PF

Sensor designed for the

terminals fifi xed point

More information

PF Compression load cell

The PF compression sensors are aaa weighing solution located at the rope terminal fififi x---point of the traction elevators... These sensors are installed on each of the terminal fififi xed point receiving the weight individually from each rope.

It works in a compression load way of measurement, on which it provides the system with great reliability and mechanical robustness. With a compact design and occupying a minimal space, these sensors could support up to a thousand kilograms.

For a complete installation

These sensors are installed at the terminal fififi xed point and have aaa USB cable output... In order to have an independent weight reading on each cable,,, we recommend using our OMEGA control unit... For installations that need to connect aaa set of sensors to a load limiter, with one single input:

PF sensors assemblies can be formed by joining these sensors to a (1) INTERFACE. The INTERFACE off er cable output without aaa wiring connection (((555wires))) or with USB (depending on the type of input of the controllers).

(((111))) INTERFACE

1/3

Source page

Page 2

Open in PDF

PF

ØA ØC ±5°

Ø8.4 ØD E

ØA

E B Datasheet Specifications Parameter Units Specifications Model - PF-300 PF-500 PF-1000 Nominal Load (N.L.) kg 300 500 1000 Accuracy - 0.1% Zero balance mV/V ±0.02 Maximum excitation voltage V 12 Compensated -10 ... +40 (+14 ... +104) Temperature range Operating oC (oF) -20 ... +60 (-4 ... +140) Storage -20 ... +70 (-4 ... +158) Min. Insulation resistance (V.Test = 100V) GΩ 4 Input resistance Ω 350 ... 400 Output resistance Ω 350±3 Safe 150 Load limit %N.L. Without characteristics loss 300 Type - 4 x 0.14mm2 Ø4.3 Termination - USB Cable Standard length m 2 Material - Polyurethane (PU) Material - Aluminum Sensor Surface treatment - Anodized Protection class - IP50 Dimensional Drawings (mm) Model ØA B C ØD E PF-300 42 42 12.5 20 30 PF-500 47 45 16.5 20 32 PF-1000 54 50.5 25 30 39 2/3

-PF-300PF-500
kg300500
-
mV/V
V
oC (oF)
Ω
Ω
%N.L.
-
-
m
-
-
-
-
424212.520
474516.520
5450.52530

Source page

Page 3

Open in PDF

www.dinacell.com

Dinacell Electrónica S.L. Pol. Ind. Santa Ana, C/ de la Fundición 8 CP 28522 Rivas Vaciamadrid, Madrid, ESPAÑA Tel. (+34) 913 001 435 08/04/2026 5.32 24 Datasheet PF Product Reference Ref. Model 013962 PF-300 013332 PF-500 014058 PF-1000 Accessory::: INTERFACE 4 Parameter Units Specifi cations Model - INTERFACE 16.2 A Temperature range oC (oF) -20 ... +60 (-4 ... +140) B Casing material - Fireproof V0 C Protection class - IP50 Cable type - 4 x 0.22mm2 Ø4 Standard length m 5 + Ferrita Dimensions in mm USB Input - 6 12 USB A B C Wiring Wiring Cable Output - USB USB connection connection 6 48 69 74 Ref. - 007555 007274 007554 007275 12 84 105 110 For more information Certifi ed company Document Ref: D1046-05 Publication Date: VMFT06.04 Dinacell Electrónica S.L. reserves the right to add, modify and/or delete content of the document without prior notice. The content indicated here should be used as general product information. It should not be interpreted as a guarantee of quality or durability. 3/3

-ColumnColumnColumn
oC (oF)
-
-
-
m
-6
-USBWiring connectionUSB
-007555007274007554
AB
4869
84105