Page 1
LA500 Data Sheet
AC Compact Drive for Lift Applications
Data Sheet
Type: CIPR-LA50Cxxxxxxxx
200 V Class, Three-Phase Input: 4 to 18.5 kW 400 V Class, Three-Phase Input: 4 to 18.5 kW
Source page
Page 2
Copyright © 2025 YASKAWA Europe GmbH All rights reserved. No part of this publication may be reproduced, stored in a retrieval system, or transmitted, in any form or by any means, mechanical, electronic, photocopying, recording, or otherwise, without the prior written permission of Yaskawa. No patent liability is assumed with respect to the use of the information contained herein. Moreover, because Yaskawa is constantly striving to improve its high-quality products, the information contained in this manual is subject to change without notice. Every precaution has been taken in the preparation of this manual. Yaskawa assumes no responsibility for errors or omissions. Neither is any liability assumed for damages resulting from the use of the information contained in this publication.
Source page
Page 3
This page is available in the source PDF.
Source page
Page 4
Contents
Introduction .............................................................................................................................................. 4
Drive Selection......................................................................................................................................... 4 Model Designation ............................................................................................................................... 5
List of Models ....................................................................................................................................... 6 General specification ............................................................................................................................... 7 Power Ratings ......................................................................................................................................... 9
Integrated EMC Filters ........................................................................................................................... 10 Watt Loss ............................................................................................................................................... 11
Deratings ............................................................................................................................................... 12 Carrier Frequency Derating ............................................................................................................... 12 Ambient Temperature Derating.......................................................................................................... 13
Altitude Derating ................................................................................................................................ 13 Electrical Connections ........................................................................................................................... 14
Connection Diagram .......................................................................................................................... 14 Dimensions ............................................................................................................................................ 15 Accessories ........................................................................................................................................... 16
Motor Speed Feedback option ........................................................................................................... 16 LED/LCD Keypads ............................................................................................................................. 17
Keypad Door Mounting Kits ............................................................................................................... 18 Heatsink External Mounting Kit .......................................................................................................... 19 Cable Shield Clamp Kit ...................................................................................................................... 20
Power Options ....................................................................................................................................... 21 AC Input Reactors .............................................................................................................................. 21
Braking Resistors ............................................................................................................................... 22 Tools and Software ................................................................................................................................ 23 Tools .................................................................................................................................................. 23
Connection Cables ............................................................................................................................. 23
