PFC
User Manual
PFC-300 PFC-500 PFC-1000 PFC-3500
Dinacell Electrónica S.L.
Source page
Page 2
1 Introduction
1.1 Description
PFC load cells are a weighing sensor located at the fi xed point of cables on
traction elevators load. In dinacell we have developed diff erent models of PFC sensors to be able to adapt them to the diff erent types of installations.
PFC sensors are plugged in & play load cells. This type of load cell is adjusted with a factory CELL value. This allows for easy adjustment with our load-weighing controls, without the need to insert a known weight into the elevator cabin. For more information refer to the load weighing control manual.
Calibrated sensor CELL value Model PFC-300 PFC-500 PFC-1000 PFC-3500 CELL value 300 500 1000 3500
1.2 Dimensions in mm depending on the model
Max Model ØA B ØC Max PFC-300 40 36 28 M-12 ±5°
PFC-500 48 40 35 M-16 PFC-1000 65 46 54 M-24 PFC-3500 70 62 57 M-30
ØC
2 B 1.1 Description PFC load cells are a weighing sensor located at the fi xed point of cables on traction elevators load. In dinacell we have developed diff erent models of PFC sensors to be able to adapt them to the diff erent types of installations. PFC sensors are plugged in & play load cells. This type of load cell is adjusted with a factory Plug && CELL value. Play Factory adjusted Ø A
| 40 | 36 | 28 |
|---|---|---|
| 48 | 40 | 35 |
| 65 | 46 | 54 |
| 70 | 62 | 57 |
Source page
Page 3
2 Step by Step installation
2.1 Place and way of installation
These load cells must be installed at the fi xed point of the elevator. Below you will fi nd an installation scheme sensors for the diff erent types of suspensions.
Rope Washer (s) Rope Springs terminal PFC sensor Plate Plate PFC sensor Rope terminal Springs Washer (s) Rope
1:1 Suspension Multiple suspension
2.2 Minimum distance between sensor
For installations where the minimum FIGURE 1 FIGURE 2 Min. distance between load Min. distance between load cells for distance is less than dimension A, it is cells for installation installation with SPACERS necessary to install SPACERS such as B B those shown in FIGURE 2. A
Model. (A) (B) Ref. SPACERS PFC-300 42 32 021891 A B PFC-500 50 38.5 021892 PFC-1000 67 51.5 021893 PFC-3500 72 58 021894 Ø25
2.3 Connecting cells to the device
Lastly, you must connect the cells USB cable to the load weighing control. To do this, you must take into account the steps indicated in the load weighing control manual to know when to make the connection. If you connect multiple PFC sensors to a load weighing control with only a 5 wire input, you must use an INTERFACE. 3 A For installations where the minimum distance is less than dimension A, it is necessary to install SPACERS such as those shown in FIGURE 2. A A
| 42 | 32 |
|---|---|
| 50 | 38.5 |
| 67 | 51.5 |
| 72 | 58 |
Source page
Page 4
Dinacell Electronica S.L. The information contained by the document is subject to change without notice. The content indicated herein should be used as an overview of the product. It should not be construed as a guarantee of quality or durability. Dinacell Electronic shall not be liable for technical or editing errors or omissions contained in this document.