BTM User manual
Technical reference for BTM User manual with 4 pages, 1 tables, searchable navigation and precise source-page references.
- Chapters
- 1
- Pages
- 4
- Language
- English
- Format

Complete web edition
The complete manual in one reading flow
Pages follow the exact source order. Searchable text is also available for every page.
Complete document
Pages 1 to 4
Source page
Page 1
BTM
User Manual
Dinacell Electrónica S.L.
Source page
Page 2
Introduction
1.1 Product Description
The BTM/RTM sensors are Plug&Play sensors that are part of the tool for checking and adjusting the tension of elevator belts. Its tightening system allows you to install and uninstall the sensors quickly and easily.
1.2 Pre-installation knowledge
The BTM sensors are installed individually on each of the elevator belts. The installation location depending on the type of suspension is indicated in FIGURE 1 and FIGURE 2. The sensors should not be placed less than 30cm from the fi xed point. For the sensors to function correctly, they
must be attached to the tape so that they do not come into contact with any other element. During the measurement with the sensors the elevator must be stopped.
The sensors must be uninstalled before using the elevator normally again.
Installation location depending on the type of suspension:
FIGURE 1 FIGURE 2
Sensor Sensor installation installation
Installation with 1:1 suspension Installation with 2:1 suspension Minimum distance: 30cm (11,811inches) 1 on knowledge talled individually on each of the lation location depending on the dicated in FIGURE 1 and FIGURE ot be placed less than 30cm from ensors to function correctly, they tape so that they do not come her element. t with the sensors the elevator nstalled before using the elevator ending on the type of suspension: FIGURE 2 Minimum distance: 30cm (11,811inches) Plug & Play Factory adjusted
Source page
Page 3
Introduction
1.3 Main technical characteristics
Parameter Units Technical specifications Model - BTM Specifications with Nominal Load (N.L.) kg 380 740 400 500 640 800 980 a belt tension Maximum workload - 150% measurement device Accuracy - 1% Minimum Breakage Load kN 32 64 34 43 52 68 85 Belt specifications Width 30 60 25 30 36 38 48 mm Thickness 3 3.3 4.6 Maximum excitation voltage V 12 Compensated -10 ... +40 (+14 ... +104) Temperature range Operating °C (°F) -20 ... +60 (-4 ... +140) Storage -20 ... +70 (-4 ... +158)
1.4 Sensor dimensions and components
91.9 78 23 30 38.9 32.5 30
1 60
Components
(1) Pressure point (2) Clamps (3) Pressure lever 4 (4) Usb connector 571 27 27 5.81 1 a belt tension measurementdevice Belt specifications Maximum excitation vo Temperature range 1.4 Sensor 23 571 27
| - | Column | Column | Column | Column | Column | Column |
|---|---|---|---|---|---|---|
| kg | 380 | 740 | 400 | 500 | 640 | 800 |
| - | ||||||
| - | ||||||
| kN | 32 | 64 | 34 | 43 | 52 | 68 |
| mm | 30 | 60 | 25 | 30 | 36 | 38 |
| 3 | 3.3 | |||||
| V | ||||||
| °C (°F) |
Source page
Page 4
Step by step installation
2.1 Steps to install a BTM sensor
1 2
The fi rst step is to connect all the sensors to the equipment. Once the sensors are connected to the equipment, check The next step is to place the sensors on the tape. To do this the manual of said equipment if you have to make any you must lift the pressure lever. type of confi guration adjustments.
3 4
Insert the sensor by placing the tape between the pressure Finally, secure the sensor by lowering the pressure lever. point and the clamps.
For more information www.dinacell.com
Dinacell Electrónica S.L. Pol. Ind. Santa Ana C/ El Torno No8 CP 28522 Rivas Vaciamadrid, Madrid, ESPAÑA Tel. (+34) 913 001 435
Once the belt tension has been adjusted, you must uninstall the sensor to use the elevator normally again. To do this, perform the Document Ref: D2273-00 steps indicated above in reverse. Publication Date: 27/12/2023
Technical data
Highlighted specifications
| Specification | Value | Page |
|---|---|---|