Cable Load Limiters

LMK

INSTRUCTIONS MANUAL

Source page

Page 2

Open in PDF

LMK

Index

1.- Introduction 3

2.- Dimensions, Electrical Characteristics 3

3.- Connection and colours code 3

4.- Control Outputs (Alarms). 4

5.- Access to menu parameters 4

6.- Modification of parameters 5

Modification of an alarm. 5

Modification of a parameter (no alarm) 5

7.- Programming structure 5

8.- Unit control adjustment 6

Setting of zero 6

Adjustment of sensibility with a well known weight 6

9.- Errors presentation. 6

10.-Quick programming guide 7

Source page

Page 3

Open in PDF

LMK

1. Introduction

LM_K load limiter is the result of the evolution of industrial weighing systems designed to limit load, and based in the measurement with strain gages.

The main field of application is lifting devices, where load limitation is needed, offering measurement accuracy higher than usually required.

The function of this device is to measure the load and notify thought the relays if this load exceed the established levels. These levels have to be programmed to the alarm relays which act on the control panel.

2. Dimensions, Electrical Characteristics

Electrical characteristics

Nominal Tension:......................... 24 - 48Vdc

Maximum current less than:........ <100mA. 2 Relays:

1Open contact potential free. 5 Amperes 30VDC

5 Amperes 250 VAC

3. Connection and colours code

Positive supply Red (+) 24-48Vdc Black Negative supply Volt-free contact. Relay 1 Yellow-Blue (AL 1) Volt-free contact. Relay 2 White-Green (AL 2) Shield Ground (GND)

Cable Model nL (t) A B C D E ØF Length LMPK 1, 2, 3.5 y 7 188 28 26 140 M6 7 ... 28 4m. LMGK 15 y 20 322 32 36 260 M8 19 ... 32

ModelnL (t)ABCDEØFColumnCableColumn
Length
LMPK1, 2, 3.5 y 71882826140M67 ... 28
LMGK15 y 203223236260M819 ... 32

Source page

Page 4

Open in PDF

LMK

4. Control Outputs (Alarms)

LMxK limiter has 2 relays that change the status depending on the programmed parameters.

We can program the next parameters for the alarms:  (AL-1, AL-2) Alarm trigger level, when the load crosses this level the alarm is activated.  The resting status of the relays: that means the relay status when the load does not reach the trigger alarm level.

o ON Relay active, closed contact. o OFF Relay inactive, open contact .

 The time-delay in tenths of a second. The default value is 0000, but it is usual to use it when lift load is near of the crane limit (Example: 0030 = 3 seconds). Operation:

When the load exceeds the alarm threshold level, a timer starts counting time, and when it reaches the delay time (tiE) the alarm is activated (change the relay status).  The alarm is not activated if the level of load decrease below the trigger alarm level before the timer reaches the delay time.  If the average of load exceeds 120% of the trigger level, the alarm will be activated immediately, ignoring the delay time.  If the load exceeds 140% of the trigger level, the alarm will be activated immediately (about 30msg).

 If the delay time is zero, the relay will be activated immediately when the load exceeded the threshold level. Note: Alarms can be configured with negative values, making easier the detection of "SLACK CABLE".

The relays have a normally open volt-free contact. It is important to note that if power turn off, the relay contact opens.

5. Acceso Access to menu parameters

Pressing this key successively all the programmable parameters are shown in cycle way. To go back to the weight presentation, press the key until the end of the menus, or press it during 3 seconds.

Once there is a parameter selected, press this key to modify the value

If this key is kept pressed when there is a parameter selected, the display shows the value of that parameter.

Source page

Page 5

Open in PDF

LMK

6. Modification of parameters

Modification of an alarm

1. Press successively key until select the wished alarm.

2. Press Key to enter in parameter modification. The left digit blinks..

3. Select the wished value in the display using keys & .

4. Press Key to introduce the chosen value .

5. Change the relay status with key .

6. Press twice to save the change. If it is pressed once, after 10 seconds the process finishes without saving the changes.

