DC Decoupler F

SCHAEFER products

DC Decoupler F

#SCHAEFER#elevator display#dc decoupler f#elevator control element

The DC Decoupler is connected upstream the Rainbow Button type RB 42 2M XI. In normal operation, the emergency call button thus runs via the standard power supply. In case of a power failure the emergency call button will be fed via the emergency power supply.

Product information

Official manufacturer details

The DC Decoupler is connected upstream the Rainbow Button type RB 42 2M XI. In normal operation, the emergency call button thus runs via the standard power supply. In case of a power failure the emergency call button will be fed via the emergency power supply.

For the permanent display of elevator data , the DC Decoupler can be connected. Thus, the normal operation of the TFT display runs via the standard power supply. In case of a power failure it will be fed via the emergency power supply.

The emergency and standard power supply remains galvanically separated when the DC Decoupler is employed.



Order no.

Designation

1005560

DC Decoupler F (Set)

1005566

DC Decoupler F mounting set

Specifications

Fixing
Adhesive fixingStandard
Installation depth9.15 mm
Connectivity
Spring pressure terminal0.2 – 1.0 mm²
Electrical data
Power supply U BAT IN (smoothed)12 – 30 V DC
Supply voltage U IN (smoothed)20 – 30 V DC
Supply voltage U OUT24 V DC
Power consumptionmax. 10 W
Current consumption (24 V BAT IN + EL active)15 – 490 mA
Current consumption (24 V BAT IN + EL inactive)≤ 6 mA
Output current (total + EL active)max. 410 mA
Output current (EL OUT)max. 90 mA
Polarity
Common anode or common cathodeX
Other
Temperature range0 – +65 °C
Compliance
Protection classIII SELV