BPSXR

Sensor designed for the

terminals fi xed point

More information

BPSXR Compression load cell

The BPSXR load cells are a weighing solution at the fi xed point of cables in traction elevators.

The advantages of the new design of the BPSXR sensor are as follows: - This sensor has a low profi le that improves weighing accuracy. - A new geometric design, for perfect stability when weighing at all angles. - Space saving and a lower height sensor. - No need to add washers to the installation. - Aff ordable with a competitive price.

For a complete installation

These sensors are installed at the fi xed point and feature a USB cable output. In order to have an independent reading of the weight of each cable, we recommend the use of our OMEGA device.

For installations that need to connect a set of sensors to a load limiter, with a single input, it is necessary to combine the signal in a single output by using a (1) INTERFACE. These accessories off er cable output without connector or WITH USB (depending on the type of input of the limiting device).

1. INTERFACE

1/3

Source page

Page 2

Open in PDF

BPSXR

Ø20

61 2 41

24 Datasheet Specifications Parameter Units Specifications Model - BPSXR Nominal Load (N.L.) kg 5300 Accuracy - 1% Maximum excitation voltage V 12 Compensated -10 ... +40 (+14 ... +104) Temperature range Operating oC (oF) -20 ... +60 (-4 ... +140) Storage -20 ... +70 (-4 ... +158) Min. Insulation resistance (V.Test = 100V) GΩ >4 Input resistance Ω 350 Output resistance Ω 350 Without characteristics loss 150 Load limit %N.L. Breaking >250 Type - 4 x 0.14mm2 Ø4.3 Termination - USB Cable Standard length m 2.5 Material - Polyurethane (PU) Material - Aluminum Sensor Surface treatment - Anodized Protection class - IP62 Dimensional drawings (mm) and wiring diagram Ø14.5 M4 8 Ø48 + Exc. + Signal - Exc. - Signal Shield (GND) 2/3

-
kg
-
V
oC (oF)
Ω
Ω
%N.L.
-
-
m
-
-
-
-

Source page

Page 3

Open in PDF

www.dinacell.com

Dinacell Electrónica S.L. Pol. Ind. Santa Ana, C/ de la Fundición 8 CP 28522 Rivas Vaciamadrid, Madrid, ESPAÑA Tel. (+34) 913 001 435 15/04/2026 5.32 24 Datasheet BPSXR Product Reference Ref. Model 026872 BPSXR Accessory: INTERFACE 4 Parameter Units Specifi cations Model - INTERFACE 16.2 A Temperature range oC (oF) -20 ... +60 (-4 ... +140) B Casing material - Fireproof V0 C Protection class - IP50 Cable type - 4 x 0.22mm2 Ø4 Standard length m 5 + Ferrita Dimensions in mm USB Input - 6 12 USB A B C Wiring Wiring Cable Output - USB USB connection connection 6 48 69 74 Ref. - 007555 007274 007554 007275 12 84 105 110 For more information Certifi ed company Document Ref: D2277-02 Publication Date: VMFT06.04 Dinacell Electrónica S.L. reserves the right to add, modify and/or delete content of the document without prior notice. The content indicated here should be used as general product information. It should not be interpreted as a guarantee of quality or durability. 3/3