DinacellData sheet

BPP / BPP-CB Data sheet

Technical reference for BPP / BPP-CB Data sheet with 3 pages, 3 tables, searchable navigation and precise source-page references.

Chapters
1
Pages
3
Language
English
Format
PDF
BPP / BPP-CB Data sheet
First page of the technical document

Complete web edition

The complete manual in one reading flow

Pages follow the exact source order. Searchable text is also available for every page.

1

Complete document

Pages 1 to 3

Source page

Page 1

Open in PDF

www.dinacell.com

BPP

Load cells designed to be installed

under the motor bed frame

More information

BPP Compression load cell

The BPP load cell is specially designed to be installed under the motor bed frame. Dinacell has developed two diff erent variants:::

· The BPP is installed supporting the motor weigh. ··· The BPP---CB supports the motor weight and is bolted to the motor shaft.

The Load cells feature aaa silent---block,,, avoiding so possible vibration transmissions... We highly recommend installing at least two load cells,,, placed on the points with the highest pressure,,, obtaining so the best load weighing accuracy.

1/3

Source page

Page 2

Open in PDF

BPP

Ø46

Ø46

140 110

Ø8.5

Ø46

Ø118 02 01 2 21 05 01 02 01 03 011 03 04 041 Datasheet Specifications Parameter Units Specifications Model - BPP BPP-CB Nominal Load (N.L.) t 1.5 / 3 / 5 / 6.5 Nominal Sensibility (N.S.) mV/V 1.4 ... 2.0 Accuracy - 0.2% Zero balance mV/V ± 0.20 Maximum excitation voltage V 12 Compensated -10 ... +40 (+14 ... +104) Temperature range Operating oC (oF) -20 ... +60 (-4 ... +140) Storage -20 ... +70 (-4 ... +154) Min. Insulation resistance (V.Test = 100V) GΩ 4 Input resistance Ω 350 ±3 Output resistance Ω 350 ±2 Safe 150 Load limit %N.L. Breaking >300 Type - 4 x 0.22mm2 Ø6 Cable Standard length m 4 Material - Polyurethane (PU) Material - Alloy steel Sensor Surface treatment - Chemical nickel Protection class - IP67 Dimensional drawings (mm) and wiring diagram BPP SILENTBLOCK NUT M-12 LONG SCREW ALLEN M12 BPP-CB SILENTBLOCK + Exc. Red + Signal Green - Exc. Black - Signal White Shield (GND) 2/3

-BPP
t
mV/V
-
mV/V
V
oC (oF)
Ω
Ω
%N.L.
-
m
-
-
-
-

Source page

Page 3

Open in PDF

Datasheet BPP

Product Reference

Ref. Nominal Load (N.L.) Model 000964 1.5 000973 3 BPP 000369 5 001351 6.5

Ref. Nominal Load (N.L.) Model 009841 1 001906 1.5 000987 3 BPP-CB 001018 5 013141 6.5

For more information

www.dinacell.com Certifi ed company Dinacell Electrónica S.L. Pol. Ind. Santa Ana, C/ de la Fundición 8 CP 28522 Rivas Vaciamadrid, Madrid, ESPAÑA Tel. (+34) 913 001 435 Document Ref: D1022-07 Publication Date: 24/03/2026 VMFT06.06

Dinacell Electrónica S.L. reserves the right to add, modify and/or delete content of the document without prior notice. The content indicated here should be used as general product information. It should not be interpreted as a guarantee of quality or durability. 3/3

1.5
3
5
6.5
1
1.5
3
5
6.5