Source page
Page 5
Introduction
LA500 is a dedicated drive for lift applications. The key attributes are ease of use, flexibility and sustainability. Loaded with valuable features and functions the LA500 drives greatly simplifies system designs and maximize system and machine performance while reducing the effort for installation and setup to a minimum.
LA500 Online Info
Drive Selection
LA500 drives must be selected according to power supply voltage, motor rated current, load profile of the application, and ambient condition of the area they are operated in. LA500 standard drives are rated for Heavy Duty applications. In Heavy Duty the LA500 can run applications with constant torque and heavy overload of up to 165% for 30 seconds.
LA500 drives are designed to be wall mounted upright and in clean environmental condition. In case of special mounting methods (heatsink external, horizontal, etc.), high ambient temperature (>50 °C), high altitude (> 1000 m), use of high carrier frequency, and so forth, an output current derating must be considered when selecting the drive.
4 YASKAWA Europe GmbH | LA500 Data Sheet
Source page
Page 6
Drive Selection
Model Designation
The following diagram and table describe how to read model number of the lift drive.
CIPR - LA50 C 4 005 E B A B
1 2 3 4 5 6 7 8 9
No. Description
1 Drive Series
Product Series 2 • LA50: LA500
Region code 3 • C: Europe
Voltage class 4 • 2: 200V 3-phase • 4: 400V 3-phase
Rated output current 5 Note: Refer to the list of models EMC filter • A: no built-in EMC filter 6 • E: Built-in EMC filter (400V: C2, 20m; 200V: C3,20m) Enclosure design 7 • B: IP20
Environmental specification 8 • A: Standard Design revision order 9 • A: Without SIL3 STO function • B: With SIL3 STO function
LA500 Data Sheet | YASKAWA Europe GmbH 5
| Column | No. | Column | Column | Description | Column |
|---|---|---|---|---|---|
| 1 | Drive Series | ||||
| 2 | Product Series • LA50: LA500 | ||||
| 3 | Region code • C: Europe | ||||
| 4 | Voltage class • 2: 200V 3-phase • 4: 400V 3-phase | ||||
| 5 | Rated output current Note: Refer to the list of models | ||||
| 6 | EMC filter • A: no built-in EMC filter • E: Built-in EMC filter (400V: C2, 20m; 200V: C3,20m) | ||||
| 7 | Enclosure design • B: IP20 | ||||
| 8 | Environmental specification • A: Standard | ||||
| 9 | Design revision order • A: Without SIL3 STO function • B: With SIL3 STO function |
Source page
Page 7
Drive Selection
List of Models
200V Model Type Model CIPR- Power Current Model Code SAP# LA50C... LA500 2019 4 kW 17,5 A CIPR-LA50C2019EBAB 10113982
LA500 2025 5,5 kW 25 A CIPR-LA50C2025EBAB 10113983
LA500 2033 7,5 kW 33 A CIPR-LA50C2033EBAB 10113984
LA500 2047 11 kW 47 A CIPR-LA50C2047EBAB 10113985
LA500 2060 15 kW 60 A CIPR-LA50C2060EBAB 10113986 LA500 2075 18,5 kW 75 A CIPR-LA50C2075EBAB 10113987
400V Model
Type Model CIPR- Power Current Model Code SAP# LA50C... LA500 4009 4 kW 9,2 A CIPR-LA50C4009EBAB 10113988
LA500 4015 5,5 kW 14,8 A CIPR-LA50C4015EBAB 10113989
LA500 4018 7,5 kW 18 A CIPR-LA50C4018EBAB 10113990
LA500 4024 11 kW 24 A CIPR-LA50C4024EBAB 10113991 LA500 4031 15 kW 31 A CIPR-LA50C4031EBAB 10113992
LA500 4039 18,5 kW 39 A CIPR-LA50C4039EBAB 10113993
LA500 4045 22 kW 45 A CIPR-LA50C4045EBAB 10113994
6 YASKAWA Europe GmbH | LA500 Data Sheet
| Type | Model CIPR- LA50C... | Power | Current | Model Code | SAP# |
|---|---|---|---|---|---|
| 2019 4 kW | 17,5 A | CIPR-LA50C2019EBAB | 10113982 | ||
| 2025 5,5 kW | 25 A | CIPR-LA50C2025EBAB | 10113983 | ||
| 2033 7,5 kW | 33 A | CIPR-LA50C2033EBAB | 10113984 | ||
| 2047 11 kW | 47 A | CIPR-LA50C2047EBAB | 10113985 | ||
| 2060 15 kW | 60 A | CIPR-LA50C2060EBAB | 10113986 | ||
| 2075 18,5 kW | 75 A | CIPR-LA50C2075EBAB | 10113987 |
| Model CIPR- |
|---|
| LA50C... |
| Type | Model CIPR- LA50C... | Power | Current | Model Code | SAP# |
|---|---|---|---|---|---|
| 4009 4 kW | 9,2 A | CIPR-LA50C4009EBAB | 10113988 | ||
| 4015 5,5 kW | 14,8 A | CIPR-LA50C4015EBAB | 10113989 | ||
| 4018 7,5 kW | 18 A | CIPR-LA50C4018EBAB | 10113990 | ||
| 4024 11 kW | 24 A | CIPR-LA50C4024EBAB | 10113991 | ||
| 4031 15 kW | 31 A | CIPR-LA50C4031EBAB | 10113992 | ||
| 4039 18,5 kW | 39 A | CIPR-LA50C4039EBAB | 10113993 | ||
| 4045 22 kW | 45 A | CIPR-LA50C4045EBAB | 10113994 |
| Model CIPR- |
|---|
| LA50C... |
Source page
Page 8
General specification
General specification
