Sheet

ColumnDoor mounting kit for LA500 integratedColumnBlind cover for LA500ColumnColumn
keypad
ZPBA-GA500JVOP-KPBCH04AAA
1010693810106937
ColumnBrackets have tapped holes for use withColumnColumnbrackets have untapped holes for use withColumn
screwspanel studs
900-192-933-001900-192-933-002
1009051410090515

Source page

Page 20

Open in PDF

Accessories

Heatsink External Mounting Kit

LA500 drives with IP20 can be mounted with the heatsink out the back of the panel or enclosure in order to have the main source of heat loss outside and so reduce panel volume or panel cooling. A rectangular cut out is required in the panel. Drives are fixed using an heatsink external mounting kit. Details on assembly and installation can be found the Installation Manual for these kits (TOEPC72060009_).

Important: • With this method of mounting the rated output current might require a derating. See section “Deratings“ in this document. • The backside of the drive remains IP20. The externally mounted heatsink should not be exposed to dusty or wet environment that would normally require a higher degree of ingress protection.

Appearance

Heatsink External Mounting Kit Model Numbers

Voltage Power kW LA500 Model Heatsink External Mounting Kit SAP# Class 3x400V 4 LA50x4009xxx ZPSA-GA50V3-1 10105756 3x400V 5.5 LA50x4015xxx ZPSA-GA50V5-1 10105758 3x400V 7.5 LA50x4018xxx ZPSA-GA50V5-1 10105758 3x400V 11 LA50x4024xxx ZPSA-GA50V6-1 10105759 3x400V 15 LA50x4031xxx ZPSA-GA50V6-1 10105759 3x400V 18.5 LA50x4039xxx ZPSA-GA50V8-1 10105761 3x400V 22 LA50x4044xxx ZPSA-GA50V8-1 10105761

LA500 Data Sheet | YASKAWA Europe GmbH 19

LA500 ModelColumnColumnHeatsink External Mounting KitColumnColumnSAP#ColumnColumn
LA50x4009xxxZPSA-GA50V3-110105756
LA50x4015xxxZPSA-GA50V5-110105758
LA50x4018xxxZPSA-GA50V5-110105758
LA50x4024xxxZPSA-GA50V6-110105759
LA50x4031xxxZPSA-GA50V6-110105759
LA50x4039xxxZPSA-GA50V8-110105761
LA50x4044xxxZPSA-GA50V8-110105761

Source page

Page 21

Open in PDF

Accessories

Cable Shield Clamp Kit

A cable shield kit can be mounted at the bottom of the drive in order to easy cable shield connection and provide a strain relief at the same time.

Important: • Cable shield and UL Type 1 kits cannot be installed simultaneously.

Appearance

Cable Shield Kit Model Numbers Voltage Power kW LA500 Model Shield Clamp Kit SAP# Class (HD) 3x400V 4 LA50x4009xxx ZHZ-GA50V3 10108105 3x400V 5.5 LA50x4015xxx ZHZ-GA50V5 10108107 3x400V 7.5 LA50x4018xxx ZHZ-GA50V5 10108107 3x400V 11 LA50x4024xxx ZHZ-GA50V6 10108108 3x400V 15 LA50x4031xxx ZHZ-GA50V6 10108108 3x400V 18.5 LA50x4039xxx ZHZ-GA50V8 10108110 3x400V 22 LA50x4044xxx ZHZ-GA50V8 10108110

20 YASKAWA Europe GmbH | LA500 Data Sheet

LA500 ModelShield Clamp KitSAP#
LA50x4009xxxZHZ-GA50V310108105
LA50x4015xxxZHZ-GA50V510108107
LA50x4018xxxZHZ-GA50V510108107
LA50x4024xxxZHZ-GA50V610108108
LA50x4031xxxZHZ-GA50V610108108
LA50x4039xxxZHZ-GA50V810108110
LA50x4044xxxZHZ-GA50V810108110

Source page

Page 22

Open in PDF

Power Options

Power Options

AC Input Reactors

Input reactors can be applied in order to reduce harmonic distortion on the AC input line. Reactors are offered as IP00 protection. IP20 covers are separately available. 200V Model

Reactor SAP# LA500 Model IP00 IP20 cover IP00 IP20 cover LA50C2018xx LR3 40-4/20 IP20-Box32 10011010 10062614 LA50C2025xx LR3 40-4/45 IP20-Box35 10011017 10062617 LA50C2033xx LA50C2047xx LR3 40-4/70 IP20-Box37 10011021 10062619 LA50C2060xx LA50C2075xx LR3 40-4/90 IP20-Box39 10011023 10062621 400V Model Reactor SAP# LA500 Model IP00 IP20 cover IP00 IP20 cover LA50C4009xxx B 1103136 IP20-Box32 10008858 10062614 LA50C4015xxx B 1103138 IP20-Box35 10000040 10062617 LA50C4018xxx LA50C4024xxx B 1103139 IP20-Box35 10000041 10062617 LA50C4031xxx B 1103140 IP20-Box37 10000042 10062619 LA50C4038xxx B 1103141 IP20-Box39 10008862 10062621 LA50C4045xxx B 1103142 IP20-Box39 10008863 10062621

