Page 1
(EN)
SVS-R
Installation Manual
Dinacell Electrónica S.L.
Source page
Page 2
Introduction
We have developed a solution to be able to measure the load level in silos using our SVS-R sensor. Its installation is based on the adhesion of these sensors to the supports or legs of the silo detecting the micro deformations that occur in the structure generated by the load.
1.1 Contents of the bag
4x 4x 8x
Sensor SVS-R Allen M8x20 screws M8 nuts Flat washers
1.2 Necessary tools for the installation
Drill Ø 9 metal drill Ø 14 metal drill Screw accessories for drills
Fixed wrench Magnetic Allen Large fl anges Cutting pliers wrench 6mm.
1.2 Recommended tools for the installation
Torque wrench for 40Nm
Source page
Page 3
Step by step installation
SVS sensors are installed on one of the legs that support the weight of the silo. It should be placed in a clear area, which does not coincide with crossheads or crossbars. In case the silo is exposed to the direct sun, locate the sensor on the most protected leg.
2 3
Ø 9
4 5
Ø 14
6 7
40Nm
Ø 9
Source page
Page 4
8 9
Ø 14
10 11
Ø 9
40Nm
12 13
40Nm
14
+ Exc. Red + Signal Green SVS sensors are installed on one of the legs - Exc. Black that support the weight of the silo. It should be placed in a clear area, which does not coincide - Signal White with crossheads or crossbars. In case the silo is exposed to the direct sun, locate the sensor on Shield (GND) the most protected leg.
For more information www.dinacell.com
Document Ref: D2009-02 Publication Date: 14/11/2024