Page 1
www.dinacell.com
CFRT
Silos Load weighing cell with
anti overturn system
More information
CFRT Bending Load Cell
The CFRT is a load cell specially designed for silos. The anti-roll system makes this cell the best choice for this type of installations. It allows to convert any tank into a scale in order to control the stored load level.
The CFRT’s design includes a casted iron support, with anticorrosion-resistant paint coverage and electrical insulation between the support and the cell, as well as incorporating a ground cable for cell protection from electrical shocks. The upper mounting tolerates any type of support, whether round legged or laminated, regardless of the layout. Its specifi c characteristics ensure the proper safety, performance as well as accuracy.
Accessories for the CFRT
Anchoring bolt... Assembly bolt. This accessory provides aaa solid This set of hardware will help anchoring,,, from the cell base you to attach the cell to the mount to the ground... silos leg.
1/3
Source page
Page 2
CFRT
Ø148
105 83.5
Ø148 Ø118
17 40 30 170 30 230 051 = 811 = 5.38 M-20 M-16 M-16 (4) M-20 (3) 011 74 93 42 02 Datasheet Specifications Parameter Units Specifications Model - CFRT Nominal Load (N.L.) t 1 / 2 / 3 / 4 / 5 / 6 Nominal Sensibility (N.S.) mV/V 2 ± 0.1% Zero balance %N.S. 2 Maximum excitation voltage V 12 Hysteresis error %N.S. 0.033 Crepp, over 30 minutes %N.S. 0.03 Maximum linearity error %N.S. 0.02 Compensated -10 ... +40 (+14 ... +104) Temperature range Operating oC (oF) -20 ... +60 (-4 ... +140) Storage -20 ... +70 (-4 ... +158) Temperature effect on sensibility %N.S. 0.022 Temperature effect on zero % / 5oC 0.018 Min. Insulation resistance (V.Test = 100V) GΩ 4 Input resistance Ω 380 ± 10 Output resistance Ω 350 ± 1.5 Safe 200 Load limit %N.L. Without characteristics loss 150 Type - 4 x 0.22mm2 Ø6 Cable Standard length m 6 Material - Polyurethane (PU) Material - Alloy steel Sensor Surface treatment - Chemical nikel Protection class - IP67 Working on - Bending Beam Dimensional drawings (mm) and wiring diagram 4° 4° M -20 + Exc. Red + Signal Green - Exc. Black - Signal White Shield (GND) 2/3
| - |
|---|
| t |
| mV/V |
| %N.S. |
| V |
| %N.S. |
| %N.S. |
| %N.S. |
| oC (oF) |
| %N.S. |
| % / 5oC |
| GΩ |
| Ω |
| Ω |
| %N.L. |
| - |
| m |
| - |
| - |
| - |
| - |
| - |
Source page
Page 3
Datasheet CFRT
Product Reference
Ref. Nominal Load (N.L.) Model 022518 1 022529 2 023059 3 CFRT 009650 4 013286 5 008774 6
Accessory: Assembly bolt
Parameter Units Threaded rod Hex nut Washer Quantity - 1 1 1 Metric - M20 Dimensions mm 76 - - Surface treatment - Zinc plated Ref. 008469
Accessory: Metal expansion anchor for concrete
Parameter Units Anchory bolt Quantity - 4 Metric mm M12 Ø16x100 Surface treatment - Zinc plated Ref. 008470
For more information
www.dinacell.com Certifi ed company Dinacell Electrónica S.L. Pol. Ind. Santa Ana, C/ de la Fundición 8 CP 28522 Rivas Vaciamadrid, Madrid, ESPAÑA Tel. (+34) 913 001 435 Document Ref: D1090-08 Publication Date: 03/06/2026 VMFT06.04