DinacellData sheet

CDS Data sheet

Technical reference for CDS Data sheet with 3 pages, 2 tables, searchable navigation and precise source-page references.

Chapters
1
Pages
3
Language
English
Format
PDF
CDS Data sheet
First page of the technical document

Complete web edition

The complete manual in one reading flow

Pages follow the exact source order. Searchable text is also available for every page.

1

Complete document

Pages 1 to 3

Source page

Page 1

Open in PDF

www.dinacell.com

CDS

Control panel for silo discharge

More information

CDS Control panel

The CDS control boxes are used to command multiple MLS---FD devices and control its discharge function... These devices must be connected to each other via CAN network. The CDSs allow manual control through their buttons as well as to know the status of the discharge through 3 light indicators. It is possible to automate the system by integrating a level /capacitive sensor that shows when the discharge should be iniciated. These control panels also integrate a contactor that allows you to activate an engine like that of a mixer.

DOSIFICATION CONDITION ON ERROR STOPPED 54321 1987600000 00000 0 M AT4-xL2A0 TR L mM L A AL MonitDor iMneLleSac Stcreóerni T ieclsal 54321 1987600000 00000 0 M AT4-xL2A0 TR L mM L A AL MonitDor iMneLleSac Stcreóerni T ieclsal START PAUSE STOP Compatible with Dinacell SilosApp solution

Some models feature the possibility of sending data from a CAN network to a remote server via GPRS or ETHERNET, depending on the model. This would allow not only the visualization of the weight of each silo, but also the possibility to start and confi gure the discharge, as well as to know its status in real time, via the SilosApp application.

1/3

Source page

Page 2

Open in PDF

CDS

141 821

310.4

052 4.032 Datasheet Specifications Parameter Units Specifications Model - CDS-NC CDS-ETHERNET CDS-GPRS VAC 230 Power supply Hz 50 ... 60 Working -20 ... +60 (-4 ... +140) Temperature range oC (oF) Storage -20 ... +70 (-4 ... +158) Level / capacitive sensor kW Relay output Nominal Power A 4 Inputs & Outputs Contactor Nominal Current - 25 Number of poles - 4 Quectel m95 Quad Band Module - - - (GSM/GPRS/2G) Jamming detection QuecFOTATM Band GSM / EDGE MHz - - 850 / 900 / 1800 / 1900 Wireless connectivity Region - Global CE / GCF / Vodafone / UCRF Approvals - - - / ATEX / PTCRB / FCC / IC / Rogers / NCC / DoC / ICASA Bandwidth Mbps - 10 / 100 - Interface - - RJ45 - Ethernet connectivity Energy Efficient Standard - - Ethernet - (IEEE 802.3az) Maximum number of devices Connectivity BUS-CAN - 8 connected to the CAN network Status indicators - 3 Interface Keys - 3 Casing material - Fireproof V0 Protection class - IP56 Dimensional Drawings (mm) CAN S L E E N V S E O L R ETH MOTOR IN MOTOR OUT 230VAC DOSIFICATION CONDITION ON ERROR STOPPED START PAUSE STOP 2/3

-CDS-NCCDS-ETHERNET
VAC
Hz
oC (oF)
kW
A
-
-
---
MHz--
-
---
Mbps-10 / 100
--RJ45
--Energy Efficient Ethernet (IEEE 802.3az)
-
-
-
-
-

Source page

Page 3

Open in PDF

Datasheet CDS

Product Reference

CDS

CDS-NC CDS-ETHERNET CDS-GPRS 021615 021301 021953

CDS + MLS-FD set

CDS-NC CDS-ETHERNET CDS-GPRS MLS-FD + MLS-FD + MLS-FD + MLS-FD number + 021672 021613 021668 2 021673 021669 021684 3 021674 021670 021712 4 021675 021671 021589 5

For more information

www.dinacell.com Certifi ed company Dinacell Electrónica S.L. Pol. Ind. Santa Ana, C/ de la Fundición 8 CP 28522 Rivas Vaciamadrid, Madrid, ESPAÑA Tel. (+34) 913 001 435 Document Ref: D1868-02 Publication Date: 11/06/2026 VMFT06.04

Dinacell Electrónica S.L. reserves the right to add, modify and/or delete content of the document without prior notice. The content indicated here should be used as general product information. It should not be interpreted as a guarantee of quality or durability. 3/3

021613021668
021669021684
021670021712
021671021589

Technical data

Highlighted specifications

SpecificationValuePage
Mbps- | 10 / 1002