Item Description Product Name LA500 Power Range 3-phase 200~240 V: 4 to 18.5 kW 3-phase 380~400 V: 4 to 18.5 kW Rated Input Frequency 50 Hz Allowable Voltage Fluctuation -15 to +10% Allowable Frequency Fluctuation ±5% DC Supply 200 V class: 270 to 340 Vdc 400 V class: 513 to 679 Vdc Overload Tolerance 165% of rated output current for 30 sec DC Reactor External Braking Transistor Built in Applicable Motor Types Induction Maximum Output Frequency Induction Motor: 120 Hz Output frequency resolution 0.001 Hz Starting Torque V/f control (IM): 150% @ 3 Hz Vector Control (IM): 150% @ 1 Hz CLV control (IM): 150% @ 0 rpm Speed Control Range V/f control (IM): 1:40 OLV control (IM): 1:100 CLV control (IM): 1:1500 Torque Limit Control Possible in Vector Control (IM), sensorless, 4 quadrants individually adjustable Acceleration/Deceleration Ramps 4 individual, 0 to 600 s linear, 4 separately adjustable S-curves Braking Torque Approx. 20% without braking resistor, approx. 125% with dynamic braking option V/f Pattern Freely adjustable Protection • Motor electronic thermistor function • Motor PTC input • Instantaneous over current at 200% of rated current • Drive over load 150% (HD) for 1 min, once per 10 min • DC over voltage at 820 Vdc (400 V units) • Output ground fault • Motor stall prevention Software Functions • Power outage ride through control • Brake Sequence • Light Load Search and Rescue Operation • Short Floor Function • Over-/under torque detection • 17-step multi-speed operation • Motor data auto-tuning rotating/in stop condition • Dwell function • Cooling fan control by heatsink temperature • Leveling Speed • Phase loss detection • Parameter copy function Ambient Conditions Place of Installation: • Indoors, no direct sunlight • free from oil, mist, flammable gases, metal powder, oil, water, salt, harmful gases and liquids, solvents Operation temperature: • IP20: -10 to +50°C (up to 60°C with derating) • UL type 1: -10 to +40°C • Side-by-Side mounting: -10 to +40°C (up to 50°C with derating) Storage temperature: -20 to +70°C Humidity: 95% RH, no condensation Overvoltage category: III Pollution degree: 2 or less Altitude: up to 1000m, up to 4000m with 1% current derating per 100 m LA500 Data Sheet | YASKAWA Europe GmbH 7
Source page
Page 9
General specification
Vibration Resistance 10 to 20 Hz - 1 g (9.81 m/s2); 20 to 55 Hz - 0.6 g (5.9 m/s2) Standards • UL61800-5-1 • EN61800-2 • IEC/EN61800-5-1 • ISO/EN13849-1 Cat. III PLe, IEC/EN61508 SIL3 (2 Safety inputs, 1 EDM output) Enclosure • IP20 Communication • Modbus/Memobus embedded via built in RS485 interface, 115.2 kBps Programming Interface • Built in removable LED keypad with soft buttons • Built in USB mini port for connection a PC or Android Smart Device • Serial through keypad port (needs adapter) Programming Tools • DriveWizard 10 (Windows 10) • DriveWizard mobile (Android and iOS)
8 YASKAWA Europe GmbH | LA500 Data Sheet
Source page
Page 10
Power Ratings
Power Ratings
200V Model 2019 2025 2033 2047 2060 2075 Model CIPR-LA50C... Maximum Applicable kW 4 5,5 7,5 11 15 18,5 Motor Capacity Rated Output Current Amp 17,6 25 33 47 60 75 Rated Output Capacity kVA 6,7 9,5 12,6 17,9 22,9 28,6
Rated Input Current (A) AC 18,9 24 37 52 68 96 Default Carrier kHz 8 8 8 8 8 8 Frequency DC Reactor External Option Braking Transistor Built-Iin
Three phase 200V to 240V Maximum Output Note: The maximum output voltage is proportional to the input Voltage voltage EMC Filter Built-in, category: C3 AC Power: Three phase 200V to 240V (-15% to +10%) at 50/60Hz Power Supply Allowable Frequency Fluctuation: ±5% DC Power: 270V to 340V Input Power kVA 8,7 11 17 24 31 44 400V Model 4009 4015 4018 4024 4031 4039 4045 Model CIPR-LA50C... Maximum Applicable kW 4 5,5 7,5 11 15 18,5 22 Motor Capacity Rated Output Current Amp 9,2 14,8 18 24 31 39 45 Rated Output Capacity kVA 7 11,3 13,7 18,3 23,6 29,7 34,3 Rated Input Current (A) AC 10,4 15 20 29 39 50,5 59,7
Default Carrier Frequency kHz 8 8 8 8 8 8 8
DC Reactor External Option
Braking Transistor Built-Iin
Three phase 380V to 480V Maximum Output Voltage Note: The maximum output voltage is proportional to the input voltage EMC Filter Built-in, category: C2 AC Power: Three phase 380V to 480V (-15% to +10%) at 50/60Hz Power Supply Allowable Frequency Fluctuation: ±5% DC Power: 513V to 679V Input Power kVA 9,5 14 18 27 36 47 55
LA500 Data Sheet | YASKAWA Europe GmbH 9
| Column | Column | Column | 2019 | 2025 | 2033 | 2047 | 2060 | 2075 |
|---|---|---|---|---|---|---|---|---|
| Model CIPR-LA50C... | ||||||||
| 4 | 5,5 | 7,5 | 11 | 15 | ||||
| 17,6 | 25 | 33 | 47 | 60 | ||||
| 6,7 | 9,5 | 12,6 | 17,9 | 22,9 | ||||
| 18,9 | 24 | 37 | 52 | 68 | ||||
| 8 | 8 | 8 | 8 | 8 |
| Column | Column | Column | 4009 | 4015 | 4018 | 4024 | 4031 | 4039 | 4045 |
|---|---|---|---|---|---|---|---|---|---|
| Model CIPR-LA50C... | |||||||||
| 4 | 5,5 | 7,5 | 11 | 15 | 18,5 | ||||
| 9,2 | 14,8 | 18 | 24 | 31 | 39 | ||||
| 7 | 11,3 | 13,7 | 18,3 | 23,6 | 29,7 | ||||
| 10,4 | 15 | 20 | 29 | 39 | 50,5 | ||||
| 8 | 8 | 8 | 8 | 8 | 8 |
Source page
Page 11
Integrated EMC Filters
Integrated EMC Filters
LA500 Drives are offered with or without an embedded EMC filter. Internal EMC filters are designed to be used in TN grids. The filters shall be disabled when using the drive in an ungrounded system or a system that is not grounded symmetrically.
Voltage Class IEC61800-3 Cable Leakage Model Category Length *1 Current *2 Three-phase 200V LA50C2019Exx / LA50C2075Exx C3 20 m 1.8 LA50C4009Exx C2 20 m 3.1 LA50C4015Exx / LA50C4018Exx C2 20 m 7.8 Three-phase 400 V LA50C4024Exx / LA50C4031Exx C2 20 m 1.9 LA50C4039Exx / LA50C4045Exx C2 20 m 7.8 *1 Shielded Motor Cable *2 Leakage currents shown here are calculated and for the EMC filter only. Values in real applications can vary depending on factors like phase voltage imbalance, grounding etc.
