CH-100 Data sheet
Technical reference for CH-100 Data sheet with 3 pages, 1 tables, searchable navigation and precise source-page references.
- Chapters
- 1
- Pages
- 3
- Language
- English
- Format

Complete web edition
The complete manual in one reading flow
Pages follow the exact source order. Searchable text is also available for every page.
Complete document
Pages 1 to 3
Source page
Page 1
www.dinacell.com
CH-100
Pressure sensor for hydraulic
elevators
More information
CH-100 Hydraulic pressure sensor
The hydraulic pressure sensor CH-100 has been developed to measure and control the load of hydraulic elevators. The variations of load in the cabin by the entrance or exit of loads or passengers, turn into variations of pressure that converts the hydraulic pressure line into electrical signals measured our control systems.
The CH-100 occupies minimum space, and is installed in a way that it does not interrupt nor alter the fl ow of the hydraulic fl uid. Installation can be done easily by using a T-adapter connection in any point of the pressure pipeline.
The CH-100 sensor is a robust and compact design that does not aff ect on the reliability of the pressure system. It has a measuring range of 0 to 100 bars, alowing the integration of a load limiter into the elevator or freight lift. The hydraulic sensor has the standard thread for the proper fi tting and adapters are off ered for other measures, allowing so to always have the solution for your installation.
These sensors are factory calibrated, so they can be used directly in an installation without using a known weight to calibrate it.
Pressure pipeline
Hydraulic System Unit Hydraulic cylinder
1/3
Source page
Page 2
CH-100
1/4” NPT
1/4” BSPP
Ø 30 Ø22 9 43 91 34 Datasheet Specifications Parameter Units Specifications Model - CH-100 Nominal Pressure (N.P.) bar 100 Accuracy - <0.4% Maximum excitation voltage V 12 Compensated -10 ... +40 (+14 ... +104) Temperature range Operating oC (oF) -20 ... +60 (-4 ... +140) Storage -20 ... +70 (-4 ... +158) Min. Insulation resistance (V.Test = 100V) GΩ 4 Input resistance Ω 350±1% Output resistance Ω 350±1% Safe 150 Load limit %N.L. Without characteristics loss 200 Type - 4 x 0.22mm2 Ø6 Termination - Wiring connection / USB Cable Standard length m 4 Material - Polyurethane (PU) Material - Alloy steel Sensor Material - Aluminum Casing Surface treatment - Anodized Protection class - IP67 Dimensional drawings (mm) and wiring diagram 1/4” BSPP 1/4” 1/2” BSPP NPT 1/4” 1/2” BSPP BSPT + Exc. Red + Signal Green - Exc. Black - Signal White Shield (GND) 2/3
| - |
|---|
| bar |
| - |
| V |
| oC (oF) |
| GΩ |
| Ω |
| Ω |
| %N.L. |
| - |
| - |
| m |
| - |
| - |
| - |
| - |
| - |
Source page
Page 3
Datasheet CH-100
Product Reference
Ref. Model 000960 CH-100
Accessory: Adapter sleeve
Ref. A 022399 1/4” NPT 013774 1/2” NPT 022401 1/2” BSPT
For more information
www.dinacell.com Certifi ed company Dinacell Electrónica S.L. Pol. Ind. Santa Ana, C/ de la Fundición 8 CP 28522 Rivas Vaciamadrid, Madrid, ESPAÑA Tel. (+34) 913 001 435 Document Ref: D1032-08 Publication Date: 24/04/2026 VMFT06.04
Dinacell Electrónica S.L. reserves the right to add, modify and/or delete content of the document without prior notice. The content indicated here should be used as general product information. It should not be interpreted as a guarantee of quality or durability. 3/3