LA500 Data Sheet | YASKAWA Europe GmbH 21

ColumnReactorColumnColumnColumnColumnColumnSAP#ColumnColumnColumnColumn
IP00IP20 coverIP00IP20 cover
LR3 40-4/20IP20-Box321001101010062614
LR3 40-4/45IP20-Box351001101710062617
LR3 40-4/70IP20-Box371001102110062619
LR3 40-4/90IP20-Box391001102310062621
ColumnReactorColumnColumnColumnColumnColumnSAP#ColumnColumnColumnColumn
IP00IP20 coverIP00IP20 cover
B 1103136IP20-Box321000885810062614
B 1103138IP20-Box351000004010062617
B 1103139IP20-Box351000004110062617
B 1103140IP20-Box371000004210062619
B 1103141IP20-Box391000886210062621
B 1103142IP20-Box391000886310062621

Source page

Page 23

Open in PDF

Power Options

Braking Resistors

LA500 drives have embedded braking transistors. Resistors selected from the table below can be directly connected to terminals B1 and B2. When connecting with other resistors, the resistance must be higher than the minimum value listed below.

200V Model Minimum Resistor LA500 Model Resistor SAP# 40% ED (Ohm) LA50C2018xx RH-1560W040 32 10004350 LA50C2025xx RH-2700W025 9,6 10004351 LA50C2033xx RH-2700W025 9,6 10004351 LA50C2047xx RH-9600W015 9,6 10004358 LA50C2060xx RH-9600W015 9,6 10004358 LA50C2075xx RH-9600W015 9,6 10004358

400V Model

Minimum Resistor LA500 Model Resistor SAP# 40% ED (Ohm) LA50C4009xx RH-1000W120 100 10004349 LA50C4015xx RH-1560W040 32 10004350 LA50C4018xx RH-1560W040 32 10004350 LA50C4024xx RH-2700W025 20 10004351 LA50C4031xx RH-3700W025 20 10004352 LA50C4038xx RH-4800W022 19,2 10004353 LA50C4045xx RH-6000W022 19,2 10004356 • 40% ED : 120 s cycle time (t) and 48 s switch on time (ton) Rate of

22 YASKAWA Europe GmbH | LA500 Data Sheet

Resistor 40% EDColumnColumnColumnMinimumColumnSAP#ColumnColumn
Resistor
(Ohm)
RH-1560W0403210004350
RH-2700W0259,610004351
RH-2700W0259,610004351
RH-9600W0159,610004358
RH-9600W0159,610004358
RH-9600W0159,610004358
Resistor
40% ED
Resistor 40% EDColumnColumnColumnMinimumColumnSAP#ColumnColumn
Resistor
(Ohm)
RH-1000W12010010004349
RH-1560W0403210004350
RH-1560W0403210004350
RH-2700W0252010004351
RH-3700W0252010004352
RH-4800W02219,210004353
RH-6000W02219,210004356
Resistor
40% ED

Source page

Page 24

Open in PDF

Tools and Software

Tools and Software

Tools Tool Description System Connection DriveWizard 10 PC Tool for parameter Windows USB-mini management/backup/diagnostics DriveWizard Mobile app for parameter Android • Bluetooth Mobile management/backup/diagnostics • USB-mini with USB on-the- go adapter

iPhone • Bluetooth

Connection Cables Model Number Description SAP# JZSP-CVS06-02-E USB-mini connection cable for PC 2.5m 300-100-888

LA500 Data Sheet | YASKAWA Europe GmbH 23

Source page

Page 25

Open in PDF

LA500 Lift Inverter

THE NEW REFERENCE IN COMPACT LIFT DRIVE

Document: LA500 Data sheet_EN_v04 Published: April 10, 2026

Technical data

Highlighted specifications

SpecificationValuePage
TypeModel CIPR- LA50C... | Power | Current | Model Code | SAP#7
Model CIPR- LA50C...LA500 Drive Heat Losses (with EMC filter)12
Model CIPR- LA50C...LA500 Drive Heat Losses12
Model CIPR- LA50C...LA500 Rated Output Current in Ampere13
Side-bmounting14
LA500 ModelHeatsink External Mounting Kit | SAP#20
LA500 ModelShield Clamp Kit | SAP#21
LA50x4009xxxZHZ-GA50V3 | 1010810521
LA50x4015xxxZHZ-GA50V5 | 1010810721
LA50x4018xxxZHZ-GA50V5 | 1010810721
LA50x4024xxxZHZ-GA50V6 | 1010810821
LA50x4031xxxZHZ-GA50V6 | 1010810821
LA50x4039xxxZHZ-GA50V8 | 1010811021
LA50x4044xxxZHZ-GA50V8 | 1010811021
LR3 40-4/45IP20-Box35 | 10011017 | 1006261722
LR3 40-4/70IP20-Box37 | 10011021 | 1006261922
Resistor 40% EDMinimum | SAP#23