10 YASKAWA Europe GmbH | LA500 Data Sheet
Source page
Page 12
Watt Loss
Watt Loss
200V Model
LA500 Drive Heat Losses (with EMC filter) Model CIPR- Carrier LA50C... Power Current Frequency Inside Outside Total Loss (W) (W) (W) (kHz) 2018 4 kW 17,5 A 8 41 108 149 2025 5,5 kW 25 A 8 50 187 237 2033 7,5 kW 33 A 8 61 232 293
2047 11 kW 47 A 8 86 318 404
2060 15 kW 60 A 8 120 473 593
2075 18,5 kW 75 A 8 149 525 674
400V Model
Model LA500 Drive Heat Losses CIPR- LA50C... Carrier Inside Outside Total Loss Power Current Frequency (kHz) (W) (W) (W) 4009 4 kW 9,2 A 8 55 116 171
4015 5,5 kW 14,8 A 8 63 141 204
4018 7,5 kW 18 A 8 93 206 299
4024 11 kW 24 A 8 121 286 407
4031 15 kW 31 A 8 132 331 463
4039 18,5 kW 39 A 8 141 365 506
4045 22 kW 45 A 8 188 497 685
LA500 Data Sheet | YASKAWA Europe GmbH 11
| Model CIPR- LA50C... | Column | Column | LA500 Drive Heat Losses (with EMC filter) | Column | Column | Column |
|---|---|---|---|---|---|---|
| Power | Current | Carrier Frequency (kHz) | Inside (W) | Outside (W) | Total Loss (W) | |
| 4 kW 17,5 A | ||||||
| 2025 | 5,5 kW | 25 A | 8 | 50 | 187 | 237 |
| 7,5 kW 33 A | ||||||
| 2047 | 11 kW | 47 A | 8 | 86 | 318 | 404 |
| 15 kW 60 A | ||||||
| 2075 | 18,5 kW | 75 A | 8 | 149 | 525 | 674 |
| Inside |
|---|
| (W) |
| Outside |
|---|
| (W) |
| Total Loss |
|---|
| (W) |
| Model CIPR- LA50C... | Column | Column | LA500 Drive Heat Losses | Column | Column | Column |
|---|---|---|---|---|---|---|
| Power | Current | Carrier Frequency (kHz) | Inside (W) | Outside (W) | Total Loss (W) | |
| 4 kW 9,2 A | ||||||
| 4015 | 5,5 kW | 14,8 A | 8 | 63 | 141 | 204 |
| 7,5 kW 18 A | ||||||
| 4024 | 11 kW | 24 A | 8 | 121 | 286 | 407 |
| 15 kW 31 A | ||||||
| 4039 | 18,5 kW | 39 A | 8 | 141 | 365 | 506 |
| 22 kW 45 A |
| Model |
|---|
| CIPR- |
| LA50C... |
| Inside |
|---|
| (W) |
| Outside |
|---|
| (W) |
| Total Loss |
|---|
| (W) |
Source page
Page 13
Deratings
Deratings
Carrier Frequency Derating
The rated current of LA500 drives might need to be reduced depending on the selected carrier frequency.
200V Model
Model LA500 Rated Output Current in Ampere CIPR- LA50C... Power Current 2 kHz 5 kHz 8 kHz 10 kHz 12.5 kHz 15 kHz 4009 4 kW 9,2 A 9,2 9,2 9,2 8,1 6,8 5,5
4015 5,5 kW 14,8 A 14,8 14,8 14,8 13,1 11 8,9
4018 7,5 kW 18 A 18 18 18 13,1 11 11
4024 11 kW 24 A 24 24 24 21,3 17,8 14
4031 15 kW 31 A 31 31 31 27,5 23 19
4039 18,5 kW 39 A 39 39 39 34,5 29 23
4045 22 kW 45 A 45 45 45 39,9 33,4 27
400V Model Model LA500 Rated Output Current in Ampere CIPR- LA50C... Power Current 2 kHz 5 kHz 8 kHz 10 kHz 12.5 kHz 15 kHz 4009 4 kW 9,2 A 9,2 9,2 9,2 8,1 6,8 5,5
4015 5,5 kW 14,8 A 14,8 14,8 14,8 13,1 11 8,9
4018 7,5 kW 18 A 18 18 18 13,1 11 11
4024 11 kW 24 A 24 24 24 21,3 17,8 14
4031 15 kW 31 A 31 31 31 27,5 23 19
4039 18,5 kW 39 A 39 39 39 34,5 29 23
4045 22 kW 45 A 45 45 45 39,9 33,4 27
12 YASKAWA Europe GmbH | LA500 Data Sheet
| Model CIPR- LA50C... | Column | Column | LA500 Rated Output Current in Ampere | Column | Column | Column | Column | Column |
|---|---|---|---|---|---|---|---|---|
| Power | Current | 2 kHz | 5 kHz | 8 kHz | 10 kHz | 12.5 kHz | 15 kHz | |
| 4 kW 9,2 A | ||||||||
| 4015 | 5,5 kW | 14,8 A | 14,8 | 14,8 | 14,8 | 13,1 | 11 | 8,9 |
| 7,5 kW 18 A | ||||||||
| 4024 | 11 kW | 24 A | 24 | 24 | 24 | 21,3 | 17,8 | 14 |
| 15 kW 31 A | ||||||||
| 4039 | 18,5 kW | 39 A | 39 | 39 | 39 | 34,5 | 29 | 23 |
| 22 kW 45 A |
| Model CIPR- LA50C... | Column | Column | Column | LA500 Rated Output Current in Ampere | Column | Column | Column | Column | Column |
|---|---|---|---|---|---|---|---|---|---|
| Model | |||||||||
| CIPR- | |||||||||
| LA50C... | Power | Current | 2 kHz | 5 kHz | 8 kHz | 10 kHz | 12.5 kHz | 15 kHz | |
| 4 kW 9,2 A | |||||||||
| 4015 | 5,5 kW | 14,8 A | 14,8 | 14,8 | 14,8 | 13,1 | 11 | 8,9 | |
| 7,5 kW 18 A | |||||||||
| 4024 | 11 kW | 24 A | 24 | 24 | 24 | 21,3 | 17,8 | 14 | |
| 15 kW 31 A | |||||||||
| 4039 | 18,5 kW | 39 A | 39 | 39 | 39 | 34,5 | 29 | 23 | |
| 22 kW 45 A |
Source page
Page 14
Deratings
Ambient Temperature Derating
Depending on the mounting condition, enclosure type and ambient temperature derating factors
need to be applied on the rated output current of LA500 drives. The derating curves shown below are valid for all frames of LA500.
