DinacellUser manual

PF User manual

Technical reference for PF User manual with 4 pages, 1 tables, searchable navigation and precise source-page references.

Chapters
1
Pages
4
Language
English
Format
PDF
PF User manual
First page of the technical document

Complete web edition

The complete manual in one reading flow

Pages follow the exact source order. Searchable text is also available for every page.

1

Complete document

Pages 1 to 4

Source page

Page 1

Open in PDF

(EN)

PF

User Manual

PF-300 PF-500 PF-1000

Dinacell Electrónica S.L.

Source page

Page 2

Open in PDF

1 Introduction

1.1 Description

PF load cells are a weighing sensor located at the fi xed point of cables on traction elevators load. In dinacell we have developed diff erent models of PFC sensors to be able to adapt them to the diff erent types of installations

PF sensors are plugged in & play load cells. This type of load cell is adjusted with a factory CELL value.

This allows for easy adjustment with our load-weighing controls, without the need to insert a known weight into the elevator cabin. For more information refer to the load weighing control manual.

Calibrated sensor CELL value

Model CELL value 600 1000 2000

1.2 Dimensions in mm depending on the model

Model

Wiring diagram

+ Exc. (Red) + Signal (Green) - Exc. (Black)

- Signal (White) Shield (GND)

2 B 1.1 Description PF load cells are a weighing sensor located at the fi xed point of cables on traction elevators load. In dinacell we have developed diff erent models of PFC sensors to be able to adapt them to the diff erent types of installations PF sensors are plugged in & play load cells. This type of load cell is adjusted with a factory CELL value. This allows for easy adjustment with our load-weighing controls, without the need Plug & Play Factory adjusted PF-300 PF-500 PF-1000 ØA ØC ±5° ØA B ØC ØD E PF-300 42 42 12.5 20 30 Ø8.4 ØD PF-500 47 45 16.5 20 32 E PF-1000 54 50.5 25 30 39 ØA E

424212.520
474516.520
5450.52530

Source page

Page 3

Open in PDF

Installation step-by-step

These load cells must be installed at the fixed point of the elevator. Below you will fin an installation scheme sensors for the different types of suspensions.

Rope Washer (s)

Plate Plate

Rope Washer (s)

Lastly, you must connect the cells USB to the load weighing control. To do this, you must take into

account the steps indicated in the load weighing control manual to know when to make the connection. If you connect multiple PF sensors to a load weighing control with only one input, you must use an INTERFACE. 3 A 2 2.1 Place and way of installation Rope Springs terminal Sensor PF Sensor PF Rope terminal Springs 1:1 Suspension Multiple suspension 2.2 Minimum distance between sensor FIGURE 1 Model (A) Min. distance between load cells for installation PF-300 44 PF-500 49 PF-1000 56 A A 2.3 Connecting cells to the device A A

Source page

Page 4

Open in PDF

Dinacell Electronica S.L. The information contained by the document is subject to change without notice. The content indicated herein should be used as an overview of the product. It should not be construed as a guarantee of quality or durability. Dinacell Electronic shall not be liable for technical or editing errors or omissions contained in this document.

Document Ref.: D2288-01

Publication date: 01/07/2024