Modification of a parameter (no alarm)

1. Press successively key until select the wished parameter.

2. Press key to enter in parameter modification. The left digit blinks.

3. Select the wished value in the display using keys & .

4. Press twice to save the change. If it is pressed once, after 10 seconds the process finishes without saving the changes, and the display shows again the parameter.

7. Programming structure

Pressing successively the key the menu parameters are shown in the following order.

Equipo en modo de Pesaje Device in weighing mode

Alarm level 1 and status relay 1 (Led indicator AL-C)

Alarm level 2 and status relay 2 (Led indicator AL-S)

Adjustment on zero

Adjustment of sensibility with a well known weight

Adjustment of sensibility with the nominal load of the cell

Adjustment of alarm timer

Source page

Page 6

Open in PDF

LMK

8. Unit control adjustment

This chapter is necessary for the unit to know the relation between the signal from the cell (output) and the weight supported by the crane or hook. The adjustment is made in 2 steps as follows:

1. Setting of zero

2. Adjust of sensibility .

Setting of zero:

1. Select menu option .

2. Check that the hook is empty and press key . The display will blink 3. Press key while the display is blinking to confirm the operation that starts with a countdown. At

the end the display will show parameter .

Note: If not pressed before the end of intermission, the operation is not stored, and the display shows the parameter .

Adjustment of sensibility with a well known weight:

1. Hang on the hook a well known weight (it is recommended a minimum weight of 50% of the LMK nominal load). 2. Select menu option , and press to enter in modification.

3. Input the value of the well known weight with the keys .

4. Press twice (The unit starts a countdown and the value remains saved). Then the display will show the next adjusting parameter .

Note: If not pressed before the end of intermission, the operation is not stored, and the display shows

the parameter again. .

9. Errors presentation

Error Descripción Action

Negative overflow of the converter, so the load cell is giving Return to factory a negative signal too high. Positive overflow. Load cell is supporting a higher weight It is necessary to use a load cell than the nominal load. with higher nominal load. Polarity error. It is detected when the control unit is adjusted with a well known weight and the polarity is changed, or the Adjust again on zero and weight. weight is not in the hook during the adjustment.

Data loss in memory. Program again.

Load cell with very low sensibility. Usually the unit is wrong Adjust again on zero and weight. adjusted. Note: When an error occur all the relays are open and (RELAY = OFF).

Source page

Page 7

Open in PDF

LMK

10. Quick programming guide

1. Adjust alarm with the load level value that activates the alarm 1 ,selecting the resting status relay (ON= Active relay ,closed contact)

2. Adjust alarm with the load level value that activates the alarm 2, selecting the resting state relay (ON= Active relay ,closed contact) 3. Place the hook one meter above the floor.

4. Adjust the with the crane free of weight .

5. Place a well known weight in the hook (minimum 50% of the LMxK nominal load).

6. Adjust the Input the value of the well known weight.

7. Adjust the alarm timer

Remark: It is important to adjust on zero before the weight adjustment.

Source page

Page 8

Open in PDF

LMK

Dinacell Electrónica sl. tiene todos los derechos reservados. Según las leyes de propiedad intelectual, queda prohibida la copia, reproducción, adaptación, alteración o modificación, total o parcial, de los contenidos, salvo para uso exclusivo y privado del usuario o bajo expresa autorización de Dinacell Electrónica sl.; no responsabilizandose de los posibles errores de impresión o copia. Dinacell Electrónica sl. Pol. Ind. Santa Ana C / Torno No 8 - 28522 - Rivas Vaciamadrid - Madrid Tel.: +34 91 300 14 35 - Fax.: +34 91 300 1645 - www.dinacell.com D 1 1 8 2 / 8 1 9 0 - / 0 1 0 9 8

Technical data

Highlighted specifications

SpecificationValuePage
ModelnL (t) | A | B | C | D | E | ØF | Cable3
LMPK1, 2, 3.5 y 7 | 188 | 28 | 26 | 140 | M6 | 7 ... 283
LMGK15 y 20 | 322 | 32 | 36 | 260 | M8 | 19 ... 323