UL type 1 IP20 1
0.85 0.8 Heatsink external mounting 0.7 0.55 Side-by-side mounting
35 40 50 60 Ambient Temperature in °C
LA500 Data Sheet | YASKAWA Europe GmbH 13 rotcaf gnoitared tnerruc tuptuO Altitude Derating LA500 drives can be operated at altitudes up to 1000 m without derating. Between 1000 and 4000 m altitude above sea level a derating of 1 % per 100 m must be applied to the rated output current. Additionally, a derating must be applied to the rated voltage if the drive is installed over 2000 m above sea level with the neutral point of the power supply ungrounded.
| Column | Heatsink external mou | Column | Column | nting | Column | Column | Column |
|---|---|---|---|---|---|---|---|
| Side-b | mounting | ||||||
| Side-b | y-side | mounting |
Source page
Page 15
Electrical Connections
Electrical Connections
Connection Diagram
14 YASKAWA Europe GmbH | LA500 Data Sheet
Source page
Page 16
Dimensions
Dimensions
200V Model Voltage Power Dimensions [mm] / Weight [kg] Model Class [kW] W H D D1 W1 W2 H1 H2 t1 d Weight 3x200V 4 LA50x2018 140 128 193 65 128 6 118 193 5 For M5 2.4 3x200V 5.5 LA50x2025 140 260 196 55 122 9 248 196 5 For M5 3.9 3x200V 7.5 LA50x2033 140 260 196 55 122 9 248 196 5 For M5 4.1 3x200V 11 LA50x2047 180 300 196 55 160 10 284 196 5 For M5 6 3x200V 15 LA50x2060 220 350 216 78 192 14 336 216 5 For M5 8.5 3x200V 18.5 LA50x2075 220 350 216 78 192 14 336 216 5 For M6 9 400V Model Voltage Power Dimensions [mm] / Weight [kg] Model Class [kW] W H D D1 W1 W2 H1 H2 t1 d Weight 3x400V 4 LA50x4009 140 128 193 65 128 6 118 5 5 For M5 2.6 3x400V 5.5 LA50x4015 140 260 196 55 122 9 248 6 5 For M5 3.9 3x400V 7.5 LA50x4018 140 260 196 55 122 9 248 6 5 For M5 3.9 3x400V 11 LA50x4024 180 300 196 55 160 10 284 8 5 For M5 5.5 3x400V 15 LA50x4031 180 300 196 55 160 10 284 8 5 For M5 5.5 3x400V 18.5 LA50x4039 190 350 251 94 160 15 336 7 5 For M6 8 3x400V 22 LA50x4044 190 350 251 94 160 15 336 7 5 For M6 8.5
LA500 Data Sheet | YASKAWA Europe GmbH 15
| H | D | D1 | W1 | W2 | H1 | H2 | t1 | d | Weight |
|---|---|---|---|---|---|---|---|---|---|
| 128 | 193 | 65 | 128 | 6 | 118 | 193 | 5 | For M5 | 2.4 |
| 260 | 196 | 55 | 122 | 9 | 248 | 196 | 5 | For M5 | 3.9 |
| 260 | 196 | 55 | 122 | 9 | 248 | 196 | 5 | For M5 | 4.1 |
| 300 | 196 | 55 | 160 | 10 | 284 | 196 | 5 | For M5 | 6 |
| 350 | 216 | 78 | 192 | 14 | 336 | 216 | 5 | For M5 | 8.5 |
| 350 | 216 | 78 | 192 | 14 | 336 | 216 | 5 | For M6 | 9 |
| H | D | D1 | W1 | W2 | H1 | H2 | t1 | d | Weight |
|---|---|---|---|---|---|---|---|---|---|
| 128 | 193 | 65 | 128 | 6 | 118 | 5 | 5 | For M5 | 2.6 |
| 260 | 196 | 55 | 122 | 9 | 248 | 6 | 5 | For M5 | 3.9 |
| 260 | 196 | 55 | 122 | 9 | 248 | 6 | 5 | For M5 | 3.9 |
| 300 | 196 | 55 | 160 | 10 | 284 | 8 | 5 | For M5 | 5.5 |
| 300 | 196 | 55 | 160 | 10 | 284 | 8 | 5 | For M5 | 5.5 |
| 350 | 251 | 94 | 160 | 15 | 336 | 7 | 5 | For M6 | 8 |
| 350 | 251 | 94 | 160 | 15 | 336 | 7 | 5 | For M6 | 8.5 |
Source page
Page 17
Accessories
Accessories
Motor Speed Feedback option
The LA500 is capable to control the motor in CLV mode. The required motor feedback option (encoder) should be of TTL type. To make brake control easier the LA500 motor speed feedback option series JOHB-PGX3-AE also includes one relay on the feedback card to connect the motor brake directly.
Option Model Number SAP# Motor Feedback JOHB-PGX3-AE 10114901 Motor Feedback Mounting KIT JOHB-GA50 10105392
Important: • The motor feedback mounting kit is not part of motor feedback option and must be ordered separately • With motor feedback option installed the depth of the drive increases for 27 mm • For LA500 units manufactured before 2025 a firmware upgrade (24013 or higher) will be required to support JOHB- PGX3-AE option card
Option enclosure (Model code: JOHB-GA50, parts A) and option card installation:
16 YASKAWA Europe GmbH | LA500 Data Sheet
| Column | Model Number | Column | Column | SAP# | Column |
|---|---|---|---|---|---|
| JOHB-PGX3-AE | 10114901 | ||||
| JOHB-GA50 | 10105392 |
Source page
Page 18
Accessories
LED/LCD Keypads
LED Full Size Keypad Option Model Number SAP# LED Full Size Keypad JVOP-KPLEA04AAA 10010185
This optional LED keypad provides a larger LED display (5 digit, 7 segments) and larger navigation buttons for more comfort during drive operation.
