DinacellData sheet

CTG Data sheet

Technical reference for CTG Data sheet with 3 pages, 3 tables, searchable navigation and precise source-page references.

Chapters
1
Pages
3
Language
English
Format
PDF
CTG Data sheet
First page of the technical document

Complete web edition

The complete manual in one reading flow

Pages follow the exact source order. Searchable text is also available for every page.

1

Complete document

Pages 1 to 3

Source page

Page 1

Open in PDF

www.dinacell.com

CTG

Load cell for weighing loads on

large hooks

More information

CTG Traction weighing cell

The CTG load cell is applicable in any industrial process,,, for load limitation on large hooks... Its diff erent nominal loads range from 333...222 to 555000 tonnes... This cell is made of aaa double---shearing sensor,,, to achieve greater design resistance.

The main use of this cell is focused on the crane sector. Its design integrates two holes for the fi xing of electronic weighing equipment. Its specifi c characteristics make this cell an optimal solution for industrial environments with a IP67 protection.

1/3

Source page

Page 2

Open in PDF

CTG

G H

D A C = = = = Datasheet Specifications Parameter Units Specifications Model - CTG Nominal Load (N.L.) t 3.2 / 6.3 12 / 16 / 25 / 35 / 40 / 50 Nominal Sensibility (N.S.) mV/V 1.4 ... 2.0 Zero balance %N.S. 2 Maximum excitation voltage V 12 24 Number of intervals (n) - 3000 Hysteresis error %N.S. 0.033 Crepp, over 30 minutes %N.S. 0.03 Maximum linearity error %N.S. 0.022 Compensated -10 ... +40 (+14 ... +104) Temperature range Operating oC (oF) -20 ... +60 (-4 ... +140) Storage -30 ... +70 (-22 ... +158) Temperature effect on sensibility %N.S. ± 0.022 Min. Insulation resistance (V.Test = 100V) GΩ 4 Simple Shearing (S.S) 380 ± 10 - Input resistance Ω Double Shearing (D.S) - 760 ± 20 Simple Shearing (S.S) 350 ± 2 - Output resistance Ω Double Shearing (D.S) - 700 ± 4 Without characteristics loss 150 Load limit %N.L. Breaking 300 Type - 4 x 0.22 mm2 Ø6 Cable Standard length m 1.5 Material - Polyurethane (PU) Material - Alloy steel Sensor Surface treatment - Chemical nikel Protection class - IP67 Working on - Traction Dimensional drawings (mm) and wiring diagram = ØE + Exc. Red + Signal Green - Exc. Black - Signal White = Shield (GND) ØF N.L. (t) 3.2 6.3 12 16 25 35 40 50 Type - - C L C L C L C L C L - A 250 270 285 320 300 360 360 400 400 440 438 512 512 B 80 100 100 100 100 100 110 110 130 130 160 160 160 ØE C 26 36 49 49 57.5 57.5 68 68 68 68 90 90 90 D 199.5 210 205 242.5 209 269 240 280 270 310 275 350 350 ØE 21.5 27 35.5 35.5 43 43 53 53 59 59 72 72 72 ØF - 6.25 6.25 6.25 6.25 6.25 8.5 8.5 12.5 12.5 16.5 16.5 16.5 G - 60 60 60 60 60 60 60 100 100 100 100 100 H 70 80 100 100 115 115 130 140 162 155 171 191 191 2/3

-Column
t3.2 / 6.3
mV/V
%N.S.
V12
-
%N.S.
%N.S.
%N.S.
oC (oF)
%N.S.
Ω380 ± 10
-
Ω350 ± 2
-
%N.L.
-
m
-
-
-
-
-
--CLCLCLCLCL
250270285320300360360400400440438512
80100100100100100110110130130160160
2636494957.557.5686868689090
199.5210205242.5209269240280270310275350
21.52735.535.54343535359597272
-6.256.256.256.256.258.58.512.512.516.516.5
-60606060606060100100100100
7080100100115115130140162155171191

Source page

Page 3

Open in PDF

Datasheet CTG

Product Reference

Ref. Type Nominal Load (t) Model 001669 - 3.2 001670 - 6.3 002578 C 12 001336 L 001327 C 16 001326 L 002090 C CTG 25 002332 L 002224 C 35 002922 L 004028 C 40 006450 L 004461 - 50

For more information

www.dinacell.com Certifi ed company Dinacell Electrónica S.L. Pol. Ind. Santa Ana, C/ de la Fundición 8 CP 28522 Rivas Vaciamadrid, Madrid, ESPAÑA Tel. (+34) 913 001 435 Document Ref: D1123-02 Publication Date: 27/07/2026 VMFT06.04

Dinacell Electrónica S.L. reserves the right to add, modify and/or delete content of the document without prior notice. The content indicated here should be used as general product information. It should not be interpreted as a guarantee of quality or durability. 3/3

-3.2
-6.3
C12
L
C16
L
C25
L
C35
L
C40
L
-50

Related products