(EN)
CNS
User Manual
Dinacell Electrónica S.L.
Source page
Page 2
Dinacell Electrónica S.L. Product Notice The contained information in this document is This manual describes the features that subject to changes without previous notice. serve the product in its most up-to-date The content shown here should be used as version. The resources included in this general product information. It should not manual serve the CNS model. be interpreted as a guarantee of quality or durability. Notice about the battery and its consumption Electronic Dinacell shall not be liable for The battery consumption values given technical or editing errors or omissions here are for informational purposes only. contained in this document. They also depend on the actual conditions of use and are no guarantee of future performance. Subject to change.
Document Ref.: D1954-04
Publication date: 04/03/2024
Firmware version: 1.00
For more information www.dinacell.com
Source page
Page 3
INDEX
1 Introduct i o n ......................................................................................... 5 1.1 Product description ................................................................ 5 1.2 Dimensions and components of the device .......................... 5
2 Programing, functions, and device status. .................................... 5
2.1 Power selection and transmission time ................................ 5 2.2 Functions of the buttons .......................................................... 6 2.3 Device status and errors ........................................................... 6
3 Step by step installation guide ........................................................ 7
3.1 Device Installation .................................................................. 7 3.2 System adjustme n t .................................................................... 7
Source page
Page 4
1 Introduction
1.1 Product description
The CNS device is designed to send data through wireless connectivity without the need for WiFi or SIM card. The combination of this device with the SilosApp application will allow you monitor your installations remotely.
1.2 Dimensions and components of the device
Components (1) Device keyboard. The functionalities are indicated in section 2.2. (2) Device transmission antenna (3) Battery connector.
information, see section 2.1. (7) Antenna connector. (8) Sensor connector. (9) Sensor input with gland.
4 4 DEF0123 C 2 3 BA98765 6 7 4 5 9 .cxE + .cxE - langiS + langiS - )DNG( dleihS Dineleactcróeniclal 8 ModelCNS 911 151 631 Ø8,5 R2,3 Ø5 40 6.5 66 62
| Column | Dineleactcróeniclal ModelCNS |
|---|---|
| 40 66 |
Source page
Page 5
2 Programing, functions, and device status.
2.1 Power selection and transmission time
234 There is a selector on the device which allows the user to adjust the power and transmission 1 time in order to establish different operating modes. The power must always be according to the coverage of the installation area. The lower the coverage, the greater the power. Some transmission times have auto mode. This feature allows the device to wake up every 20 minutes and update the weight automatically in case of detecting large load variations in the silo.
Estimation in years of Modes Power Transmission time AUTO mode battery life
C/D/E/F modes are reserved for future uses.
There are some shipping times that have the AUTO mode. This function allows the team to monitor the weight every 20 min and make an automatic shipment, in case of detecting significant load variations in the silo.
Approximately halfway through the configured sending time, the equipment saves a weight that will be output along with the current weight.
5 0 FEDCBA9 8 56 7 0 4h >10 1 2h 8 100% 2 1h 4 3 30min 2 4 4h >10 5 2h 9 80% 6 1h 5 7 30min 3 8 4h >10 9 2h 10 50% A 1h 6 B 30min 4
| 100% | 4h | Column |
|---|---|---|
| 2h | ||
| 1h | ||
| 30min | ||
| 80% | 4h | |
| 2h | ||
| 1h | ||
| 30min | ||
| 50% | 4h | |
| 2h | ||
| 1h | ||
| 30min |
Source page
Page 6
2.2 Functions of the buttons
Commands Description Result TRANSMISSION OF THE With the device LEDs turned off, press the ⌧ CURRENT WEIGHT. button once to dispatch the current weight. The led
will start flashing indicating that it is waiting for the dispatch confirmation. You will need to press the ⌧ button again to confirm this.
ZERO OPERATION With the device LEDs turned off, press the ⌧ The button led ⌧ will (for system button once to dispatch the zero operation. The flash and fix itself for a adjustment only). led will stay fixed, and the led button ⌧ will start few seconds to indicate that the dispatch has flashing. Indicating that it is waiting for the dispatch been successful. In case confirmation. You will need to press the ⌧ button to that the dispatch was not confirm the dispatch of the frame. possible, the led will not KNOWN WEIGHT With the device LEDs turned off press the ⌧ turn on. OPERATION (for system button once to dispatch the known weight. The adjustment only). led will stay fixed, and the led button ⌧ will start flashing. Indicating that it is waiting for the dispatch confirmation. You will need to press the ⌧ button to confirm the dispatch of the frame. The device will issue a Check the status and number sequence to errors of the device. With the leds of the device turned off, press the indicate the status of the buttons ⌧ and ⌧ at the same time to check the device by turning on all leds. status and errors of the device. For more information, see section 2.3. 2.3 Device status and errors
OK ERROR Blinck code Sensor Device Dispatch
Sensor error 1-1 Poorly connected sensor or load cell, damaged or broken cable, check the 2-1 connections. In case the error persists, you will need to change the sensor. 3-1 Device error 4-1 Impossible to dispatch data. Disconnect and reconnect the battery to your device. 1-2 In case the error persists, you must change the device. 2-2 Dispatch error 3-2 Abusive dispatch use detected. You will have to wait less than 24 hours to 4-2 resume the dispatching. 6
Source page
Page 7
Step by step installation guide
The handling of the device buttons is indicated in Chapter 2.2.
3.1 Device Installation
3.1.1 In case you need to change the power and dispatch time settings, you can select a different mode. For further information, see section 2.1.
3.1.2 When you are at the installation site you must connect the battery to the device. 3.1.3 ⌧ The controlling of these devices will be carried out through the SILOSAPP application. You will need to link the device to the application and consider section 3.1.5 where the place of installation is specified, it is recommended to make a DISPATCH OF THE CURRENT WEIGHT from the location where the device is to be installed, and verify that it has been received correctly by the
application. Otherwise, you must place the device in a clearer area, avoiding possible interference. If the communication is still not possible, you can try connecting the external antenna accessory by placing it at a higher and clearer area. 3.1.4 Once you have verified that the location of the device is valid for communications, you must install the sensor by following the steps in your manual and connect it to the device.
3.1.5 These devices can be installed on the silo leg itself, at an optimal height to access the buttons. You will need to consider the location and leg type of the silo so that the device is located in the clearest part.
3.2 System adjustment
To be able to adjust the device and with the application you will have to follow the following steps:
3.2.1 ⌧ The first step to adjust the system, is to have an empty silo weight reference. To do this, you can wait until the silo is empty or, in the event that the silo is loaded, you must know its approximate weight before performing the ZERO OPERATION. If this occurs, it is recommended to perform the ZERO OPERATION again when the silo is completely empty. In order to have a more precise value. If you have dispatched the ZERO OPERATION with an empty silo, you must configure the SILOSAPP application with a value equal to zero, but if the silo is loaded, you must indicate that load in the application.
3.2.2 ⌧ The second step to adjust the system, is to have a known weight reference. To do this, we will take advantage of the loading of the silo to perform a KNOWN WEIGHT OPERATION. Next, you need to configure the application with the weight value of that load. The value of the load used for the calibration of the silo shall be at least 60% of the total silo capacity.
7 LLAW SILO INSTALLATION PLACE SILO
Source page
Page 8
Dinacell Electrónica S.L. Pol. Ind. Santa Ana C/ El Torno No8 CP 28522 Rivas Vaciamadrid, Madrid, ESPAÑA Tel. (+34) 913 001 435 Fax. (+34) 913 001 645 dinacell@dinacell.com www.dinacell.com