LCD Keypad Option Model Number SAP# LCD Keypad JVOP-KPLCA04AEA 10105769
This optional LCD keypad greatly improves the operability of the drive. The high-res screen can display graphics and multi-language full text. Additional functions are: Start-up Wizard, copy function (4 sets of parameters), backup, data logging, real-time clock.
LCD Bluetooth Keypad Option Model Number SAP# LCD Bluetooth Keypad JVOP-KPLCC04ABA 10099085
This optional LCD keypad provides the ability to connect to the drive using Bluetooth. It is designed to be able to operate like the LCD keypad if keypad navigation is required.
This keypad is used in conjunction with DriveWizard Mobile to connect to the drive via Bluetooth. You can download DriveWizard Mobile to your mobile device through the Apple AppStore or Google Play.
Extension Cables Extension cables for keypads are offered in two lengths.
Model Number Description SAP# WV001-YEG Keypad Remote Mount Cable - 1 Meter 10007058 WV003-YEG Keypad Remote Mount Cable - 3 Meter 10012366
Appearance
LED Keypad LCD Keypad Extension Cable
LA500 Data Sheet | YASKAWA Europe GmbH 17
| Column | Model Number | Column | Column | SAP# | Column |
|---|---|---|---|---|---|
| JVOP-KPLEA04AAA | 10010185 |
| Column | Model Number | Column | Column | SAP# | Column |
|---|---|---|---|---|---|
| JVOP-KPLCA04AEA | 10105769 |
| Column | Model Number | Column | Column | SAP# | Column |
|---|---|---|---|---|---|
| JVOP-KPLCC04ABA | 10099085 |
| Column | Description | Column | Column | SAP# | Column |
|---|---|---|---|---|---|
| Keypad Remote Mount Cable - 1 Meter | 10007058 | ||||
| Keypad Remote Mount Cable - 3 Meter | 10012366 |
Source page
Page 19
Accessories
Keypad Door Mounting Kits
Door Mounting Kit for LA500 Internal Keypad
The removable keypad on LA500 can be mounted on a panel door using the parts below. When mounting the keypad externally a blind cover should be applied to the drive. Cables WV001-YEG or WV003-YEG are recommended as extension cable.
Part Door mounting kit for LA500 integrated Blind cover for LA500 keypad Model Number ZPBA-GA500 JVOP-KPBCH04AAA SAP# 10106938 10106937
Appearance
(Door mounting kit does not contain a keypad, blind cover or cable!)
Door Mounting Kits for LCD Keypads (with or without Bluetooth)
The LCD keypads can be mounted to a panel front door using one of the mounting kits below.
Type of Mounting Brackets have tapped holes for use with brackets have untapped holes for use with screws panel studs Model Number 900-192-933-001 900-192-933-002 SAP# 10090514 10090515
Appearance
18 YASKAWA Europe GmbH | LA500 Data Sheet
| Column | Door mounting kit for LA500 integrated | Column | Blind cover for LA500 | Column | Column |
|---|---|---|---|---|---|
| keypad | |||||
| ZPBA-GA500 | JVOP-KPBCH04AAA | ||||
| 10106938 | 10106937 |
| Column | Brackets have tapped holes for use with | Column | Column | brackets have untapped holes for use with | Column |
|---|---|---|---|---|---|
| screws | panel studs | ||||
| 900-192-933-001 | 900-192-933-002 | ||||
| 10090514 | 10090515 |
Source page
Page 20
Accessories
Heatsink External Mounting Kit
LA500 drives with IP20 can be mounted with the heatsink out the back of the panel or enclosure in order to have the main source of heat loss outside and so reduce panel volume or panel cooling. A rectangular cut out is required in the panel. Drives are fixed using an heatsink external mounting kit. Details on assembly and installation can be found the Installation Manual for these kits (TOEPC72060009_).
Important: • With this method of mounting the rated output current might require a derating. See section “Deratings“ in this document. • The backside of the drive remains IP20. The externally mounted heatsink should not be exposed to dusty or wet environment that would normally require a higher degree of ingress protection.
Appearance
Heatsink External Mounting Kit Model Numbers
Voltage Power kW LA500 Model Heatsink External Mounting Kit SAP# Class 3x400V 4 LA50x4009xxx ZPSA-GA50V3-1 10105756 3x400V 5.5 LA50x4015xxx ZPSA-GA50V5-1 10105758 3x400V 7.5 LA50x4018xxx ZPSA-GA50V5-1 10105758 3x400V 11 LA50x4024xxx ZPSA-GA50V6-1 10105759 3x400V 15 LA50x4031xxx ZPSA-GA50V6-1 10105759 3x400V 18.5 LA50x4039xxx ZPSA-GA50V8-1 10105761 3x400V 22 LA50x4044xxx ZPSA-GA50V8-1 10105761
LA500 Data Sheet | YASKAWA Europe GmbH 19
| LA500 Model | Column | Column | Heatsink External Mounting Kit | Column | Column | SAP# | Column | Column |
|---|---|---|---|---|---|---|---|---|
| LA50x4009xxx | ZPSA-GA50V3-1 | 10105756 | ||||||
| LA50x4015xxx | ZPSA-GA50V5-1 | 10105758 | ||||||
| LA50x4018xxx | ZPSA-GA50V5-1 | 10105758 | ||||||
| LA50x4024xxx | ZPSA-GA50V6-1 | 10105759 | ||||||
| LA50x4031xxx | ZPSA-GA50V6-1 | 10105759 | ||||||
| LA50x4039xxx | ZPSA-GA50V8-1 | 10105761 | ||||||
| LA50x4044xxx | ZPSA-GA50V8-1 | 10105761 |
Source page
Page 21
Accessories
Cable Shield Clamp Kit
A cable shield kit can be mounted at the bottom of the drive in order to easy cable shield connection and provide a strain relief at the same time.
