WBD-602 User manual
Technical reference for WBD-602 User manual with 4 pages, 1 tables, searchable navigation and precise source-page references.
- Chapters
- 1
- Pages
- 4
- Language
- English
- Format

Complete web edition
The complete manual in one reading flow
Pages follow the exact source order. Searchable text is also available for every page.
Complete document
Pages 1 to 4
Source page
Page 1
(EN)
WBD-602
User Manual
Dinacell Electrónica SS..LL..
Source page
Page 2
30.5
85.5 17.5
58 4.5 O
(x)
20VDC 28VDC 48VAC/VDC
3A 1 57 5.82 Main device data 1.1 Components and dimensions (mm) LED's Status Description On (GREEN) Device with power. Off Device with no power. On (GREEN) All connected and programmed belts have continuity. Off One or more belts are broken and have no continuity. On (GREEN) Belt programmed, ON, and with continuity. On (RED) Belt programmed, ON, without continuity or broken. Off Programmed belt Off . 1.2 Electrical specifi cations Min. Power supply Max Max. voltage Contact Relay Max. current Number Output B1 to B6 short-circuitable to positive or to negative. 2
Source page
Page 3
Step-by-step installation
Read before installing: The broken belt detection system is composed 1 : 1 2 : 1 of a WBD-602 device and a series of connectors that are installed on the remaining ends of the elevators belts. For each belt of the elevator there must be two diff erent types of connectors, to diff erentiate them, the one that has a connection or cable output we will call connector-A. The one that does not have E-1 E-2 E-2 outputs,connector-B. Connector-A will go at one end of the belt along with the WBD-602 E-1 and Connector-B at the opposite end. In order to save cable it is advisable to place connectors-A and the WBD-602 device at the end of the belt closest to the elevators controller. In the diagram below we will call this end E-1 and the opposite, E-2. 1
Fig.2 Fig.3
The fi rst step is to fi x the device. As shown in FIGURE-1 it is possible to fi x it by means of a regular fl ange. It can also be fi xed to a solid part of the elevator with screws as shown in FIGURE-2.
2 Programming the number of belts: By lifting the devices cover, you should look for the microswitch shown in the displayed
fi gure. This microswitch has six tabs (as many as belts) with two On and Off positions. The belts that are connected to the device must be positioned as On and the remaining Off . On An example, in case of having two tapes connected to the device, tab 1 and 2 will have to be position as On and the remaining Off .
| Column | Fig.3 |
|---|---|
| The fi rst step is to fi x the device. As shown in FIGURE-1 it is possible to fi x it by means of a regular fl ange. It can also be fi xed to a solid part of the elevator with screws as shown in FIGURE-2. |
Source page
Page 4
Cabin Controller
Connections: By lifting the devices cover, you must make the connections in the following order: - The fi rst step is to connect Connectors-A to the WBD-602 device, as shown in the connection scheme, following the order B1,B2,B3.... B6. A-connectors have no polarity. - The second step is to connect the alarm relay to the control panel. You should note that the relay contact is normally closed when the system is OK and in case power is lost or a broken wire is detected the relay contact will open. - The third step is to connect the 24VDC power supply to the device. - To fi nish the installation check that the LEDs are turned on correctly (section 1.1).
Document Ref: D2071-02 Publication Date: 29/11/2024
Dinacell Electrónica S.L. Pol. Ind. Santa Ana C/ El Torno No8 CP 28522 Rivas Vaciamadrid, Madrid, ESPAÑA Tel. (+34) 913 001 435 Fax. (+34) 913 001 645 dinacell@dinacell.com www.dinacell.com
Document editions