Control Panel
Delta Elevator Control Panel
Features • 24-hour service and support • The floor bypass system through the encoder without the need to arrange the bypass magnet • Ability to cancel summons inside the cabin by tapping the summon thumb twice • Flashing display of floor…
Product information
Specifications
Features
• 24-hour service and support
• The floor bypass system through the encoder without the need to arrange the bypass magnet
• Ability to cancel summons inside the cabin by tapping the summon thumb twice
• Flashing display of floor summons in the cabin
• Showing the number of starters by classes
• Turning on the well light in the revision mode automatically without the need to go to the engine room
• Detecting the presence of a bridge in the safety series circuit and announcing the error and lack of service until the bridge is removed
• The possibility of defining the start limit for the elevator in software in the setting menu
• The possibility of defining the operation logic of panel inputs (close NC or open NO) in software
• Detection of jamming of the thumbs of summons
• Protection of the input of summoning thumbs against 24V voltage connection
• Setting working hours for the floor announcement system (turning off the announcement system at night)
• The ability to set the folder to play different music on occasions
• Possibility of soft stop in revision
• The ability to move slowly at the beginning of the revision to adjust the level of floors
• Has feedback from all contactors to ensure that the contactor is taken or released for greater safety
• It has a test operation mode (Test Mode) to disable the call out and also not to open the cabin door when the elevator is in the startup or adjustment stage (for example, drive adjustment).
• The possibility of disabling the contactor feedback check temporarily in order to continue servicing the elevator for those cases where it is not possible to replace the contactor at the moment or its replacement must be postponed to a certain time (for example, after office hours).
• It has a direction display effect for accurate information about the movement of the elevator:
Elevator in stop mode: turning off the direction arrow or displaying it permanently
Moving elevator: show the flashing direction arrow
Movement speed: changing the flashing speed of the direction arrow according to the movement speed of the elevator
Technical specifications
• In accordance with the EN 81 standard
• Up to 32 collective-selective stops
• CAN serial communication
• The need for 14 strands of trawl wire
• Position control system through encoder
• Support for 2 fully automatic doors
• Has phase one firefighting status
• Intelligent short floor detection
• Has an emergency rescue system (using the drive to move the engine for greater safety)
Ability to open the door before reaching the floor (Advanced Door Opening)
• Record the date and time of the last 50 errors
• Record the number of occurrences of each error
• Record the number of errors that occurred in each floor
• Has an indicator on the main board to announce the error
• Separate messages and errors to inform the work service of the reason for the failure
• Fault detection in different parts of the safety series including: well safety circuit, hinged door contact, step switch on the cabin, parachute, cabin door contact, fully automatic door contact or hinged door lock contact
• View the status of all inputs and outputs on the panel display for easy troubleshooting
• The possibility of changing setting parameters without the need to reset or turn off and on the board
• Has 2 levels of access for settings with two different passwords
• Ability to connect to the intelligent building management system (BMS)
• Has 3 programmable inputs and 2 outputs