Important: • Cable shield and UL Type 1 kits cannot be installed simultaneously.
Appearance
Cable Shield Kit Model Numbers Voltage Power kW LA500 Model Shield Clamp Kit SAP# Class (HD) 3x400V 4 LA50x4009xxx ZHZ-GA50V3 10108105 3x400V 5.5 LA50x4015xxx ZHZ-GA50V5 10108107 3x400V 7.5 LA50x4018xxx ZHZ-GA50V5 10108107 3x400V 11 LA50x4024xxx ZHZ-GA50V6 10108108 3x400V 15 LA50x4031xxx ZHZ-GA50V6 10108108 3x400V 18.5 LA50x4039xxx ZHZ-GA50V8 10108110 3x400V 22 LA50x4044xxx ZHZ-GA50V8 10108110
20 YASKAWA Europe GmbH | LA500 Data Sheet
| LA500 Model | Shield Clamp Kit | SAP# |
|---|---|---|
| LA50x4009xxx | ZHZ-GA50V3 | 10108105 |
| LA50x4015xxx | ZHZ-GA50V5 | 10108107 |
| LA50x4018xxx | ZHZ-GA50V5 | 10108107 |
| LA50x4024xxx | ZHZ-GA50V6 | 10108108 |
| LA50x4031xxx | ZHZ-GA50V6 | 10108108 |
| LA50x4039xxx | ZHZ-GA50V8 | 10108110 |
| LA50x4044xxx | ZHZ-GA50V8 | 10108110 |
Source page
Page 22
Power Options
Power Options
AC Input Reactors
Input reactors can be applied in order to reduce harmonic distortion on the AC input line. Reactors are offered as IP00 protection. IP20 covers are separately available. 200V Model
Reactor SAP# LA500 Model IP00 IP20 cover IP00 IP20 cover LA50C2018xx LR3 40-4/20 IP20-Box32 10011010 10062614 LA50C2025xx LR3 40-4/45 IP20-Box35 10011017 10062617 LA50C2033xx LA50C2047xx LR3 40-4/70 IP20-Box37 10011021 10062619 LA50C2060xx LA50C2075xx LR3 40-4/90 IP20-Box39 10011023 10062621 400V Model Reactor SAP# LA500 Model IP00 IP20 cover IP00 IP20 cover LA50C4009xxx B 1103136 IP20-Box32 10008858 10062614 LA50C4015xxx B 1103138 IP20-Box35 10000040 10062617 LA50C4018xxx LA50C4024xxx B 1103139 IP20-Box35 10000041 10062617 LA50C4031xxx B 1103140 IP20-Box37 10000042 10062619 LA50C4038xxx B 1103141 IP20-Box39 10008862 10062621 LA50C4045xxx B 1103142 IP20-Box39 10008863 10062621
LA500 Data Sheet | YASKAWA Europe GmbH 21
| Column | Reactor | Column | Column | Column | Column | Column | SAP# | Column | Column | Column | Column |
|---|---|---|---|---|---|---|---|---|---|---|---|
| IP00 | IP20 cover | IP00 | IP20 cover | ||||||||
| LR3 40-4/20 | IP20-Box32 | 10011010 | 10062614 | ||||||||
| LR3 40-4/45 | IP20-Box35 | 10011017 | 10062617 | ||||||||
| LR3 40-4/70 | IP20-Box37 | 10011021 | 10062619 | ||||||||
| LR3 40-4/90 | IP20-Box39 | 10011023 | 10062621 |
| Column | Reactor | Column | Column | Column | Column | Column | SAP# | Column | Column | Column | Column |
|---|---|---|---|---|---|---|---|---|---|---|---|
| IP00 | IP20 cover | IP00 | IP20 cover | ||||||||
| B 1103136 | IP20-Box32 | 10008858 | 10062614 | ||||||||
| B 1103138 | IP20-Box35 | 10000040 | 10062617 | ||||||||
| B 1103139 | IP20-Box35 | 10000041 | 10062617 | ||||||||
| B 1103140 | IP20-Box37 | 10000042 | 10062619 | ||||||||
| B 1103141 | IP20-Box39 | 10008862 | 10062621 | ||||||||
| B 1103142 | IP20-Box39 | 10008863 | 10062621 |
Source page
Page 23
Power Options
Braking Resistors
LA500 drives have embedded braking transistors. Resistors selected from the table below can be directly connected to terminals B1 and B2. When connecting with other resistors, the resistance must be higher than the minimum value listed below.
