DinacellData sheet

DC LOAD PIN Data sheet

Technical reference for DC LOAD PIN Data sheet with 3 pages, 3 tables, searchable navigation and precise source-page references.

Chapters
1
Pages
3
Language
English
Format
PDF
DC LOAD PIN Data sheet
First page of the technical document

Complete web edition

The complete manual in one reading flow

Pages follow the exact source order. Searchable text is also available for every page.

1

Complete document

Pages 1 to 3

Source page

Page 1

Open in PDF

www.dinacell.com

BULON DC

Load Pins designed and

manufactured to fit any sice

BLP STA2 STA3

More information

The load pins are mainly intended to avoid over weighting, force monitoring, safety and industrial measurement. Its common application is intended for the industrial sector, weighing on cranes, lifting devices, control of conveyor belts, trucks... The principle is based on the replacement of the original pulley shafts, detecting so the force originating in them. The pin signal is adjusted with the throttling equipment, preventing an overload in the structures.

At Dinacell we are specialists in the manufacture of pins, we design them and manufacture them to measure with different diameters and lengths. To fit your workplace correctly, we've divided the pins into three main models based on their IP protection. The models are divided into BLP, STA2 and STA3.

1/3

Source page

Page 2

Open in PDF

Data Sheet BULON DC

Specifications

Parameter Parameter Specifications Model - BLP STA3 STA2 Nominal Load (N.L.) kg ... Estimated accuracy - 1% Hysteresis error %N.L. < 0.07% Crepp, over 30 minutes %N.L. 0.01% Compensated -10 ... +40 (+14 ... +104) Temperature range Operating oC (oF) -20 ... +60 (-4 ... +140) Storage -20 ... +70 (-4 ... +158) Temperature effect on sensibility % / 10oC 0.044 Temperature effect on zero % / 5oC 0.015 Min. Insulation resistance (V.Test = 100V) GΩ 4 Safe 150 Load limit Without characteristics loss %N.L. 200 Breaking >300 Type - 4 x 0.22mm2 Ø5.3 Cable Standard length m 5 Material - Polyurethane (PU) Alloy steel / Stainless Alloy steel / Stainless Material - Stainless Steel Sensor steel steel Surface treatment - Chemical nickel (Only alloy steel) Protection class - IP65 IP66 IP67 Output options and connection diagram

mV/V 4-20 mA 0-10 V Parameter Specifications Parameter Specifications Parameter Specifications Zero balance ±0.1 mV/V Zero balance 3.85 ... 4.15 mA Zero balance 0.15 ... 0.25V Input sensivity 1.0 ± 0.3 Output with Nominal Load 20 ± 0.3 mA Output with Nominal Load 10 ± 0.2V Maximum voltage 12V 24V Power supply 10 ... 40 V Power supply 10 ... 36 V Output impedance 350Ω 700Ω Current consumption < 30 mA Current consumption < 15 mA

Connector connection M-12 connector + Exc. (1) +Vcc M-12 connector (1) +Vcc M-12 connector - Signal (2) N.C. (2) N.C. - Exc. (3) GND 4 1 3 2 (3) GND 4 1 3 2 + Signal (4) 4-20mA (4) 0-10V Shield (GND) Wiring connection + Exc. Red Red - Signal +Vcc 10...30 +Vcc 10...30 N.C. White N.C. White - Exc. GND Black GND Black + Signal 4-20mA Green 0-10V Green Shield (GND)

2/3

-BLPSTA3
kg
-
%N.L.
%N.L.
oC (oF)
% / 10oC
% / 5oC
%N.L.
-
m
-
-Alloy steel / Stainless steelAlloy steel / Stainless steel
-
-IP65IP66
12V
350Ω

Source page

Page 3

Open in PDF

BULON DC

K* A*

www.dinacell.com

Dinacell Electrónica S.L. Pol. Ind. Santa Ana, C/ de la Fundición 8 CP 28522 Rivas Vaciamadrid, Madrid, ESPAÑA Tel. (+34) 913 001 435 20/10/2025 *JØ BØ H* D C E *G Data Sheet Customer Ref. Quantity: Load Pin Head: Model: BLP IP65 protection No STA3 IP66 protection Yes STA2 IP67 protection Other environmental conditions LOADING Nominal Load (N.L.): kg kN lb APPLICATION Material: Alloy steel + nickel plated Stainless Steel Other Signal type: mV/V Maximum voltage 12V 24V MOUNT MOUNT 4-20mA 0-10V F CAN i-C4C Other Note: The dimensions marked with (*) should only be indicated Connection: Wired Standard if they are relevant. They may be modified by Dinacell in case of design or performance improvements. Heat resistant CSA HF Dimensions mm Inches Other A* F With M12 connector ØB Tol. G* Other C H* Redundant output: No D ØJ* Yes 2 Outputs 1 Output E K* Standard length: 5m (standard) Other Note: Default tolerance on ØB = d10. (Other tolerances on Cable position: request). Axial Remarks: Radial Cable termination: With wires (free ends) With connector Grease hole: No Yes For more information Certified company Document Ref: D1101-04 Publication Date: VM05.02 Dinacell Electrónica S.L. reserves the right to add, modify and/or delete content of the document without prior notice. The content indicated here should be used as general product information. It should not be interpreted as a guarantee of quality or durability. 3/3

ColumnColumnLOADING APPLICATIONColumn
MOUNTMOUNT

Related products

Products covered by this document