DinacellData sheet

PFC Data sheet

Technical reference for PFC Data sheet with 3 pages, 5 tables, searchable navigation and precise source-page references.

Chapters
1
Pages
3
Language
English
Format
PDF
PFC Data sheet
First page of the technical document

Complete web edition

The complete manual in one reading flow

Pages follow the exact source order. Searchable text is also available for every page.

1

Complete document

Pages 1 to 3

Source page

Page 1

Open in PDF

www.dinacell.com

PFC

Sensor designed for the

terminals fi xed point

Plug &

Play Factory adjusted More information

PFC Compression load cell

The PFC load cells are a weighing solution at the fi xed point of cables in traction elevators.

The advantages of the new design of the PFC sensor are as follows: - This sensor has a low profi le that improves weighing accuracy. - A new geometric design, for perfect stability when weighing at all angles. - Space saving and a lower height sensor. - No need to add washers to the installation. - Aff ordable with a competitive price. - Plug & play load cells (adjusted with a factory CELL). This allows for easy adjustment, without the need to enter a known weight, when using our measuring devices.

For a complete installation

These sensors are installed at the fi xed point and feature a USB cable output. In order to have an independent reading of the weight of each cable, we recommend the use of our OMEGA device.

For installations that need to connect a set of sensors to a load limiter, with a single input, it is necessary to combine the signal in a single output by using a (1) INTERFACE. These accessories off er cable output without connector or WITH USB (depending on the type of input of the limiting device).

111... INTERFACE

1/3

Source page

Page 2

Open in PDF

PFC

D max

±5°

ØC

ØA B Datasheet Specifications Parameter Units Specifications Model - PFC-300 PFC-500 PFC-1000 PFC-3500 Nominal Load (N.L.) kg 300 500 1000 3500 Nominal Sensibility (N.S.) mV/V 2.0±0.01 Accuracy - 1% Zero balance mV/V ±0.02 Maximum excitation voltage V 12 Compensated -10 ... +40 (+14 ... +104) Temperature range Operating oC (oF) -20 ... +60 (-4 ... +140) Storage -20 ... +70 (-4 ... +158) Min. Insulation resistance (V.Test = 100V) GΩ >4 Input resistance Ω 350 ... 450 Output resistance Ω 350 Without characteristics loss 150 Load limit %N.L. Breaking >500 Type - 4 x 0.14mm2 Ø4.3 Termination - USB Cable Standard length m 2 Material - Polyurethane (PU) Material - Alloy steel Sensor Surface treatment - Chemical nikel Protection class - IP50 Dimensional drawings (mm) and wiring diagram + Exc. + Signal - Exc. - Signal Shield (GND) Model ØA B ØC D max PFC-300 40 36 28 M-12 PFC-500 48 40 35 M-16 PFC-1000 65 46 54 M-24 PFC-3500 70 62 57 M-30 2/3

-PFC-300PFC-500PFC-1000
kg3005001000
mV/V
-
mV/V
V
oC (oF)
Ω
Ω
%N.L.
-
-
m
-
-
-
-
403628
484035
654654
706257

Source page

Page 3

Open in PDF

PFC

www.dinacell.com

Dinacell Electrónica S.L. Pol. Ind. Santa Ana, C/ de la Fundición 8 CP 28522 Rivas Vaciamadrid, Madrid, ESPAÑA Tel. (+34) 913 001 435 15/04/2026 5.32 24 B B A A A 4 16.2 A B C A Datasheet Product Reference Ref. Model 021380 PFC-300 021381 PFC-500 021382 PFC-1000 021383 PFC-3500 FIGURE 1 FIGURE 2 Min. distance Min. distance between load cells for between load cells Accessory: SPACERS installation for installation with SPACERS For installations where the minimum distance is less than dimension A, it is necessary to install SPACERS such as those shown in FIGURE 2. A B Model A B Ref. SPACERS PFC-300 42 32 021891 PFC-500 50 38.5 021892 PFC-1000 67 51.5 021893 Ø25 PFC-3500 72 58 021894 Accessory: INTERFACE Parameter Units Specifi cations Model - INTERFACE Temperature range oC (oF) -20 ... +60 (-4 ... +140) Casing material - Fireproof V0 Protection class - IP50 Cable type - 4 x 0.22mm2 Ø4 Standard length m 5 + Ferrita Dimensions in mm USB Input - 6 12 USB A B C Wiring Wiring Cable Output - USB USB connection connection 6 48 69 74 Ref. - 007555 007274 007554 007275 12 84 105 110 For more information Certifi ed company Document Ref: D1859-07 Publication Date: VMFT06.04 Dinacell Electrónica S.L. reserves the right to add, modify and/or delete content of the document without prior notice. The content indicated here should be used as general product information. It should not be interpreted as a guarantee of quality or durability. 3/3

4232
5038.5
6751.5
7258
-ColumnColumnColumn
oC (oF)
-
-
-
m
-6
-USBWiring connectionUSB
-007555007274007554
AB
4869
84105