200V Model Minimum Resistor LA500 Model Resistor SAP# 40% ED (Ohm) LA50C2018xx RH-1560W040 32 10004350 LA50C2025xx RH-2700W025 9,6 10004351 LA50C2033xx RH-2700W025 9,6 10004351 LA50C2047xx RH-9600W015 9,6 10004358 LA50C2060xx RH-9600W015 9,6 10004358 LA50C2075xx RH-9600W015 9,6 10004358
400V Model
Minimum Resistor LA500 Model Resistor SAP# 40% ED (Ohm) LA50C4009xx RH-1000W120 100 10004349 LA50C4015xx RH-1560W040 32 10004350 LA50C4018xx RH-1560W040 32 10004350 LA50C4024xx RH-2700W025 20 10004351 LA50C4031xx RH-3700W025 20 10004352 LA50C4038xx RH-4800W022 19,2 10004353 LA50C4045xx RH-6000W022 19,2 10004356 • 40% ED : 120 s cycle time (t) and 48 s switch on time (ton) Rate of
22 YASKAWA Europe GmbH | LA500 Data Sheet
| Resistor 40% ED | Column | Column | Column | Minimum | Column | SAP# | Column | Column |
|---|---|---|---|---|---|---|---|---|
| Resistor | ||||||||
| (Ohm) | ||||||||
| RH-1560W040 | 32 | 10004350 | ||||||
| RH-2700W025 | 9,6 | 10004351 | ||||||
| RH-2700W025 | 9,6 | 10004351 | ||||||
| RH-9600W015 | 9,6 | 10004358 | ||||||
| RH-9600W015 | 9,6 | 10004358 | ||||||
| RH-9600W015 | 9,6 | 10004358 |
| Resistor |
|---|
| 40% ED |
| Resistor 40% ED | Column | Column | Column | Minimum | Column | SAP# | Column | Column |
|---|---|---|---|---|---|---|---|---|
| Resistor | ||||||||
| (Ohm) | ||||||||
| RH-1000W120 | 100 | 10004349 | ||||||
| RH-1560W040 | 32 | 10004350 | ||||||
| RH-1560W040 | 32 | 10004350 | ||||||
| RH-2700W025 | 20 | 10004351 | ||||||
| RH-3700W025 | 20 | 10004352 | ||||||
| RH-4800W022 | 19,2 | 10004353 | ||||||
| RH-6000W022 | 19,2 | 10004356 |
| Resistor |
|---|
| 40% ED |
Source page
Page 24
Tools and Software
Tools and Software
Tools Tool Description System Connection DriveWizard 10 PC Tool for parameter Windows USB-mini management/backup/diagnostics DriveWizard Mobile app for parameter Android • Bluetooth Mobile management/backup/diagnostics • USB-mini with USB on-the- go adapter
iPhone • Bluetooth
Connection Cables Model Number Description SAP# JZSP-CVS06-02-E USB-mini connection cable for PC 2.5m 300-100-888
LA500 Data Sheet | YASKAWA Europe GmbH 23
Source page
Page 25
LA500 Lift Inverter
THE NEW REFERENCE IN COMPACT LIFT DRIVE
Document: LA500 Data sheet_EN_v04 Published: April 10, 2026
Technical data
Highlighted specifications
| Specification | Value | Page |
|---|---|---|
| Type | Model CIPR- LA50C... | Power | Current | Model Code | SAP# | 7 |
| Model CIPR- LA50C... | LA500 Drive Heat Losses (with EMC filter) | 12 |
| Model CIPR- LA50C... | LA500 Drive Heat Losses | 12 |
| Model CIPR- LA50C... | LA500 Rated Output Current in Ampere | 13 |
| Side-b | mounting | 14 |
| LA500 Model | Heatsink External Mounting Kit | SAP# | 20 |
| LA500 Model | Shield Clamp Kit | SAP# | 21 |
| LA50x4009xxx | ZHZ-GA50V3 | 10108105 | 21 |
| LA50x4015xxx | ZHZ-GA50V5 | 10108107 | 21 |
| LA50x4018xxx | ZHZ-GA50V5 | 10108107 | 21 |
| LA50x4024xxx | ZHZ-GA50V6 | 10108108 | 21 |
| LA50x4031xxx | ZHZ-GA50V6 | 10108108 | 21 |
| LA50x4039xxx | ZHZ-GA50V8 | 10108110 | 21 |
| LA50x4044xxx | ZHZ-GA50V8 | 10108110 | 21 |
| LR3 40-4/45 | IP20-Box35 | 10011017 | 10062617 | 22 |
| LR3 40-4/70 | IP20-Box37 | 10011021 | 10062619 | 22 |
| Resistor 40% ED | Minimum | SAP# | 23 |
Related products
Products covered by this document
- LA50C2018ABBProduct page
- LA50C2018EBBProduct page
- LA50C2025ABBProduct page
- LA50C2025EBBProduct page
- LA50C2033ABBProduct page
- LA50C2033EBBProduct page
- LA50C2047ABBProduct page
- LA50C2047EBBProduct page
- LA50C2060ABBProduct page
- LA50C2060EBBProduct page
- LA50C2075ABBProduct page
- LA50C2075EBBProduct page
- LA50C4009ABBProduct page
- LA50C4009EBBProduct page
- LA50C4015ABBProduct page
- LA50C4015EBBProduct page
- LA50C4018ABBProduct page
- LA50C4018EBBProduct page
- LA50C4024ABBProduct page
- LA50C4024EBBProduct page
- LA50C4031ABBProduct page
- LA50C4031EBBProduct page
- LA50C4039ABBProduct page
- LA50C4039EBBProduct page
- LA50C4045ABBProduct page
- LA50C4045EBBProduct page